纯黏液性乳腺癌的影像学特征:与细胞外黏液含量的相关性
回顾性分析25例纯黏液性乳腺癌(PMBC)的超声、超声弹性成像、乳腺X线和乳腺专用γ成像特征与细胞外黏液含量的相关性。超声上黏液含量与回声模式和彩色多普勒血流显著相关,超声弹性成像上黏液含量与肿瘤硬度呈中度负相关(r=-0.60,p=0.029),乳腺专用γ成像上黏液含量与病灶/非病灶放射性计数比值呈强负相关(r=-0.92,p=0.001);乳腺X线特征与黏液含量无显著相关性(均p>0.05)。
要点
- 乳腺专用γ成像的病灶/非病灶比值与细胞外黏液含量呈强负相关(r=-0.92,p=0.001),为最相关特征。
- 超声弹性成像上黏液含量与肿瘤硬度呈中度负相关(r=-0.60,p=0.029)。
- 超声上黏液含量越低,肿瘤越可能表现为等回声和高血流(回声模式p=0.042,彩色多普勒血流p=0.032)。
核心结论
- 超声、超声弹性成像和乳腺专用γ成像的影像特征与纯黏液性乳腺癌的细胞外黏液含量相关,其中乳腺专用γ成像的病灶/非病灶比值是最相关的特征。
研究设计与样本
- 回顾性研究,纳入25例患者的25个纯黏液性乳腺癌肿瘤;超声、超声弹性成像、乳腺X线和乳腺专用γ成像分别有25、15、11和8例患者可用;以组织学评估的细胞外黏液含量为参考,采用线性趋势卡方检验或Spearman秩相关分析影像特征与黏液含量的相关性。
关键影像表现/征象
- 超声上,黏液含量较低的肿瘤更可能表现为等回声和高血流(回声模式p=0.042,彩色多普勒血流p=0.032)。
- 超声弹性成像上,黏液含量与肿瘤硬度呈中度负相关(r=-0.60,p=0.029)。
- 乳腺专用γ成像上,黏液含量与病灶/非病灶放射性计数比值呈强负相关(r=-0.92,p=0.001)。
- 乳腺X线影像特征与黏液含量无显著相关性(均p>0.05)。
诊断标准与关键数值
- 超声回声模式与黏液含量显著相关(p=0.042)。
- 超声彩色多普勒血流与黏液含量显著相关(p=0.032)。
- 超声弹性成像肿瘤硬度与黏液含量中度负相关(r=-0.60,p=0.029)。
- 乳腺专用γ成像病灶/非病灶比值与黏液含量强负相关(r=-0.92,p=0.001)。
- 乳腺X线影像特征与黏液含量无显著相关性(均p>0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To analyse the correlation between imaging features using multiple techniques and extracellular mucus content in pure mucinous breast carcinoma (PMBC).
MATERIALS AND METHODS: A retrospective review of available images from 25 patients with 25 PMBC tumours was conducted, with ultrasonography (US), ultrasonic elastography (USE), mammography, and breast-specific gamma imaging (BSGI) available for 25, 15, 11, and eight patients, respectively. Microscopic slides from each tumour were evaluated for extracellular mucus content. The correlation between imaging features and mucus content was analysed using linear-by-linear association chi-square tests or Spearman's rank correlation analyses.
RESULTS: On US images, a significant correlation was found between mucus content and echo pattern (p=0.042) and colour Doppler blood flow (p=0.032), with a trend that the lower mucus content present in tumours, the more likely they were detected with isoechoic echo and high blood flow. On USE images, a moderate negative correlation (r=-0.60, p=0.029) was observed between mucus content and tumour stiffness. On BSGI images, a strong negative correlation (r=-0.92, p=0.001) was shown between mucus content and lesion to non-lesion ratio (L/N) values of radioactivity counts. No significant correlation was found between mucus content and mammography imaging features (all p>0.05).
CONCLUSION: Imaging features at US, USE, and BSGI correlated with extracellular mucus content in PMBC tumours, among which the L/N value using BSGI imaging is the most relevant feature.
引用
- Wang PL, Zheng FY, Lu Q, et al. Imaging features of pure mucinous breast carcinoma: correlation with extracellular mucus content. Clin Radiol. 2019. PMID: 30967244. doi:10.1016/j.crad.2019.01.031