文献速递腹部技术与安全USMR

超声评估肝脏脂肪与MRI对照的准确性

Accuracy of ultrasonography in the assessment of liver fat compared with MRI.
PubMed 文献 · Clin Radiol · 2019-04-05

研究以1.5 T磁共振化学位移编码成像为参考标准,评估B型超声在2783名志愿者中检测肝脂肪变性的准确性,并探讨肝铁过载的影响。结果显示超声敏感度74.5%、特异度86.6%,敏感度随脂肪含量增加而升高,检测准确性不受肝铁含量影响。

要点

  • 超声检测肝脂肪变性总体敏感度74.5%、特异度86.6%,低脂肪含量时敏感度仅65.1%。
  • 超声敏感度随肝脂肪含量增加而升高,中、高脂肪含量时分别为95%和96%。
  • 肝铁含量不影响超声检测肝脂肪变性的诊断准确性。

核心结论

  • 超声是临床评估肝脂肪变性的优良工具,但在低肝脏脂肪含量患者中存在一定局限,且其检测不受肝铁影响。

研究设计与样本

  • 共纳入2783名志愿者(女性1442名、男性1341名,平均年龄52.3±13.8岁),均行1.5 T肝脏化学位移编码MRI计算质子密度脂肪分数和横向弛豫率,并以B型超声评估肝脂肪变性。

诊断标准与关键数值

  • 以MRI为参考标准,超声检测肝脂肪变性的总体敏感度为74.5%、特异度为86.6%;低、中、高脂肪含量时敏感度分别为65.1%、95%、96%,特异度恒定为86.6%。

临床应用与阅片要点

  • 阅片时需注意超声对低肝脏脂肪含量者敏感度较低(65.1%),报告脂肪肝阴性时不能完全排除轻度脂肪变性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To investigate the accuracy of ultrasonography in the assessment of hepatic steatosis using magnetic resonance imaging (MRI) as standard of reference and to explore the influence of additional hepatic iron overload.

MATERIAL AND METHODS: A total of 2,783 volunteers (1,442 women, 1,341 men; mean age, 52.3±13.8 years) underwent confounder-corrected chemical-shift-encoded MRI of the liver at 1.5 T. Proton-density fat fraction (PDFF) and transverse relaxation rate (R2*) were calculated to estimate hepatic steatosis and liver iron overload, respectively. In addition, the presence of hepatic steatosis was assessed by B-mode ultrasonography. The sensitivity, specificity, and accuracy of hepatic ultrasonography were determined for different degrees of hepatic steatosis and different amounts of liver iron.

RESULTS: MRI revealed hepatic steatosis in 40% of participants (n=1,112), which was mild in 68.9% (n=766), moderate in 26.7% (n=297), and severe in 4.4% (n=49) of patients. Ultrasonography detected hepatic steatosis in 37.8% (n=1,052), corresponding to 74.5% sensitivity and 86.6% specificity. The sensitivity of ultrasound increased with the amount of hepatic fat present and was 65.1%, 95%, and 96% for low, moderate, and high fat content; whereas the specificity was constantly high at 86.6%. The diagnostic accuracy of ultrasound for detection of hepatic steatosis did not vary significantly with the amount of liver iron present.

CONCLUSION: Ultrasonography is an excellent tool to assess hepatic steatosis in the clinical setting with some limitations in patients with a low liver fat content. The detection of hepatic steatosis by ultrasonography is not influenced by liver iron.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Kromrey ML, Ittermann T, Berning M, et al. Accuracy of ultrasonography in the assessment of liver fat compared with MRI. Clin Radiol. 2019. PMID: 30955836. doi:10.1016/j.crad.2019.02.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。