点剪切波弹性成像新增可靠性测量指数:通过诊断性能与可重复性进行前瞻性验证
前瞻性纳入49例肝手术前患者,同时行提供可靠性测量指数(RMI)的点剪切波弹性成像(pSWE)与瞬时弹性成像(TE)。以10次连续测量中位值为参考,按RMI阈值0.0、0.4、0.7分层,分别最少需7、5、3次测量即可达到组内相关系数≥0.95且观察者间一致性≥0.90,诊断性能无显著差异,RMI有助于提高可靠性并减少测量次数。
要点
- RMI≥0.0时最少7次、RMI≥0.4时最少5次、RMI≥0.7时最少3次pSWE测量即可达到ICC≥0.95。
- 采用上述减少的测量次数后,诊断性能与参考标准相比无显著差异(P>0.05)。
- 减少测量次数后的肝硬度值与TE及METAVIR分期均呈显著相关(P<0.001)。
核心结论
- RMI有助于提高点剪切波弹性成像的可靠性并减少肝硬度测量次数,同时维持其诊断性能。
研究设计与样本
- 前瞻性研究,纳入49例拟行肝脏手术的患者,术前均接受提供RMI(范围0.0-1.0)的pSWE和瞬时弹性成像(TE)检查;以10次连续测量中位值(LS-REF)为参考,按RMI≥0.0、≥0.4、≥0.7分层比较前2至9次测量中位值与LS-REF的组内相关系数(ICC)。
诊断标准与关键数值
- 与LS-REF相比,获得ICC≥0.95且观察者间一致性ICC≥0.90所需的最少测量次数为:RMI≥0.0时7次、RMI≥0.4时5次、RMI≥0.7时3次;采用这些减少的测量次数后诊断性能无显著差异(P>0.05);减少测量次数后的肝硬度值与TE及METAVIR分期显著相关(P<0.001)。
临床应用与阅片要点
- 在点剪切波弹性成像肝硬度测量中可参考RMI值调整测量次数:RMI≥0.0时至少7次、RMI≥0.4时至少5次、RMI≥0.7时至少3次,以在维持诊断性能的同时提高检查效率。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The clinical value of the reliability measurement index (RMI), newly added to point shear wave elastography (pSWE), was investigated. Forty-nine patients underwent both pSWE providing RMI (range: 0.0-1.0) and transient elastography (TE) before hepatic surgery. Interclass correlation coefficients (ICCs) between the median of the first two to nine measurements (as categorized by RMI values ≥0.0 (liver stiffness-reliability measurement index [LS-RMI] 0.0), ≥0.4 (LS-RMI 0.4) and ≥0.7 (LS-RMI 0.7) and the median of 10 consecutive measurements (LS-REF) were obtained. Compared with LS-REF, minimums of 7 LS-RMI 0.0, 5 LS-RMI 0.4 and 3 LS-RMI 0.7 measurements were required to obtain an ICC ≥0.95 with high inter-observer agreement (ICC ≥0.90). Diagnostic performance did not differ (p values >0.05) using these reduced numbers of LS measurements. Significant correlations were found between the reduced number of LS measurements and TE or METAVIR (p values <0.001). Therefore, RMI helped to improve reliability and reduce the number of LS measurements while maintaining the diagnostic performance of pSWE.
引用
- Kang HJ, Lee JY, Lee KB, et al. Addition of Reliability Measurement Index to Point Shear Wave Elastography: Prospective Validation via Diagnostic Performance and Reproducibility. Ultrasound Med Biol. 2019. PMID: 31031036. doi:10.1016/j.ultrasmedbio.2019.03.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。