双能CT碘图检测与表征肾移植患者非典型肾囊肿及实性肾肿块
回顾性纳入175例肾移植随访患者,行双能CT(单能平扫、延迟增强、皮质期增强双能期相)并重建虚拟平扫与物质分离图。以碘浓度>1500 μg/mL判定可疑强化病灶(强化>20 HU)的敏感度100%、特异度92.55%、阳性预测值50%、阴性预测值100%。双能CT碘图在检测与表征非典型囊性及实性肾病灶方面与常规增强CT表现相当,可能降低辐射剂量。
要点
- 碘浓度>1500 μg/mL判定强化>20 HU病灶:敏感度100%、特异度92.55%。
- 碘浓度>5000 μg/mL的2个病灶均为组织学证实的癌症。
- 碘图可替代常规增强图像检测肾移植患者非典型肾病灶。
核心结论
- 双能CT碘浓度图在检测与表征肾移植受者组织及非典型囊性肾病灶方面与常规CT增强图像表现相当。
- 使用该方法可能降低辐射剂量,尤其可通过避免平扫序列实现。
研究设计与样本
- 回顾性研究,纳入175例肾移植随访患者。
- 双能CT包括单能平扫、延迟增强及皮质期增强双能期相,重建虚拟平扫与物质分离图。
- 在病灶、膀胱及腰大肌上勾画ROI,采用物质抑制碘图记录平扫与虚拟平扫的衰减测量值,并在碘密度图上获取物质浓度测量值。
- 记录各序列的辐射剂量。
关键影像表现/征象
- 检出101个肾脏病灶(自发衰减>20 HU,大小>10 mm)。
诊断标准与关键数值
- 碘浓度阈值>1500 μg/mL检测可疑病灶(强化>20 HU)的敏感度100%、特异度92.55%、阳性预测值50%、阴性预测值100%。
- 碘浓度>5000 μg/mL的2个病灶对应仅有的2例组织学证实癌症。
临床应用与阅片要点
- 双能CT随访采用两个增强期相及重建物质图,在检测与表征非典型肾囊肿和肾肿块方面与三期常规CT诊断效能相同。
- 采用碘浓度图可能降低辐射剂量,尤其可通过避免平扫序列实现。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of this study was to evaluate whether dual-energy CT follow-up of kidney transplant recipients performed with only two contrast-enhanced phases and reconstructed material maps has the same diagnostic efficiency as triphasic conventional CT in detection and characterization of atypical renal cysts and renal masses. MATERIALS AND METHODS. In a retrospective study, 175 renal transplant patients underwent dual-energy CT as part of their follow-up (monoenergetic unenhanced, late contrast-enhanced, and tubular contrast-enhanced dual-energy phases). An unenhanced virtual series and material separation maps were reconstructed. ROIs were marked on theses lesions, the bladder, and the psoas muscle. Material suppressed iodine was used to record attenuation measurements on the unenhanced and virtual unenhanced series in the tubular and late phases, and material concentration measurements were obtained on the iodine density images. The delivered doses for each series were registered. RESULTS. One hundred one renal lesions (spontaneous attenuation > 20 HU, size > 10 mm) were detected. An iodine concentration threshold greater than 1500 μg/mL was associated with excellent diagnostic performance (sensitivity, 100%; specificity, 92.55%; positive predictive value, 50%; negative predictive value, 100%) for detection of suspect lesions (enhancement > 20 HU). The two lesions with an iodine concentration greater than 5000 μg/mL corresponded to the only two histologically proven cancers. CONCLUSION. Iodine concentration maps obtained with dual-energy CT perform as well as enhanced images obtained at conventional CT in the detection and characterization of tissue and atypical cystic renal lesions in kidney transplant recipients. Use of this method could reduce radiation dose, especially by avoiding the unenhanced series.
引用
- L'Hostis F, Vial J, Dallery F, et al. Detection and Characterization of Atypical Renal Cysts and Solid Renal Masses in Kidney Transplant Patients by Use of Dual-Energy CT Iodine Maps. AJR Am J Roentgenol. 2019. PMID: 30995100. doi:10.2214/AJR.18.20574
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。