自由呼吸三维径向磁共振成像技术定量婴儿体成分与肝脏脂肪
研究纳入10名2-7月龄婴儿,比较自由呼吸三维堆叠径向MRI与笛卡尔MRI的肝脏图像质量,并评估径向MRI定量体成分和肝脏质子密度脂肪分数的可行性。径向MRI肝脏图像质量评分显著高于笛卡尔MRI(P=0.01),可重复性系数<2.0%,提示该技术可行。
要点
- 自由呼吸径向MRI肝脏图像质量评分中位数2和3,显著高于笛卡尔MRI的1(P=0.01)。
- 径向MRI测得婴儿肝脏PDFF中位数3.4%,重复性系数<2.0%。
- 径向MRI可定量内脏、皮下和棕色脂肪组织体积及PDFF。
核心结论
- 自由呼吸径向MRI在婴儿肝脏图像质量上显著优于笛卡尔MRI,且能可行地定量体成分和肝脏脂肪。
研究设计与样本
- 前瞻性可行性研究,10名2-7月龄婴儿完成自由呼吸径向(腹部2次,头胸部1次)和笛卡尔(腹部1次)MRI扫描,9名完成全部研究(完成率90%)。
关键影像表现/征象
- 自由呼吸径向MRI肝脏图像质量评分中位数:第1次扫描2分,第2次扫描3分;笛卡尔MRI中位数1分(P=0.01)。
- 径向MRI测量中位数:内脏脂肪体积52.0 cm3,内脏脂肪PDFF 42.2%,皮下脂肪体积267.7 cm3,皮下脂肪PDFF 87.1%,棕色脂肪体积1.4 cm3,棕色脂肪PDFF 26.1%,肝脏PDFF 3.4%。
诊断标准与关键数值
- 图像质量采用3分法评估运动伪影:1分为不可诊断,3分为无伪影。
- 肝脏PDFF重复性系数<2.0%。
临床应用与阅片要点
- 自由呼吸径向MRI可用于婴儿腹部成像,减少呼吸运动伪影,提高肝脏图像质量。
- 可定量婴儿内脏、皮下和棕色脂肪组织体积及PDFF,以及肝脏PDFF。
局限性
- 本研究样本量小,共10名婴儿,仅9名完成全部研究。
- 原文未报告其他局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Body composition and hepatic fat correlate with future risk for metabolic syndrome. In children, many conventional techniques for quantifying body composition and hepatic fat have limitations. MRI is a noninvasive research tool to study body composition and hepatic fat in infants; however, conventional Cartesian MRI is sensitive to motion, particularly in the abdomen because of respiration. Therefore we developed a free-breathing MRI technique to quantify body composition and hepatic fat in infants.
OBJECTIVE: In infants, we aimed to (1) compare the image quality between free-breathing 3-D stack-of-radial MRI (free-breathing radial) and 3-D Cartesian MRI in the liver and (2) determine the feasibility of using free-breathing radial MRI to quantify body composition and hepatic proton-density fat fraction (PDFF).
MATERIALS AND METHODS: Ten infants ages 2-7 months were scanned with free-breathing radial (two abdominal; one head and chest) and Cartesian (one abdominal) MRI sequences. The median preparation and scan times were reported. To assess feasibility for hepatic PDFF quantification, a radiologist masked to the MRI technique scored abdominal scans for motion artifacts in the liver using a 3-point scale (1, or non-diagnostic, to 3, or no artifacts). Median visceral adipose tissue (VAT), subcutaneous adipose tissue (SAT) and brown adipose tissue (BAT) volume and PDFF, and hepatic PDFF were measured using free-breathing radial MRI. We assessed repeatability of free-breathing radial hepatic PDFF (coefficient of repeatability) between back-to-back scans. We determined differences in the distribution of image-quality scores using McNemar-Bowker tests. P<0.05 was considered significant.
RESULTS: Nine infants completed the entire study (90% completion). For ten infants, the median preparation time was 32 min and scan time was 24 min. Free-breathing radial MRI demonstrated significantly higher image-quality scores compared to Cartesian MRI in the liver (radial scan 1 median = 2 and radial scan 2 median = 3 vs. Cartesian median = 1; P=0.01). Median measurements using free-breathing radial were VAT=52.0 cm3, VAT-PDFF=42.2%, SAT=267.7 cm3, SAT-PDFF=87.1%, BAT=1.4 cm3, BAT-PDFF=26.1% and hepatic PDFF=3.4% (coefficient of repeatability <2.0%).
CONCLUSION: In this study, free-breathing radial MRI in infants achieved significantly improved liver image quality compared to Cartesian MRI. It is feasible to use free-breathing radial MRI to quantify body composition and hepatic fat in infants.
引用
- Armstrong T, Ly KV, Ghahremani S, et al. Free-breathing 3-D quantification of infant body composition and hepatic fat using a stack-of-radial magnetic resonance imaging technique. Pediatr Radiol. 2019. PMID: 31001664. doi:10.1007/s00247-019-04384-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。