乳腺癌筛查中「全」与「快速」MRI 检查活动时间比较
研究比较了70例次加速乳腺MRI(AB-MR)与736例次全方案MRI筛查的活动时间。AB方案实际扫描时间17.5±0.5分钟,全方案28.8±0.3分钟(差值11.3分钟,P<.0001);总检查时间分别为36.0±3.2分钟与49.7±0.8分钟(差值13.7分钟,P<.0001)。患者流通量仅提高38%,低于基于扫描时间预期的65%,原因是AB-MR方案技师活动时间增加。
要点
- AB-MR实际扫描时间17.5分钟,较全方案28.8分钟缩短11.3分钟(P<.0001)。
- AB-MR总检查时间36.0分钟,较全方案49.7分钟缩短13.7分钟(P<.0001)。
- 患者流通量仅提高38%,低于扫描时间预期的65%,因技师活动时间增加。
核心结论
- AB-MR方案实际扫描时间较全方案缩短11.3分钟,总检查时间缩短13.7分钟,但患者流通量仅提高38%,低于基于扫描时间预期的65%,原因是AB-MR方案技师活动时间增加。
研究设计与样本
- 比较新实施的加速乳腺MRI(AB-MR)筛查方案与全方案检查的活动时间,分析70例次AB-MR与736例次全方案MRI筛查研究;总检查时间从开检到关检测量,预期扫描时间通过累加各序列采集时间获得,实际扫描时间取自DICOM头信息,技师活动时间由总检查时间减去预期扫描时间获得,包含扫描相关与非扫描相关活动。
诊断标准与关键数值
- AB方案实际扫描时间17.5±0.5分钟,全方案28.8±0.3分钟(均值±标准误),差值11.3分钟,P<.0001。
- AB-MRI总检查时间36.0±3.2分钟,全方案49.7±0.8分钟,差值13.7分钟,P<.0001。
- AB-MR方案患者流通量较全方案仅提高38%,低于基于扫描时间预期的65%。
临床应用与阅片要点
- 评估快速MRI筛查流程效率时,需同时考虑技师活动时间,仅依据扫描时间会高估患者流通量的提升。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To optimize operations for a newly implemented abbreviated MR (AB-MR) breast cancer screening protocol, activity times were compared with the full-protocol examination.
METHODS: Activity times from 70 AB-MR and 736 full MR screening studies were analyzed. Total study time was measured from opening to closing examinations and expected scan time by summing the time of acquisition for each imaging series for either protocol. Actual scan time was obtained from DICOM headers. Total technologist activity time was obtained by subtracting expected scan time from total study time. Technologist activity time included both scan-related and non-scan-related activities.
RESULTS: The actual scan time for the AB protocol was 17.5 ± 0.5 min, compared with 28.8 ± 0.3 min (mean ± SE) for the full protocol (difference, 11.3 min; P < .0001). The total study time was 36.0 ± 3.2 min for AB-MRI and 49.7 ± 0.8 min for the full protocol (difference, 13.7 min; P < .0001), implying that the AB-MR protocol had only a 38% greater patient flow rate than the full protocol.
CONCLUSIONS: The realized gains in patient flow rate were lower than expected based on scan times (65%) because of increased technologist activity time for the AB-MR protocol.
引用
- Borthakur A, Weinstein SP, Schnall MD, et al. Comparison of Study Activity Times for "Full" versus "Fast MRI" for Breast Cancer Screening. J Am Coll Radiol. 2019. PMID: 30975607. doi:10.1016/j.jacr.2019.01.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。