简化IVIM扩散加权成像在3.0 T下进行肝脏病灶定性是否同样可行?
研究评估简化体素内不相干运动(IVIM)扩散加权成像在3.0 T下定性肝脏病灶的效能,并与1.5 T比较。3.0 T分析116个病灶(78例患者)及27个健康肝脏,1.5 T分析173个病灶(110例患者)及40个健康肝脏。局灶性结节性增生以f1'鉴别最佳(AUC 0.993),血管瘤以D1'鉴别最佳(AUC 1.000),恶性与良性病灶鉴别以ADC最佳(AUC 0.968),D1'联合f1'正确识别率99.1%优于ADC的88.8%;3.0 T鉴别恶性与良性病灶的效能较1.5 T有更高趋势。
要点
- 3.0 T简化IVIM可用于肝脏病灶定性,仅需b=0、50、800 s/mm²三个b值。
- 血管瘤以D1'鉴别最佳(AUC 1.000),局灶性结节性增生以f1'鉴别最佳(AUC 0.993)。
- 恶性与良性病灶鉴别以ADC最佳(AUC 0.968),D1'联合f1'正确识别率99.1%优于ADC的88.8%。
核心结论
- 简化IVIM适用于3.0 T肝脏病灶定性,鉴别恶性与良性病灶的诊断准确性较1.5 T有更高趋势。
研究设计与样本
- 3.0 T呼吸门控MRI序列b=0、50、250、800 s/mm²,分析116个病灶(78例患者)及27个健康肝脏,并与1.5 T的173个病灶(110例患者)及40个健康肝脏比较。
关键影像表现/征象
- 计算ADC(0,800)、D1'=ADC(50,800)、D2'=ADC(250,800)、f1'=f(0,50,800)、f2'=f(0,250,800)、D*'=D*(0,50,250,800)、ADClow=ADC(0,50)及ADCdiff=ADClow-D2',按患者分析。
诊断标准与关键数值
- 局灶性结节性增生与所有其他病灶鉴别以f1'最佳,AUC为0.993。
- 血管瘤与其他病灶鉴别以D1'最佳,AUC为1.000。
- 恶性与良性病灶鉴别以ADC最佳,AUC为0.968。
- D1'联合f1'正确识别恶性或良性病灶的比例为99.1%,高于ADC的88.8%。
- 3.0 T鉴别恶性与良性病灶的效能较1.5 T有更高趋势。
临床应用与阅片要点
- 3.0 T肝脏病灶定性可采用简化IVIM方案,仅需采集b=0、50、800 s/mm²三个b值。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate simplified intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) for liver lesion characterisation at 3.0 T and to compare it with 1.5 T.
METHODS: 3.0-T DWI data from a respiratory-gated MRI sequence with b = 0, 50, 250, and 800 s/mm2 were analysed in 116 lesions (78 patients) and 27 healthy livers. Apparent diffusion coefficient ADC = ADC(0,800) and IVIM-based parameters D1' = ADC(50,800), D2' = ADC(250,800), f1' = f(0,50,800), f2' = f(0,250,800), D*' = D*(0,50,250,800), ADClow = ADC(0,50), and ADCdiff = ADClow-D2' were calculated voxel-wise and analysed on per-patient basis. Results were compared with those of 173 lesions (110 patients) and 40 healthy livers at 1.5 T.
RESULTS: Focal nodular hyperplasias were best discriminated from all other lesions by f1' and haemangiomas by D1' with an area under the curve (AUC) of 0.993 and 1.000, respectively. For discrimination between malignant and benign lesions, ADC was best suited (AUC of 0.968). The combination of D1' and f1' correctly identified more lesions as malignant or benign than the ADC (99.1% vs 88.8%). Discriminatory power for differentiating malignant from benign lesions tended to be higher at 3.0 T than at 1.5 T.
CONCLUSION: Simplified IVIM is suitable for lesion characterisation at 3.0 T with a trend of superior diagnostic accuracy for discriminating malignant from benign lesions compared with 1.5 T.
KEY POINTS: • Simplified IVIM is also suitable for liver lesion characterisation at 3.0 T. • Excellent accuracy was reached for discriminating malignant from benign lesions. • The acquisition of only three b-values (0, 50, 800 s/mm 2 ) is required.
引用
- Mürtz P, Pieper CC, Reick M, et al. Is liver lesion characterisation by simplified IVIM DWI also feasible at 3.0 T? Eur Radiol. 2019. PMID: 30963269. doi:10.1007/s00330-019-06192-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。