文献速递妇产影像泌尿生殖MR

3 T 磁共振波谱、扩散加权成像及表观扩散系数值鉴别子宫肌层肿瘤良恶性的诊断价值

Diagnostic value of 3 T MR spectroscopy, diffusion-weighted MRI, and apparent diffusion coefficient value for distinguishing benign from malignant myometrial tumours.
PubMed 文献 · Clin Radiol · 2019-04-20

研究纳入14例患者的21个子宫肉瘤和51例患者的84个良性平滑肌瘤,在3 T MRI上评估DWI和MRS鉴别良恶性的效能。恶性病变100%显示扩散受限而良性平滑肌瘤仅5%,联合ADC与MRS获得98.3%(95%CI 95.1-100)的准确率。作者认为DWI联合MRS可能有助于术前鉴别良性平滑肌瘤与平滑肌肉瘤。

要点

  • 恶性子宫病变100%见扩散受限,良性平滑肌瘤仅5%见扩散受限。
  • 恶性病变出现胆碱峰和脂质峰的比例显著高于良性病变。
  • 联合ADC与MRS鉴别良恶性准确率达98.3%(95%CI 95.1-100)。

核心结论

  • DWI联合MRS可能有助于术前评估子宫肿块,鉴别良性平滑肌瘤与平滑肌肉瘤。

研究设计与样本

  • 研究纳入14例患者的21个子宫肉瘤和51例患者的84个良性平滑肌瘤,使用3 T MRI系统采集T1WI、T2WI和DWI,约60%患者同时行MRS,以病理为参考标准。

关键影像表现/征象

  • DWI视觉评估显示恶性病变100%表现为扩散受限,良性平滑肌瘤仅5%表现为扩散受限。
  • 恶性病变的平均ADC值显著低于良性病变(p<0.001)。
  • 恶性病变出现胆碱峰和脂质峰的比例显著高于良性病变。

诊断标准与关键数值

  • DWI视觉评估扩散受限:恶性病变100%,良性平滑肌瘤5%。
  • 恶性病变平均ADC值显著低于良性病变(p<0.001)。
  • 联合ADC与MRS鉴别良恶性的准确率为98.3%(95%CI 95.1-100)。

临床应用与阅片要点

  • 阅片时可结合DWI扩散受限表现和ADC值评估子宫肌层肿瘤良恶性。
  • 对约60%行MRS的患者,胆碱峰和脂质峰有助于提高鉴别特异性。
  • 作者认为DWI联合MRS可能有助于术前鉴别良性平滑肌瘤与平滑肌肉瘤。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To further verify the effectiveness of diffusion-weighted (DWI) magnetic resonance imaging (MRI) and 1H magnetic resonance spectroscopy (MRS) using a 3 T MRI system to differentiate benign leiomyomas from uterine sarcoma; to investigate the benefit of adding MRS to the apparent diffusion coefficient (ADC) for improving the specificity of the benign/malignant classification.

MATERIALS AND METHODS: The dataset included 21 uterine sarcoma from 14 patients and 84 benign leiomyomas from 51 patients. T1-and T2-weighted images as well as DWI were obtained using a 3-T MRI system. Approximately 60% of patients also underwent MRS. The chi-square test was used to compare the percentage of malignant lesions that showed choline peaks, lipid peaks, and restricted diffusion to the corresponding percentage of benign masses. Using the area under a receiver operating characteristic (AUC) curve, the efficacy of different parameters for distinguishing uterine sarcomas from leiomyomas was measured.

RESULTS: The visual assessment of DWI images showed that 100% of malignant lesions exhibited restricted diffusion while the corresponding figure for benign leiomyomas was only 5%. The mean ADC of malignant tumours differed significantly from that of benign ones (p<0.001). The percentage of malignant lesions for which choline and lipid peaks were present was significantly higher than that of benign lesions. By combining the ADC and MRS findings, an accuracy of 98.3 (95.1-100) was achieved.

CONCLUSIONS: The findings suggested that a combination of DWI and MRS could be useful in the preoperative assessment of uterine masses to differentiate benign leiomyomas from leiomyosarcoma.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Rahimifar P, Hashemi H, Malek M, et al. Diagnostic value of 3 T MR spectroscopy, diffusion-weighted MRI, and apparent diffusion coefficient value for distinguishing benign from malignant myometrial tumours. Clin Radiol. 2019. PMID: 31010584. doi:10.1016/j.crad.2019.03.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。