文献速递腹部泌尿生殖CT

对已知无症状肾结石患者随访时限于肾脏的平扫CT的辐射剂量降低

Radiation Dose Reduction of Unenhanced CT Limited to the Kidneys for Follow-Up of Patients With Known Nephrolithiasis Without Symptoms.
PubMed 文献 · AJR Am J Roentgenol · 2019-04-11

本回顾性研究纳入2017年在本机构接受「腹部+盆腔肾结石」CT检查的299例成人患者,确定T11上终板至L5下终板为包含双肾的界标,该限制z轴范围使平均扫描长度减少50%,全身平均有效剂量降低41.5%,乳腺、性腺和膀胱剂量分别降低71.7%、73.8%和81.8%。

要点

  • T11上终板至L5下终板可几乎在所有扫描中包含双肾。
  • 限制z轴范围使平均扫描长度减少50%。
  • 全身平均有效剂量降低41.5%,乳腺、性腺和膀胱剂量分别降低71.7%、73.8%和81.8%。

核心结论

  • 对于无症状、接受CT监测以评估肾结石生长或新结石形成的患者,从T11上终板至L5下终板的限制范围扫描可显著降低辐射剂量。

研究设计与样本

  • 回顾性研究纳入2017年在本机构接受CT检查类型「腹部+盆腔肾结石」的所有成人患者,共299例符合纳入和排除标准;记录原CT扫描的辐射剂量和z轴长度,以及双肾相对于椎体终板的上、下界,以确定限于肾脏CT的z轴长度;使用市售辐射剂量分析软件包估算原CT扫描和限制范围CT扫描的全身和个别器官当量剂量。

诊断标准与关键数值

  • T11上终板和L5下终板是几乎在所有扫描中包含双肾的界标。
  • 限制z轴范围导致平均扫描长度减少50%。
  • 全身平均有效剂量降低41.5%。
  • 乳腺、性腺和膀胱器官剂量分别降低71.7%、73.8%和81.8%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of this study is to identify the landmarks and associated radiation dose reduction for limited CT of the kidneys of patients requiring follow-up for known nephrolithiasis. MATERIALS AND METHODS. This retrospective study included all adult patients who underwent CT examination type "CT abdomen + pelvis renal stone" at our institution during 2017. Several exclusion criteria were identified, including scoliosis and congenital renal abnormalities. A total of 299 patients met the inclusion and exclusion criteria. The radiation dose and z-axis length associated with the original CT scan were recorded. The upper and lower limits of both kidneys in relation to the vertebral body endplates were recorded, to determine the z-axis length for a CT scan limited to the kidneys. A commercially available radiation dose analytics software package was used to provide estimates of whole-body-and individual organ-equivalent doses for the original CT scan and the limited range CT scan. RESULTS. The superior endplate of T11 and the inferior endplate of L5 are landmarks that will include both kidneys on almost all scans. A limited z-axis range leads to a mean scan length reduction of 50%. The whole-body mean effective dose is reduced by 41.5%, and the doses to the breast and the gonadal and bladder organs are reduced by 71.7%, 73.8%, and 81.8%, respectively. CONCLUSION. For patients without symptoms who are undergoing CT surveillance to evaluate renal calculi growth, new stone formation, or both, a limited-range scan extending from the superior endplate of T11 to the inferior endplate of L5 results in a significant reduction in radiation dose.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Fananapazir G, Klimkiv L, Canvasser N, et al. Radiation Dose Reduction of Unenhanced CT Limited to the Kidneys for Follow-Up of Patients With Known Nephrolithiasis Without Symptoms. AJR Am J Roentgenol. 2019. PMID: 30973770. doi:10.2214/AJR.18.20805

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。