双能量光谱CT定量参数鉴别肝脓肿与肝转移瘤
研究纳入51例患者共73个肝脏病灶(28个肝脓肿、45个肝转移瘤),行平扫及增强光谱CT,测量平扫囊性成分的CT值、斜率K、有效原子序数及脂肪/血浓度,以及增强三期病灶壁的标准化碘浓度(NIC)。平扫40 keV CT值鉴别两者的AUC为0.761,联合延迟期NIC后AUC提升至0.963。
要点
- 平扫40 keV CT值鉴别肝脓肿与肝转移瘤的AUC为0.761,敏感度71.4%、特异度75.6%。
- 联合延迟期NIC后AUC提升至0.963,敏感度89.3%、特异度93.3%。
- 平扫CT值、斜率K、Eff-Z、脂肪及血浓度在肝脓肿与肝转移瘤间均有显著差异(均P<0.05)。
核心结论
- 单源双能量CT定量参数在鉴别肝脓肿与肝转移瘤方面提供较高的诊断准确率。
研究设计与样本
- 研究纳入51例患者共73个肝脏病灶,其中肝脓肿28个、肝转移瘤45个,均行平扫及增强光谱CT扫描。
- 以病理或临床诊断为参考标准未在原文中明确描述。
诊断标准与关键数值
- 平扫40 keV CT值鉴别肝脓肿与肝转移瘤的AUC为0.761,敏感度71.4%、特异度75.6%。
- 平扫40 keV CT值联合延迟期NIC后AUC为0.963,敏感度89.3%、特异度93.3%。
- 平扫期CT值、斜率K、Eff-Z、脂肪浓度及血浓度在肝脓肿与肝转移瘤间差异有统计学意义(均P<0.05)。
- 增强静脉期及延迟期NIC在肝脓肿与肝转移瘤间差异有统计学意义(均P<0.05)。
临床应用与阅片要点
- 作者认为单源双能量CT定量参数在鉴别肝脓肿与肝转移瘤方面提供较高的诊断准确率。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To explore the value of single source dual-energy spectral CT quantitative parameters in differential diagnosis of liver abscess and liver metastatic tumor.
METHODS: Fifty-one patients with 73 liver lesions (28 liver abscesses and 45 liver metastases) underwent plain and contrast-enhanced spectral CT scans. The fat and blood concentrations and CT values of 40-140 keV monochromatic images were measured to calculate effective atomic number (Eff-Z) and a slope (K): [CT(40 keV)-CT(140 keV)/100] for the cystic component on the plain scan images. The iodine concentration of the lesion wall on the enhanced three-phase images were measured and normalized to that of aorta for normalized iodine concentration (NIC). All of the single quantitative parameters were compared between liver abscesses and liver metastases by the independent samples t-test or Mann-Whitney U test. Statistical difference parameters between liver abscesses and liver metastases were analyzed by receiver-operating characteristic (ROC) curves. The diagnostic capability was determined by calculating the area under the curve (AUC). Using binary logistics regression analysis combining the best diagnostic performance parameter in the plain and enhanced phase images. The predictive model of liver abscess was established, and the receiver operating characteristic (ROC) analysis was performed.
RESULTS: There were significant differences in CT value, the slope (K), Eff-Z, blood and fat concentrations in the plain phase and NIC in the contrast-enhanced venous and delay phases between liver abscesses and liver metastases (all P < 0.05). The CT value at 40 keV in the plain phase provided 0.761 in area under the curve (AUC) in ROC with sensitivity of 71.4% and, specificity of 75.6% in differentiating liver abscess and tumor. Combining with NIC in delay phase, the respectively values improved to 0.963, and 89.3% and 93.3%.
CONCLUSION: The quantitative parameters in single source dual-energy CT provide high diagnostic accuracy in differentiating liver abscesses from liver metastases.
引用
- Wang N, Ju Y, Wu J, et al. Differentiation of liver abscess from liver metastasis using dual-energy spectral CT quantitative parameters. Eur J Radiol. 2019. PMID: 30927948. doi:10.1016/j.ejrad.2019.02.024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。