文献速递泌尿生殖腹部MR

3-T多参数MRI采用PI-RADS分段法检测和定位前列腺癌

Detection and Localization of Prostate Cancer at 3-T Multiparametric MRI Using PI-RADS Segmentation.
PubMed 文献 · AJR Am J Roentgenol · 2019-04-17

研究对比415例连续男性患者的3-T多参数MRI与全mount病理,采用PI-RADSv2评分和分段法评估前列腺癌检测与定位效能。共863个癌灶、16185个前列腺分段。调整分段匹配模型较刚性模型定位敏感度更高(全病灶56.0% vs 28.5%),特异度两者均高(96.0-97.9%)。对≥1 cm且Gleason≥7的指数病灶检测敏感度最高(83.3%)。

要点

  • 调整分段匹配模型定位敏感度高于刚性模型(全病灶56.0% vs 28.5%)
  • 对≥1 cm且Gleason≥7的指数病灶检测敏感度达83.3%
  • 两种分段匹配模型特异度均高(96.0-97.9%)

核心结论

  • 采用3-T多参数MRI和PI-RADSv2,对≥1 cm且Gleason≥7的病灶检测敏感度最高(83.3%);前列腺内分段定位效能中等,调整模型优于刚性模型。

研究设计与样本

  • 研究纳入415例连续男性患者,对比3-T多参数MRI与薄层全mount病理;由泌尿生殖放射科医生和病理科医生共同判定一致性,两名放射科医生共识分配PI-RADSv2类别和分段位置;采用刚性和调整两种分段匹配模型。

诊断标准与关键数值

  • 多参数MRI检测≥1 cm病灶:全部病灶61.6% vs 指数病灶81.6%;检测Gleason≥7病灶:全部病灶71.4% vs 指数病灶80.9%;检测≥1 cm且Gleason≥7的指数病灶83.3%;调整模型 vs 刚性模型定位敏感度:全部病灶56.0% vs 28.5%,指数病灶55.4% vs 34.3%,Gleason≥7病灶55.7% vs 36.0%,≥1 cm指数病灶56.1% vs 35.0%;两种模型整体和指数肿瘤定位特异度96.0-97.9%。

临床应用与阅片要点

  • 阅片和报告时可参考本研究数据:PI-RADSv2分段法对≥1 cm且Gleason≥7的指数病灶检测敏感度最高,但整体分段定位敏感度中等,调整模型定位敏感度高于刚性模型。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of this study is to determine the overall and sector-based performance of 3-T multiparametric MRI for prostate cancer (PCa) detection and localization by using Prostate Imaging-Reporting and Data System version 2 (PI-RADSv2) scoring and segmentation compared with whole-mount histopathologic analysis. MATERIALS AND METHODS. Multiparametric 3-T MRI examinations of 415 consecutive men were compared with thin-section whole-mount histopathologic analysis. A genitourinary radiologist and pathologist collectively determined concordance. Two radiologists assigned PI-RADSv2 categories and sectoral location to all detected foci by consensus. Tumor detection rates were calculated for clinical and pathologic (Gleason score) variables. Both rigid and adjusted sector-matching models were used to account for fixation-related issues. RESULTS. The 415 patients had 863 PCa foci (52.7% had a Gleason score ≥ 7, 61.9% were ≥ 1 cm, and 90.4% (375/415) of index lesions were ≥ 1 cm) and 16,185 prostate sectors. Multiparametric MRI enabled greater detection of PCa lesions 1 cm or larger (all lesions vs index lesions, 61.6% vs 81.6%), lesions with Gleason score greater than or equal to 7 (all lesions vs index lesions, 71.4% vs 80.9%), and index lesions with both Gleason score greater than or equal to 7 and size 1 cm or larger (83.3%). Higher sensitivity was obtained for adjusted versus rigid tumor localization for all lesions (56.0% vs 28.5%), index lesions (55.4% vs 34.3%), lesions with Gleason score greater than or equal to 7 (55.7% vs 36.0%), and index lesions 1 cm or larger (56.1% vs 35.0%). Multiparametric 3-T MRI had similarly high specificity (96.0-97.9%) for overall and index tumor localization with adjusted and rigid sector-matching approaches. CONCLUSION. Using 3-T multiparametric MRI and PI-RADSv2, we achieved the highest sensitivity (83.3%) for the detection of lesions 1 cm or larger with Gleason score greater than or equal to 7. Sectoral localization of PCa within the prostate was moderate and was better with an adjusted model than with a rigid model.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Wibulpolprasert P, Raman SS, Hsu W, et al. Detection and Localization of Prostate Cancer at 3-T Multiparametric MRI Using PI-RADS Segmentation. AJR Am J Roentgenol. 2019. PMID: 30995090. doi:10.2214/AJR.18.20113

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。