PubMed 文献 · Abdom Radiol (NY) · 2019-01-01

本回顾性研究纳入554例在2014至2018年间至少接受2次钆塞酸增强MRI(1.5或3.0 Tesla)的患者,测量T1加权图像上注射前及约20分钟后肝信号强度,计算肝脏相对强化、肝脾信号比和肝肌信号比。连续两次检查间上述指标无统计学显著差异,患者年龄与肝脏相对强化、肝脾信号比及肝肌信号比均呈负相关。

要点

  • 连续两次钆塞酸增强MRI的肝脏相对强化、肝脾信号比和肝肌信号比无统计学显著差异。
  • 患者年龄与肝脏相对强化(p=0.002)、肝脾信号比(p<0.001)和肝肌信号比(p=0.006)呈负相关。
  • 不同扫描仪类型和场强下肝脏相对强化在连续检查中保持一致。

核心结论

  • 钆塞酸增强MRI肝胆期肝脏相对强化在连续检查、不同扫描仪类型和场强下保持一致,并与年龄呈负相关,进一步支持其作为基于影像的肝功能检查的有效性。

研究设计与样本

  • 回顾性研究纳入554例在2014至2018年间于本机构接受至少2次钆塞酸增强MRI(1.5或3.0 Tesla)的患者。

诊断标准与关键数值

  • 肝脏相对强化、肝脾信号比和肝肌信号比在连续两次MRI检查间无统计学显著差异(配对t检验或Greenhouse-Geisser检验,样本量分别为554、519和554)。
  • Greenhouse-Geisser检验显示第1次与第4次MRI扫描间有统计学显著差异,但线性混合模型未证实该差异。
  • 患者年龄与肝脏相对强化呈负相关(p=0.002),与肝脾信号比呈负相关(p<0.001),与肝肌信号比呈负相关(p=0.006)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the consistency of liver enhancement in gadoxetic acid-enhanced magnetic resonance imaging (MRI) over serial examinations.

METHODS: This retrospective study included 554 patients who underwent at least 2 serial gadoxetic acid-enhanced MRI scans at either 1.5 or 3.0 Tesla at our institution between 2014 and 2018. Signal intensities (SI) were measured on T1-weighted images before and approx. 20 min after intravenous injection of gadoxetic acid. Relative enhancement (RE) of the liver, liver-to-spleen SI ratio (LSR), and liver-to-muscle SI ratio (LMR) were calculated. Means were compared with the paired t test, Greenhouse-Geisser test, and linear mixed model analysis, accordingly. Multiple linear regression analysis was used to elucidate possible predictors of RE and bivariate correlation analysis of patient age with RE was performed.

RESULTS: No statistically significant difference in RE, LSR, and LMR between two consecutive MRI scans was found when tested with paired t test or Greenhouse-Geisser test (n = 554, 519, and 554, respectively), while the latter revealed a statistically significant difference between the first and fourth MRI scan which was not confirmed in the linear mixed model. Patient age correlated negatively with RE of the liver (p = 0.002), LSR (p < 0.001), and LMR (p = 0.006).

CONCLUSIONS: Relative enhancement of the liver in the hepatobiliary phase of gadoxetic acid-enhanced MRI is consistent over successive examinations, different scanner types, and field strengths while correlating negatively with age, which further underscores the validity of gadoxetic acid-enhanced MRI as an imaging-based liver function test.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。