弥散加权成像单指数、双指数、拉伸指数与峰度模型在肾脏实性肿块鉴别中的比较
本研究纳入81例患者共81个肾脏实性病灶(良性18个、恶性63个),在3T MRI上比较单指数ADC、双指数、拉伸指数与峰度模型参数对良恶性及肾细胞癌亚型、分级的鉴别能力。拉伸指数模型的异常扩散系数α鉴别良恶性AUC最高(0.923),但各高级模型参数在鉴别RCC亚型或分级上均未显著优于ADC。
要点
- 拉伸指数模型拟合优度最高,良性病灶中90.7%、恶性病灶中51.4%的体素首选该模型。
- α鉴别肾脏良恶性肿块的AUC为0.923,为各参数中最高。
- ADC、Ds、MK在良恶性之间及低级别与高级别ccRCC之间均有显著差异(p<0.05)。
核心结论
- 与传统扩散参数相比,α可能为鉴别肾脏良恶性肿块提供额外信息,而ADC仍是鉴别RCC亚型和ccRCC分级最有价值的参数。
研究设计与样本
- 研究纳入81例患者(男56例、女25例;平均年龄57岁,年龄范围30-69岁),共18个良性病灶和63个恶性病灶,使用3T弥散加权MRI成像;采用Akaike信息准则评估每个病灶的扩散模型选择,统计分析使用Mann-Whitney U检验和受试者工作特征(ROC)分析。
诊断标准与关键数值
- 拟合优度分析显示拉伸指数模型在良性和恶性病灶中拥有最高体素百分比,分别为90.7%和51.4%。α鉴别良恶性病变的ROC曲线下面积最高,为0.923;ADC、Ds、MK在良恶性之间及低级别与高级别ccRCC之间差异显著(p<0.05);α在良性组显著低于恶性组(p<0.05);除Df(p=0.143)和α(p=0.112)外,所有扩散参数在ccRCC与非ccRCC之间均有显著差异(p<0.05)。
临床应用与阅片要点
- 在阅片与报告中可参考:拉伸指数模型的α对肾脏良恶性肿块鉴别具有较高诊断准确性(AUC 0.923),但鉴别RCC亚型及ccRCC分级时ADC仍为主要参数,高级模型参数未显示显著优势。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To compare various models of diffusion-weighted imaging including monoexponential apparent diffusion coefficient (ADC), biexponential (fast diffusion coefficient [Df], slow diffusion coefficient [Ds], and fraction of fast diffusion), stretched-exponential (distributed diffusion coefficient and anomalous exponent term [α]), and kurtosis (mean diffusivity and mean kurtosis [MK]) models in the differentiation of renal solid masses.
MATERIALS AND METHODS: A total of 81 patients (56 men and 25 women; mean age, 57 years; age range, 30-69 years) with 18 benign and 63 malignant lesions were imaged using 3T diffusion-weighted MRI. Diffusion model selection was investigated in each lesion using the Akaike information criteria. Mann-Whitney U test and receiver operating characteristic (ROC) analysis were used for statistical evaluations.
RESULTS: Goodness-of-fit analysis showed that the stretched-exponential model had the highest voxel percentages in benign and malignant lesions (90.7% and 51.4%, respectively). ADC, Ds, and MK showed significant differences between benign and malignant lesions (p < 0.05) and between low- and high-grade clear cell renal cell carcinoma (ccRCC) (p < 0.05). α was significantly lower in the benign group than in the malignant group (p < 0.05). All diffusion measures showed significant differences between ccRCC and non-ccRCC (p < 0.05) except Df and α (p = 0.143 and 0.112, respectively). α showed the highest diagnostic accuracy in differentiating benign and malignant lesions with an area under the ROC curve of 0.923, but none of the parameters from these advanced models revealed significantly better performance over ADC in discriminating subtypes or grades of renal cell carcinoma (RCC) (p > 0.05).
CONCLUSION: Compared with conventional diffusion parameters, α may provide additional information for differentiating benign and malignant renal masses, while ADC remains the most valuable parameter for differentiation of RCC subtypes and for ccRCC grading.
引用
- Zhang J, Suo S, Liu G, et al. Comparison of Monoexponential, Biexponential, Stretched-Exponential, and Kurtosis Models of Diffusion-Weighted Imaging in Differentiation of Renal Solid Masses. Korean J Radiol. 2019. PMID: 30993930. doi:10.3348/kjr.2018.0474
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。