文献速递泌尿生殖USMR

超声弹性成像Q分析评分联合前列腺影像报告和数据系统基于经直肠超声-磁共振融合成像对前列腺结节恶性风险分层的性能评估

Evaluation of the Performance of the Ultrasound (US) Elastographic Q-Analysis Score Combined With the Prostate Imaging Reporting and Data System for Malignancy Risk Stratification in Prostate Nodules Based on Transrectal US-Magnetic Resonance Imaging Fusion Imaging.
PubMed 文献 · J Ultrasound Med · 2019-04-01

本研究回顾性评估了超声弹性成像Q分析评分(EQS)联合前列腺影像报告和数据系统(PI-RADS)基于经直肠超声-磁共振融合成像对前列腺结节恶性风险分层的预后性能。62例疑似前列腺癌患者中29例为前列腺癌,EQS与PI-RADS均在恶性结节中显著更高,两者联合可在一定程度上提高诊断性能。

要点

  • EQS与PI-RADS在恶性结节中均显著高于良性结节。
  • EQS截断值2.05时敏感度86.2%、特异度81.8%、AUC 85.9%。
  • 串联法提高特异度至87.9%,并联法提高敏感度至96.5%。

核心结论

  • EQS与PI-RADS在鉴别前列腺良恶性病变方面均具有良好的诊断性能。
  • EQS与PI-RADS联合可在一定程度上提高诊断性能。

研究设计与样本

  • 回顾性评估2017年10月至2018年5月本院62例疑似前列腺癌患者的前列腺结节。
  • 基于经直肠超声-磁共振融合成像评估EQS与PI-RADS的性能。
  • 以患者受试者工作特征曲线评估鉴别良恶性前列腺结节的性能。
  • 所有患者均接受活检,29例为前列腺癌,其余为良性前列腺病变。

诊断标准与关键数值

  • EQS截断值2.05:敏感度86.2%、特异度81.8%、AUC 85.9%、阳性似然比4.73、阴性似然比0.169、阳性预测值80.6%、阴性预测值87.1%、约登指数68%。
  • PI-RADS截断值4:敏感度82.7%、特异度69.7%、AUC 84.2%、阳性似然比2.72、阴性似然比0.25、阳性预测值70.6%、阴性预测值82.1%、约登指数52.4%。
  • 串联法:诊断特异度87.9%、阳性似然比6.55、阳性预测值85.1%。
  • 并联法:诊断敏感度96.5%、阴性似然比0.06、阴性预测值95.2%。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study retrospectively evaluated the prognostic performance of the ultrasound elastographic Q-analysis score (EQS) combined with the Prostate Imaging Reporting and Data System (PI-RADS) for malignancy risk stratification in prostate nodules based on transrectal ultrasound-magnetic resonance imaging fusion imaging.

METHODS: Sixty-two patients who were suspected to have PCa between October 2017 and May 2018 in our hospital were retrospectively evaluated. The performance of the EQS and PI-RADS was evaluated by patients' receiver operating characteristic curves in differentiating malignant and benign prostate nodules. The combination of the EQS and PI-RADS methods for prostate imaging was evaluated.

RESULTS: Sixty-two prostate nodules in 62 patients were included. All of the patients underwent biopsy; 29 cases were prostate cancer, and the rest were benign prostate lesions. Both the EQS and PI-RADS were significantly higher in malignant nodules than in benign nodules. The sensitivity, specificity, area under the curve, positive likelihood ratio, negative likelihood ratio, positive predictive value, negative predictive value, and Youden index of an EQS cutoff of 2.05 were 86.2%, 81.8%, 85.9%, 4.73, 0.169, 80.6%, 87.1%, and 68%, respectively. The corresponding numbers for a PI-RADS cutoff of 4 were 82.7%, 69.7%, 84.2%, 2.72, 0.25, 70.6%, 82.1%, and 52.4%. The "tandem" method had a higher diagnostic specificity (87.9%), positive likelihood ratio (6.55), and positive predictive value (85.1%). The "parallel" method had a higher diagnostic sensitivity (96.5%), negative likelihood ratio (0.06), and negative predictive value (95.2%).

CONCLUSIONS: both the EQS and PI-RADS had good diagnostic performance in differentiating between malignant and benign prostate lesions. The combination of the EQS and PI-RADS improved the diagnostic performance to a certain degree.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Ding Z, Ye X, Zhang L, et al. Evaluation of the Performance of the Ultrasound (US) Elastographic Q-Analysis Score Combined With the Prostate Imaging Reporting and Data System for Malignancy Risk Stratification in Prostate Nodules Based on Transrectal US-Magnetic Resonance Imaging Fusion Imaging. J Ultrasound Med. 2019. PMID: 30937942. doi:10.1002/jum.15005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。