文献速递妇产影像儿科影像US

结构异常双胎中经核型分析和微阵列分析检出的染色体异常

Chromosomal abnormalities detected by karyotyping and microarray analysis in twins with structural anomalies.
PubMed 文献 · Ultrasound Obstet Gynecol · 2020-02-28

单中心回顾性分析11年间534例双胎妊娠,其中至少一胎超声诊断结构异常。549个结构异常胎儿中432个(78.7%)获得侵入性产前诊断细胞遗传学结果。双绒毛膜双羊膜囊(DCDA)胎儿总体染色体异常发生率(25.4%)高于单绒毛膜单羊膜囊(MCMA,3.7%)和单绒毛膜双羊膜囊(MCDA,15.3%)。DCDA组非整倍体发生率(22.8%)显著高于MCMA组(0.0%)和MCDA组(12.4%)。染色体微阵列分析(CMA)在5个(2.0%;95%CI 0.3-3.7%)DCDA胎儿中检出核型分析无法发现的致病性拷贝数变异(CNV),MCMA和MCDA双胎中未发现致病性CNV。

要点

  • 结构异常双胎中,DCDA胎儿总体染色体异常发生率25.4%,高于MCDA的15.3%和MCMA的3.7%。
  • DCDA组非整倍体发生率22.8%,显著高于MCMA组0.0%和MCDA组12.4%。
  • DCDA和MCDA组中,胎儿水肿均与最高染色体异常发生率相关,其中67.6%为Turner综合征(45,X)。

核心结论

  • 结构异常的双绒毛膜双胎染色体异常风险高于单绒毛膜双胎,尤其非整倍体;CMA在双胎中较核型分析的额外诊断增益似乎低于单胎妊娠中报告的增益(2.0%)。

研究设计与样本

  • 单中心回顾性分析,纳入11年间534例双胎妊娠,其中一胎或两胎超声诊断先天性结构异常;双胎按绒毛膜性和羊膜性分为MCMA(25对)、MCDA(112对)和DCDA(397对);549个结构异常胎儿中432个(78.7%)获得侵入性产前诊断G显带核型分析和/或CMA的细胞遗传学结果。

诊断标准与关键数值

  • DCDA胎儿总体染色体异常发生率25.4%,MCMA为3.7%,MCDA为15.3%。
  • DCDA组非整倍体发生率22.8%,显著高于MCMA组0.0%和MCDA组12.4%。
  • DCDA组心血管、面颈部、骨骼肌肉、泌尿生殖和胃肠系统异常胎儿的染色体异常发生率高于MCDA组。
  • DCDA和MCDA组中胎儿水肿与最高染色体异常发生率相关,其中67.6%为Turner综合征(45,X)。
  • CMA在5个(2.0%;95%CI 0.3-3.7%)DCDA胎儿中检出核型分析无法发现的致病性CNV;MCMA和MCDA双胎中未发现致病性CNV。

临床应用与阅片要点

  • 超声检出双胎结构异常时,应结合绒毛膜性和羊膜性评估染色体异常风险,DCDA双胎风险高于单绒毛膜双胎。
  • DCDA和MCDA双胎中,胎儿水肿与最高染色体异常发生率相关,其中67.6%为Turner综合征(45,X)。
  • 在双胎中,CMA较核型分析的额外诊断增益似乎低于单胎妊娠中报告的增益(2.0%)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the incidence and types of chromosomal abnormalities detected in twins with structural anomalies and compare their distribution according to chorionicity and amnionicity and by structural-anomaly type. The added value of chromosomal microarray analysis (CMA) over conventional karyotyping in twins was also estimated.

METHODS: This was a single-center, retrospective analysis of 534 twin pregnancies seen over an 11-year period, in which one or both fetuses were diagnosed with congenital structural anomalies on ultrasound. The ultrasound findings and invasive prenatal diagnostic results were reviewed. Twin pregnancies were categorized as monochorionic monoamniotic (MCMA), monochorionic diamniotic (MCDA) or dichorionic diamniotic (DCDA). Chromosomal abnormalities detected by G-banding karyotyping and/or CMA were analyzed by chorionicity and amnionicity and by structural-anomaly type.

RESULTS: The 534 twin pairs analyzed comprised 25 pairs of MCMA, 112 pairs of MCDA and 397 pairs of DCDA twins. Of the 549 fetuses affected by structural anomalies, 432 (78.7%) underwent invasive prenatal testing and cytogenetic results were obtained. The incidence of overall chromosomal abnormalities in the DCDA fetuses (25.4%) was higher than that in the MCMA (3.7%) and MCDA (15.3%) fetuses. The incidence of aneuploidy was significantly higher in the DCDA group (22.8%) than in the MCMA (0.0%) and MCDA (12.4%) groups. The incidence of chromosomal abnormalities detected in fetuses, with anomalies of the cardiovascular, faciocervical, musculoskeletal, genitourinary and gastrointestinal systems, was higher in the DCDA group than in the MCDA group. In both the DCDA and MCDA groups, hydrops fetalis was associated with the highest incidence of chromosomal abnormality; of these fetuses, 67.6% had Turner syndrome (45,X). Pathogenic copy-number variations (CNVs) undetectable by karyotyping were identified by CMA in five (2.0%; 95% CI, 0.3-3.7%) DCDA fetuses. No pathogenic CNVs were found in MCMA and MCDA twins.

CONCLUSIONS: Dichorionic twins with structural anomalies have a higher risk of chromosomal abnormalities, especially aneuploidies, than do monochorionic twins. The incremental diagnostic yield of CMA over karyotyping seems to be lower (2.0%) in twins than that reported in singleton pregnancy. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Li L, He Z, Huang X, et al. Chromosomal abnormalities detected by karyotyping and microarray analysis in twins with structural anomalies. Ultrasound Obstet Gynecol. 2020. PMID: 30977228. doi:10.1002/uog.20287

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。