文献速递腹部外周血管CT

在体型瘦小患者中采用80 kV与自适应统计迭代重建-V降低CT门静脉成像辐射剂量并提高图像质量

Reducing Radiation Dose and Improving Image Quality in CT Portal Venography Using 80 kV and Adaptive Statistical Iterative Reconstruction-V in Slender Patients.
PubMed 文献 · Acad Radiol · 2019-04-25

将60例体型瘦小患者随机分为两组,A组用120 kV、600 mgI/kg对比剂、40% ASIR,B组用80 kV、350 mgI/kg对比剂及40%–100% ASIR-V;B组有效剂量和对比剂剂量分别降低63.3%和39.7%,80%–100% ASIR-V可进一步改善图像质量,80% ASIR-V主观评分最高。

要点

  • 体型瘦小患者CTPV采用80 kV联合ASIR-V,有效剂量较120 kV/40% ASIR降低63.3%,对比剂剂量降低39.7%。
  • 80%–100% ASIR-V的SD值显著低于40% ASIR,70%–100% ASIR-V的SNR和CNR显著高于40% ASIR。
  • 60%–100% ASIR-V的主观评分及各评分项均显著高于40% ASIR,80% ASIR-V主观评分最高。

核心结论

  • 体型瘦小患者CTPV采用80 kV与ASIR-V重建可显著降低辐射剂量(63.3%)和对比剂剂量(39.7%),80%–100% ASIR-V较推荐40% ASIR进一步改善图像质量,以80% ASIR-V最佳。

研究设计与样本

  • 随机对照研究,60例体型瘦小行腹部增强CT扫描患者随机分为A组和B组;A组用120 kV、600 mgI/kg对比剂、40% ASIR重建,B组用80 kV、350 mgI/kg对比剂、40%–100% ASIR-V(间隔10%)重建;两名有经验放射科医师盲法采用5分标准主观评分。

关键影像表现/征象

  • B组较A组有效剂量降低63.3%(p < 0.001),对比剂剂量降低39.7%(p < 0.001)。
  • B组随ASIR-V比例增加,CT值无显著差异,SD值逐渐降低,SNR值和CNR值相应升高。
  • B组CT值与A组无显著差异(p > 0.05)。
  • 80%–100% ASIR-V的SD值显著低于40% ASIR(p < 0.001),70%–100% ASIR-V的SNR值和CNR值显著高于40% ASIR(p < 0.001)。
  • 两名医师主观评分一致性极好(kappa值>0.75,p < 0.001),60%–100% ASIR-V的最终主观评分及5个评分项均显著高于40% ASIR,80% ASIR-V主观评分最高。

诊断标准与关键数值

  • 主观图像质量采用5分标准由两名有经验放射科医师盲法评分。
  • B组ASIR-V重建比例范围为40%至100%,间隔10%。

临床应用与阅片要点

  • 体型瘦小患者CTPV可考虑采用80 kV联合ASIR-V重建以降低辐射和对比剂剂量。
  • 重建比例可考虑选择80% ASIR-V,因其主观评分最高且SD、SNR、CNR表现优于40% ASIR。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To explore the feasibility of reducing radiation dose and improving image quality in CT portal venography (CTPV) using 80 kV and adaptive statistical iterative reconstruction-V(ASIR-V) in slender patients in comparison with conventional protocol using 120 kV and ASIR.

METHODS: Sixty slender patients for enhanced abdominal CT scanning were randomly divided into group A and group B. Group A used the conventional 120 kV tube voltage, 600 mgI/kg contrast dose and reconstructed with the recommended 40% ASIR. Group B used 80 kV tube voltage, 350 mgI/kg contrast dose and reconstructed with ASIR-V from 40% to 100% with 10% interval. The CT values and standard deviation (SD) values of the main portal vein, left branch, and right branch of portal vein, liver, and erector spinae at the same level were measured to calculate the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). The image quality was subjectively scored by two experienced radiologists blindly using a 5-point criterion. The contrast dose, volumetric CT dose index, and dose length product were recorded in both groups and the effective dose was calculated.

RESULTS: There was no significant difference in general data between the two groups (p > 0.05), the effective dose and contrast dose in group B were reduced by 63.3% (p < 0.001) and 39.7% (p < 0.001), respectively compared with group A. With the percentage of ASIR-V increased in group B, the CT values showed no significant difference, while the SD values gradually decreased and SNR values and CNR values increased accordingly. Compared with group A, group B demonstrated similar CT values (p > 0.05), while the SD values with 80% ASIR-V to 100% ASIR-V were significantly lower than those of 40% ASIR (p < 0.001), and the SNR values and CNR values with 70% ASIR-V to 100% ASIR-V were significantly higher than those of 40% ASIR (p < 0.001). The subjective image quality scores by the two radiologists had excellent consistency (kappa value>0.75, p < 0.001), and the final subjective image quality scores and the subjective scores in each of the 5 scoring categories with 60% ASIR-V to 100% ASIR-V were all significantly higher than those of 40% ASIR, and 80% ASIR-V obtained the highest subjective score among different reconstructions.

CONCLUSION: In CTPV, the application of 80 kV and ASIR-V reconstruction in slender patients can significantly reduce radiation dose (by 63.3%) and contrast agent dose (by 39.7%). Compared with the recommended 40% ASIR using 120 kV, ASIR-V with 80% to 100% percentages can further improve image quality and with 80% ASIR-V being the best reconstruction algorithm.

ADVANCES IN KNOWLEDGE: CTPV with 80 kV and ASIR-V algorithm in slender patients can significantly reduce radiation dose and contrast agent dose as well as improve image quality, compared with the conventional 120 kV protocol using 40% ASIR.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Ren Z, Zhang X, Hu Z, et al. Reducing Radiation Dose and Improving Image Quality in CT Portal Venography Using 80 kV and Adaptive Statistical Iterative Reconstruction-V in Slender Patients. Acad Radiol. 2019. PMID: 31031186. doi:10.1016/j.acra.2019.02.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。