文献速递妇产影像泌尿生殖US

妇科疾病的影像学(16):附件浆液性囊腺纤维瘤的临床与超声特征

Imaging in gynecological disease (16): clinical and ultrasound characteristics of serous cystadenofibromas in adnexa.
PubMed 文献 · Ultrasound Obstet Gynecol · 2019-01-01

回顾性分析国际卵巢肿瘤分析(IOTA)数据库1999至2012年间233例经组织学确诊的附件浆液性囊腺纤维瘤,术前均由经验丰富的超声医师检查。IOTA数据库中67.4%表现为含实性成分,52.4%见乳头状突起,其中79.5%乳头状突起内无彩色多普勒血流信号,83.7%肿瘤无或仅少量血流信号。对201幅图像行模式识别分析识别出10种主要超声表现,最常见为单房实性囊肿伴一个或多个乳头状突起但无其他实性成分(25.9%)。

要点

  • 浆液性囊腺纤维瘤超声表现多样,最常见为单房实性囊肿伴乳头状突起且乳头内无血流信号。
  • 多数肿瘤(83.7%)彩色多普勒无或仅少量血流信号,乳头状突起内多无血流(79.5%)。
  • 模式识别分析中39.8%肿瘤可见声影,38.6%含乳头状突起者乳头呈微囊状外观。

核心结论

  • 浆液性囊腺纤维瘤超声特征多样,最常见为单房实性囊肿伴一个或多个乳头状突起但无其他实性成分,彩色多普勒无血流信号;多数肿瘤血供稀少,不少可见声影。

研究设计与样本

  • 回顾性研究,从国际卵巢肿瘤分析(IOTA)前瞻性数据库中识别1999至2012年间经组织学确诊为浆液性囊腺纤维瘤且术前由经验丰富超声医师检查的患者,共233例;另由三位作者先独立后共同对201幅超声图像行模式识别分析。

关键影像表现/征象

  • IOTA数据库中67.4%(157/233)描述为含实性成分,19.3%(45/233)为多房囊肿,13.3%(31/233)为单房囊肿。
  • 52.4%(122/233)可见乳头状突起,其中79.5%(97/122)乳头状突起内无彩色多普勒血流信号。
  • 83.7%(195/233)肿瘤无或仅少量彩色多普勒血流信号。
  • 模式识别分析201幅图像识别出10种主要超声表现,最常见为单房实性囊肿伴一个或多个乳头状突起但无其他实性成分(25.9%,52/201)。
  • 第二常见为多房实性肿块伴小实性成分但无乳头状突起(19.4%,39/201),第三、四位为多房或双房囊肿(16.9%,34/201)与单房囊肿(11.9%,24/201)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To describe the clinical and ultrasound characteristics of serous cystadenofibromas in the adnexa.

METHODS: This was a retrospective study of patients identified in the International Ovarian Tumor Analysis (IOTA) database, who had a histological diagnosis of serous cystadenofibroma and had undergone preoperative ultrasound examination by an experienced ultrasound examiner, between 1999 and 2012. In the IOTA database, which contains data collected prospectively, the tumors were described using the terms and definitions of the IOTA group. In addition, three authors reviewed, first independently and then together, ultrasound images of serous cystadenofibromas and described them using pattern recognition.

RESULTS: We identified 233 women with a histological diagnosis of serous cystadenofibroma. In the IOTA database, most cystadenofibromas (67.4%; 157/233) were described as containing solid components but 19.3% (45/233) were described as multilocular cysts and 13.3% (31/233) as unilocular cysts. Papillary projections were described in 52.4% (122/233) of the cystadenofibromas. In 79.5% (97/122) of the cysts with papillary projections, color Doppler signals were absent in the papillary projections. Most cystadenofibromas (83.7%; 195/233) manifested no or minimal color Doppler signals. On retrospective analysis of 201 ultrasound images of serous cystadenofibromas, using pattern recognition, 10 major types of ultrasound appearance were identified. The most common pattern was a unilocular solid cyst with one or more papillary projections, but no other solid components (25.9%; 52/201). The second most common pattern was a multilocular solid mass with small solid component(s), but no papillary projections (19.4%; 39/201). The third and fourth most common patterns were multi- or bilocular cyst (16.9%; 34/201) and unilocular cyst (11.9%; 24/201). Using pattern recognition, shadowing was identified in 39.8% (80/201) of the tumors, and microcystic appearance of the papillary projections was observed in 34 (38.6%) of the 88 tumors containing papillary projections.

CONCLUSIONS: The ultrasound features of serous cystadenofibromas vary. The most common pattern is a unilocular solid cyst with one or more papillary projections but no other solid components, with absent color Doppler signals. Most serous cystadenofibromas were poorly vascularized on color Doppler examination and many manifested acoustic shadowing. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Virgilio BA, De Blasis I, Sladkevicius P, et al. Imaging in gynecological disease (16): clinical and ultrasound characteristics of serous cystadenofibromas in adnexa. Ultrasound Obstet Gynecol. 2019. PMID: 30937992. doi:10.1002/uog.20277

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。