文献速递腹部CT

慢性胰腺炎CT报告标准的观察者间一致性研究

Interobserver agreement of computed tomography reporting standards for chronic pancreatitis.
PubMed 文献 · Abdom Radiol (NY) · 2019-01-01

回顾性分析47例慢性胰腺炎患者的胰腺方案CT,由两名放射科医生按慢性胰腺炎CT报告标准独立评估,总体观察者间一致性极好(84.8%,K=0.80,95%CI 0.75-0.85,P=0.001),提示该报告标准是诊断慢性胰腺炎的可靠方法。

要点

  • 慢性胰腺炎CT报告标准总体观察者间一致性极好(84.8%,K=0.80)。
  • 胰管结石、胰腺钙化及胰腺直径的观察者间一致性极好(K分别为0.84、0.86、0.87)。
  • 胰管狭窄的观察者间一致性原文报告为K=0.070(95%CI 0.53-0.88)。

核心结论

  • 慢性胰腺炎CT报告标准是诊断慢性胰腺炎患者的可靠方法。

研究设计与样本

  • 回顾性分析47例慢性胰腺炎患者的CT资料,其中男性33例、女性11例,年龄范围36至56岁。
  • 临床表现包括腹痛(n=41)、脂肪泻(n=37)和葡萄糖不耐受(n=31)。
  • 采用16排多探测器CT扫描仪行胰腺方案检查:平扫后静脉注射非离子型对比剂,分别在35秒行动脉期(原文写作「pancreatic phase」)和65秒行门静脉期扫描。
  • 由两名放射科医生按慢性胰腺炎报告标准进行图像分析。

诊断标准与关键数值

  • 总体报告标准观察者间一致性84.8%,K=0.80(95%CI 0.75-0.85,P=0.001)。
  • 胰管直径K=0.71(95%CI 0.56-0.87,P=0.001),胰管轮廓K=0.76(95%CI 0.61-0.91,P=0.001)。
  • 病变分布K=0.69(95%CI 0.51-0.86,P=0.001)。
  • 胰管内结石K=0.84(95%CI 0.68-0.98,P=0.001),胰腺钙化K=0.86(95%CI 0.84-0.98,P=0.001),胰腺直径K=0.87(95%CI 0.75-0.99,P=0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To assess the interobserver agreement of computed tomography (CT) reporting standards for chronic pancreatitis (CP).

SUBJECTS AND METHODS: Retrospective analysis of CT of 47 patients (33 males and 11 females, age range 36 to 56 years) with CP who presented with abdominal pain (n = 41), steatorrhea (n = 37), and glucose intolerance (n = 31). The patients underwent CT study using a 16-multidetector CT scanner with a pancreatic protocol including a nonenhanced scan followed by pancreatic phase at 35 s and portal venous phase at 65 s after intravenous injection of nonionic contrast medium. Image analysis was performed by two radiologists according to reporting standards for CP.

RESULTS: There was excellent interobserver agreement (84.8 %) between the two reviewers in CT reporting standards for CP (K = 0.80, 95 % CI 0.75-0.85, P = 0.001). There was good interobserver agreement for pancreatic duct (PD) caliber (K = 0.71, 95 % CI 0.56-0.87, P = 0.001), PD contour (K = 0.76, 95 % CI 0.61-0.91, P = 0.001), PD stricture (K = 0.070, 95 % CI 0.53-0.88, P = 0.001), and distribution of findings (K = 0.69, 95 % CI 0.51-0.86, P = 0.001). There was excellent interobserver agreement for intraductal calculi (K = 0.84, 95 % CI 0.68-0.98, P = 0.001), pancreatic calcifications (K = 0.86, 95 % CI 0.84-0.98, P = 0.001), and pancreatic diameter (K = 0.87, 95 % CI 0.75-0.99, P = 0.001).

CONCLUSION: CT reporting standards for CP is a reliable method for diagnosis of patients with CP.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Razek AAKA, Elfar E, Abubacker S, et al. Interobserver agreement of computed tomography reporting standards for chronic pancreatitis. Abdom Radiol (NY). 2019. PMID: 30955070. doi:10.1007/s00261-019-01979-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。