文献速递泌尿生殖MR

定量多参数磁共振成像方法对前列腺癌定位与侵袭性的单臂多中心验证研究

A Single-Arm, Multicenter Validation Study of Prostate Cancer Localization and Aggressiveness With a Quantitative Multiparametric Magnetic Resonance Imaging Approach.
PubMed 文献 · Invest Radiol · 2019-01-01

这项单臂多中心研究纳入5家机构50例经活检证实的前列腺癌患者,采用标准化术前mpMRI协议,评估定量mpMRI区分癌与非癌组织及不同肿瘤分级组的能力。结果显示扩散加权成像衍生的表观扩散系数区分效能最佳,外周带癌与非癌组织AUC为0.93,移行带为0.86,且各成像方法参数均与外周带肿瘤分级组显著相关。

要点

  • 扩散加权成像衍生的表观扩散系数是区分癌与非癌组织的最佳参数,外周带AUC 0.93、移行带AUC 0.86。
  • 表观扩散系数区分外周带GG1与更高分级组肿瘤的AUC为0.74。
  • 多参数联合逻辑回归模型区分外周带GG1-2与GG3-5肿瘤的AUC为0.89。

核心结论

  • 在3T标准化数据采集与后处理协议下,前列腺mpMRI定量结果在多机构患者间具有等效性,区分癌与非癌组织及肿瘤分级组的效能与既往单中心研究相似。

研究设计与样本

  • 单臂、多中心、单vendor验证研究,纳入5家机构50例经活检证实的前列腺癌患者,采用标准化术前mpMRI协议并以全mount组织病理切片为参考标准。

关键影像表现/征象

  • 定量参数在机构间变异较低,外周带和移行带占总方差比例均值分别为4%和8%,最大值分别为14%和46%。
  • 癌与非癌组织在外周带和移行带均以扩散加权成像衍生的表观扩散系数区分最佳,其次为MR波谱成像和动态对比增强衍生参数。

诊断标准与关键数值

  • 表观扩散系数区分外周带癌与非癌组织的AUC为0.93(95%CI 0.89-0.96),区分移行带癌与非癌组织的AUC为0.86(95%CI 0.75-0.94)。
  • 表观扩散系数区分外周带GG1与更高分级组肿瘤的AUC为0.74(95%CI 0.57-0.90),P<0.001。
  • 功能参数联合逻辑回归模型区分外周带GG1-2与GG3-5肿瘤的AUC为0.89(95%CI 0.78-0.98)。

临床应用与阅片要点

  • 在3T标准化协议下,表观扩散系数可作为区分前列腺癌与非癌组织的首选定量参数。
  • 多参数联合逻辑回归模型有助于区分外周带低级别与高级别肿瘤。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aims of this study were to assess the discriminative performance of quantitative multiparametric magnetic resonance imaging (mpMRI) between prostate cancer and noncancer tissues and between tumor grade groups (GGs) in a multicenter, single-vendor study, and to investigate to what extent site-specific differences affect variations in mpMRI parameters.

MATERIALS AND METHODS: Fifty patients with biopsy-proven prostate cancer from 5 institutions underwent a standardized preoperative mpMRI protocol. Based on the evaluation of whole-mount histopathology sections, regions of interest were placed on axial T2-weighed MRI scans in cancer and noncancer peripheral zone (PZ) and transition zone (TZ) tissue. Regions of interest were transferred to functional parameter maps, and quantitative parameters were extracted. Across-center variations in noncancer tissues, differences between tissues, and the relation to cancer grade groups were assessed using linear mixed-effects models and receiver operating characteristic analyses.

RESULTS: Variations in quantitative parameters were low across institutes (mean [maximum] proportion of total variance in PZ and TZ, 4% [14%] and 8% [46%], respectively). Cancer and noncancer tissues were best separated using the diffusion-weighted imaging-derived apparent diffusion coefficient, both in PZ and TZ (mean [95% confidence interval] areas under the receiver operating characteristic curve [AUCs]; 0.93 [0.89-0.96] and 0.86 [0.75-0.94]), followed by MR spectroscopic imaging and dynamic contrast-enhanced-derived parameters. Parameters from all imaging methods correlated significantly with tumor grade group in PZ tumors. In discriminating GG1 PZ tumors from higher GGs, the highest AUC was obtained with apparent diffusion coefficient (0.74 [0.57-0.90], P < 0.001). The best separation of GG1-2 from GG3-5 PZ tumors was with a logistic regression model of a combination of functional parameters (mean AUC, 0.89 [0.78-0.98]).

CONCLUSIONS: Standardized data acquisition and postprocessing protocols in prostate mpMRI at 3 T produce equivalent quantitative results across patients from multiple institutions and achieve similar discrimination between cancer and noncancer tissues and cancer grade groups as in previously reported single-center studies.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Maas MC, Litjens GJS, Wright AJ, et al. A Single-Arm, Multicenter Validation Study of Prostate Cancer Localization and Aggressiveness With a Quantitative Multiparametric Magnetic Resonance Imaging Approach. Invest Radiol. 2019. PMID: 30946180. doi:10.1097/RLI.0000000000000558

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。