二维剪切波弹性成像鉴别3岁以下儿童肝母细胞瘤与肝血管瘤的诊断效能
前瞻性纳入109例经病理或增强CT加随访观察确诊的肝脏肿瘤患儿,其中71例为试验组、38例为验证组,评估二维剪切波弹性成像鉴别肝母细胞瘤与肝血管瘤的效能。肝母细胞瘤平均弹性值58.4±19.5 kPa,血管瘤19.0±16.0 kPa;试验组最佳截断值39.5 kPa,AUC 0.915,敏感度88.1%、特异度86.2%,验证组准确率86.8%。作者认为二维剪切波弹性成像可作为辅助方法帮助鉴别两者。
要点
- 肝母细胞瘤弹性值58.4±19.5 kPa,肝血管瘤19.0±16.0 kPa(Z=-7.685,p=0.000)。
- 试验组截断值39.5 kPa,AUC 0.915,敏感度88.1%、特异度86.2%。
- 验证组该阈值准确率86.8%,观察者间与观察者内ICC分别为0.946和0.971。
核心结论
- 二维剪切波弹性成像作为辅助方法可能有助于鉴别儿童肝母细胞瘤与肝血管瘤。
研究设计与样本
- 前瞻性研究,连续纳入109例经病理分析或增强CT加随访观察确诊的肝脏肿瘤患儿,试验组71例、验证组38例,采用二维剪切波弹性成像测量病灶弹性值,以ROC分析确定试验组最佳截断值并在验证组分析其准确率。
关键影像表现/征象
- 肝母细胞瘤平均弹性值为58.4±19.5 kPa。
- 肝血管瘤平均弹性值为19.0±16.0 kPa。
- 肝血管瘤患者中弹性值与病灶大小呈正相关(r=0.332,p=0.023),肝母细胞瘤患者中无显著相关性(r=0.222,p=0.082)。
- 肝血管瘤(r=0.205,p=0.167)与肝母细胞瘤(r=0.047,p=0.715)中弹性值与年龄均无显著相关性。
诊断标准与关键数值
- 试验组鉴别肝母细胞瘤与肝血管瘤的最佳截断值为39.5 kPa,AUC 0.915,敏感度88.1%、特异度86.2%。
- 验证组中该阈值准确率为86.8%。
- 弹性测量观察者间ICC为0.946,观察者内ICC为0.971。
临床应用与阅片要点
- 作者认为二维剪切波弹性成像作为辅助方法可能有助于鉴别肝母细胞瘤与肝血管瘤。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The aim of the present study was to prospectively evaluate the clinical efficiency of 2-D shear wave elastography (2-D-SWE) for differentiating hepatoblastoma and hepatic hemangioma in children under 3 y of age. 2-D-SWE was performed in 109 consecutive patients with confirmed hepatic neoplasms by pathologic analysis or contrast-enhanced computed tomography plus follow-up observation, in which 71 patients were defined as the test group, and the remaining 38 patients were defined as the validation group. An elasticity value was obtained from each lesion. The diagnostic performance and optimal cut-off value were determined by receiver operating characteristic (ROC) analysis in the test group, and the accuracy of this threshold was analyzed in the validation group. The interclass correlation coefficient (ICC) and Spearman rank correlation tests were applied to assess the reproducibility of elastic measurement and the relationship between the elasticity value and potential influencing parameters. The mean elasticity values were 58.4 ± 19.5 kPa for hepatoblastoma and 19.0 ± 16.0 kPa for hemangioma (Z = -7.685, p = 0.000). The cut-off value in the test group was 39.5 kPa with an area under the ROC curve for differentiation of 0.915, sensitivity of 88.1% and specificity of 86.2%. The accuracy of this threshold in the validation group was 86.8%. The ICCs for inter- and intra-observer reproducibility for acquisition of the elastic measurement were 0.946 and 0.971, respectively. No significant correlation was found between the elasticity value and age for either hemangioma (r = 0.205, p = 0.167) or hepatoblastoma (r = 0.047, p = 0.715). The elasticity value was positively correlated with lesion size (r = 0.332, p = 0.023) in patients with hemangioma but not in patients with hepatoblastoma (r = 0.222, p = 0.082). As a complementary method, 2-D-SWE may aid the differentiation of hepatoblastoma and hemangioma.
引用
- Wang Y, Jia L, Wang X, et al. Diagnostic Performance of 2-D Shear Wave Elastography for Differentiation of Hepatoblastoma and Hepatic Hemangioma in Children under 3 Years of Age. Ultrasound Med Biol. 2019. PMID: 30979592. doi:10.1016/j.ultrasmedbio.2019.02.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。