二维超声剪切波弹性成像在大型儿童及年轻成人队列中的技术成功率:一项临床有效性研究
该回顾性研究纳入2016年2月至2018年3月573例儿童及年轻成人肝脏二维超声剪切波弹性成像检查,以10次剪切波速度测量的四分位距/中位数评估技术成功率,三种方法判定技术不合格率分别为5.1%、4.9%和5.2%,约95%检查技术成功。
要点
- 儿童及年轻成人肝脏二维超声剪切波弹性成像约95%检查技术成功。
- 以四分位距/中位数>0.3判定,573例中29例(5.1%)技术不合格。
- 年龄、腹壁厚度、中位剪切波速度和探头是测量变异性的预测因素。
核心结论
- 基于四分位距/中位数评估,儿童及年轻成人肝脏二维超声剪切波弹性成像约95%检查技术成功。
研究设计与样本
- 回顾性识别2016年2月至2018年3月间进行的临床肝脏二维超声剪切波弹性成像检查,共573例,记录年龄、性别、10次剪切波速度测量的中位数/均值、四分位距/中位数、腹壁厚度、体重指数、血清丙氨酸氨基转移酶及所用探头。
诊断标准与关键数值
- 方法1以四分位距/中位数>0.3判定技术不合格,29/573例(5.1%)不合格;方法2以四分位距/中位数>本研究人群第95百分位(截止值=0.303)判定,28/573例(4.9%)不合格;方法3以Tukey法识别统计离群值判定,30/573例(5.2%)不合格。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: There is a paucity of available literature describing the frequency of technical success of liver two-dimensional (2-D) ultrasound (US) shear wave elastography (SWE) in children and young adults.
OBJECTIVE: To determine the frequency of technical success of liver 2-D ultrasound (US) SWE in children and young adults based on the interquartile range (IQR)/median of 10 shear wave speed (SWS) measurements.
MATERIALS AND METHODS: Clinical 2-D US SWE exams performed between February 2016 and March 2018 were retrospectively identified. Patient age and gender, median/mean liver stiffness (10 SWS measurements), IQR/median, abdominal wall thickness, body mass index (BMI) and serum alanine aminotransferase (ALT) were documented. The number of technically inadequate exams was calculated using three methods: 1) IQR/median >0.3, 2) IQR/median >95th percentile for our study population and 3) statistical outlier identification using the Tukey method. The effect of age, gender, median SWS, abdominal wall thickness, BMI, US transducer and ALT on measurement variability (IQR/median) was assessed using multivariable linear regression.
RESULTS: During the study period, 573 exams were performed. Mean age was 12.6±7.1 years; 274 (47.8%) exams were in male patients. Average median liver stiffness was 1.75±0.47 m/s. Based on Methods 1, 2 and 3, 29/573 (5.1%), 28/573 (4.9%, IQR/median cutoff value=0.303) and 30/573 (5.2%) exams were technically inadequate. Predictors of IQR/median included age (P=0.03), abdominal wall thickness (P=0.003), median SWS (P<0.0001) and transducer (P<0.0001).
CONCLUSION: Approximately 95% of liver 2-D US SWE exams are technically successful based on IQR/median in children and young adults.
引用
- Northern NA, Dillman JR, Trout AT, et al. Frequency of technical success of two-dimensional ultrasound shear wave elastography in a large pediatric and young adult cohort: a clinical effectiveness study. Pediatr Radiol. 2019. PMID: 30949727. doi:10.1007/s00247-019-04396-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。