文献速递泌尿生殖妇产影像MR

下尿路梗阻胎儿膀胱的磁共振成像生物测量与形态学特征:胎儿膀胱镜检查的新视角

Biometric and morphological features on magnetic resonance imaging of fetal bladder in lower urinary tract obstruction: new perspectives for fetal cystoscopy.
PubMed 文献 · Ultrasound Obstet Gynecol · 2020-01-01

本研究基于2015至2019年46例男性胎儿MRI(17例下尿路梗阻,29例年龄匹配对照),测量膀胱体积、壁厚及三个膀胱角度。下尿路梗阻组膀胱体积和壁厚显著更大(P<0.01),膀胱颈角显著更大(127.1° vs 111.2°,P<0.01),膀胱顶与后尿道角平均117°且组间无差异(P=0.92)。作者认为膀胱颈角在下尿路梗阻胎儿中增大约15°及膀胱顶与后尿道角平均117°有助于定制胎儿膀胱镜。

要点

  • 下尿路梗阻胎儿膀胱颈角较对照显著增大(127.1° vs 111.2°,P<0.01)。
  • 膀胱顶与后尿道角平均117°,下尿路梗阻与对照间无差异(P=0.92)。
  • 下尿路梗阻胎儿中仅膀胱颈角随孕周变化,25周后较25周及之前更大(P=0.04)。

核心结论

  • 下尿路梗阻胎儿膀胱颈角较对照增大约15°,膀胱顶与后尿道角平均117°,可能有助于开发定制胎儿膀胱镜并克服当前胎儿膀胱镜的技术挑战。

研究设计与样本

  • 解剖学研究,回顾性检索2015至2019年胎儿医学数据库,纳入46例男性胎儿MRI(17例下尿路梗阻,29例年龄匹配对照),下尿路梗阻组平均孕周28.1周(范围17.3-35.0),对照组29.9周(范围21.9-35.0)。

关键影像表现/征象

  • 下尿路梗阻组膀胱体积和膀胱壁厚度均显著大于对照组(P<0.01)。
  • 膀胱颈角在下尿路梗阻组显著大于对照组:均值(范围)127.1°(101.6-161.6°)vs 111.2°(88.5-157.3°)(P<0.01)。
  • 膀胱顶与后尿道角平均117°,组间无差异(P=0.92)。
  • 膀胱尿道角因多数对照胎儿无法测量而未进行统计学比较。
  • 方差分析显示下尿路梗阻胎儿和对照胎儿中任何角度均不随膀胱体积变化。

诊断标准与关键数值

  • 下尿路梗阻胎儿膀胱颈角均值(范围)127.1°(101.6-161.6°)vs 对照111.2°(88.5-157.3°)(P<0.01)。
  • 下尿路梗阻胎儿中膀胱颈角在25周后较25周及之前更大(P=0.04)。
  • 膀胱顶与后尿道角平均117°,组间无差异(P=0.92)。
  • 信度研究显示三个角度的观察者内和观察者间可重复性偏倚均可接受。

临床应用与阅片要点

  • 作者认为膀胱颈角在下尿路梗阻胎儿中增大约15°及膀胱顶与后尿道角平均117°可能有助于开发定制胎儿膀胱镜并克服当前胎儿膀胱镜的技术挑战。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Incompatibility between currently available fetoscopes and the anatomical constraints of the distended fetal bladder, with the resulting curvature around the bladder neck, account for most technical difficulties during fetal cystoscopy in lower urinary tract obstruction (LUTO). The aim of this anatomical study was to assess by magnetic resonance imaging (MRI) the variation in three bladder angles (bladder-neck angle (BNA), vesicourethral angle (VUA) and angle between bladder dome and posterior urethra (DUA)), according to gestational age (GA), bladder volume and the presence of LUTO.

METHODS: From our fetal medicine database, we retrieved for review 46 MRI examinations of male fetuses between 2015 and 2019, including 17 with LUTO, examined at a mean GA of 28.1 (range, 17.3-35.0) weeks and 29 age-matched controls, examined at 29.9 (range, 21.9-35.0) weeks. We measured bladder volume, bladder-wall thickness and the three bladder angles, and used the Mann-Whitney U-test to compare values between groups. Variations according to GA and bladder volume were determined using analysis of variance (ANOVA). A reliability study was performed using the Bland-Altman method and Lin's correlation coefficient was calculated.

RESULTS: Both bladder volume and bladder-wall thickness were significantly greater in the LUTO group (P < 0.01). BNA was significantly larger in LUTO compared with control fetuses: the mean (range) was 127.1° (101.6-161.6°) vs 111.2° (88.5-157.3°) (P < 0.01). DUA averaged 117° and showed no difference between the groups (P = 0.92). No statistical comparison was performed on VUA since this was not measurable in most control fetuses. ANOVA showed no variation of any angle with bladder volume in both LUTO fetuses and control fetuses. BNA in LUTO fetuses was the only angle to vary with GA, being larger after, compared with at or before, 25 weeks (P = 0.04). The reliability study showed an acceptable bias for both intra- and interobserver reproducibility for all three angles.

CONCLUSION: The findings that BNA is increased by approximately 15° in fetuses with LUTO and DUA averages 117° could aid in development of a customized fetal cystoscope and help to overcome the current technical challenges of fetal cystoscopy. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Vinit N, Grevent D, Millischer-Bellaiche AE, et al. Biometric and morphological features on magnetic resonance imaging of fetal bladder in lower urinary tract obstruction: new perspectives for fetal cystoscopy. Ultrasound Obstet Gynecol. 2020. PMID: 31006924. doi:10.1002/uog.20297

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。