文献速递腹部技术与安全CT

双能CT定量参数术前诊断结直肠癌区域淋巴结转移

Preoperative Diagnosis of Regional Lymph Node Metastasis of Colorectal Cancer With Quantitative Parameters From Dual-Energy CT.
PubMed 文献 · AJR Am J Roentgenol · 2019-04-17

本研究对178例结肠或高位直肠癌患者行三期增强双能CT,测量最大区域淋巴结的形态学标准、短轴径及定量参数,并与病理对照。动脉期归一化碘浓度联合门静脉期归一化有效原子序数诊断准确率最高达87.1%(AUC 0.916),优于形态学标准和短轴径。

要点

  • 门静脉期归一化有效原子序数鉴别转移与非转移淋巴结AUC 0.871、准确率84.8%。
  • 动脉期归一化碘浓度联合门静脉期归一化有效原子序数准确率87.1%、AUC 0.916。
  • 双能CT定量参数诊断准确率高于形态学标准(准确率47.8-62.4%)和短轴径(66.3%)。

核心结论

  • 双能CT定量参数可提高结直肠癌区域转移淋巴结的术前诊断准确率。

研究设计与样本

  • 对178例结肠或高位直肠癌患者行三期增强双能CT,测量最大区域淋巴结的形态学标准、短轴径和定量参数,以病理为参考标准,采用单因素和多因素logistic回归分析及ROC曲线分析。

诊断标准与关键数值

  • 门静脉期归一化有效原子序数诊断转移淋巴结的AUC为0.871、准确率为84.8%。
  • 形态学标准诊断转移淋巴结的AUC为0.505-0.624、准确率为47.8-62.4%。
  • 短轴径诊断转移淋巴结的AUC为0.647、准确率为66.3%。
  • 动脉期归一化碘浓度联合门静脉期归一化有效原子序数诊断准确率为87.1%、AUC为0.916。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of this study was to investigate the performance of quantitative parameters derived from dual-energy CT (DECT) in the preoperative diagnosis of regional metastatic lymph nodes (LNs) in patients with colorectal cancer. SUBJECTS AND METHODS. Triphasic contrast-enhanced DECT was performed for 178 patients with colon or high rectal cancer. The morphologic criteria, short-axis diameter, and quantitative DECT parameters of the largest regional LN were measured and compared between pathologically metastatic and nonmetastatic LNs. Univariate and multivariable logistic regression analyses were used to determine the independent DECT parameters for predicting LN metastasis. Diagnostic performance measures were assessed by ROC curve analysis and compared by McNemar test. RESULTS. A total of 178 largest LNs (72 metastatic, 106 nonmetastatic) were identified in 178 patients. The best single DECT parameter for differentiation between metastatic and nonmetastatic LNs was normalized effective atomic number (Zeff) in the portal venous phase (AUC, 0.871; accuracy, 84.8%). These values were higher than those of morphologic criteria (AUC, 0.505-0.624; accuracy, 47.8-62.4%) and short-axis diameter (AUC, 0.647; accuracy, 66.3%) (p < 0.05). The diagnostic accuracy of combined normalized iodine concentration in the arterial phase and normalized effective atomic number in the portal venous phase was further improved to 87.1% (AUC, 0.916). CONCLUSION. Quantitative parameters derived from DECT can be used to improve preoperative diagnostic accuracy in evaluation for regional metastatic LNs in patients with colorectal cancer.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Yang Z, Zhang X, Fang M, et al. Preoperative Diagnosis of Regional Lymph Node Metastasis of Colorectal Cancer With Quantitative Parameters From Dual-Energy CT. AJR Am J Roentgenol. 2019. PMID: 30995087. doi:10.2214/AJR.18.20843

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。