文献速递心血管CT

碘浓度和碘输送率对冠状动脉CT血管造影对比增强的影响:一项随机多中心试验(CT-CON)

Impact of iodine concentration and iodine delivery rate on contrast enhancement in coronary CT angiography: a randomized multicenter trial (CT-CON).
PubMed 文献 · Eur Radiol · 2019-04-23

结果显示各组冠状动脉内衰减值相似(平均384–395 HU,p=0.079),心率变化无差异(p=0.974),但注射压力峰值随对比剂黏度不同而显著不同(p<0.0001)。结论认为在相同碘输送率下,血管内衰减和心率变化与碘浓度无关。

要点

  • 相同碘输送率(2.0 g I/s)下,冠状动脉CTA对比增强程度与碘浓度无关。
  • 碘浓度不影响注射对比剂后的心率变化。
  • 注射压力峰值差异与对比剂黏度相关,而非碘浓度本身。

核心结论

  • 在相同碘输送率下,血管内衰减和心率变化与碘浓度无关;注射压力差异与对比剂黏度相关。

诊断标准与关键数值

  • 冠状动脉内衰减值:300 mg I/ml组未报告均值,350 mg I/ml组平均384 HU,370 mg I/ml组未报告均值,400 mg I/ml组平均395 HU(总体p=0.079);注射压力峰值:300 mg I/ml组197.4 psi(黏度4.6 mPa·s),350 mg I/ml组229.8 psi(10.4 mPa·s),370 mg I/ml组216.1 psi(9.5 mPa·s),400 mg I/ml组243.7 psi(12.6 mPa·s)(p<0.0001)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the effect of contrast medium iodine concentration on contrast enhancement, heart rate, and injection pressure when injected at a constant iodine delivery rate in coronary CT angiography (CTA).

METHODS: One thousand twenty-four patients scheduled for coronary CTA were prospectively randomized to receive one of four contrast media: iopromide 300 mg I/ml, iohexol 350 mg I/ml, iopromide 370 mg I/ml, or iomeprol 400 mg I/ml. Contrast media were delivered at an equivalent iodine delivery rate of 2.0 g I/s. Intracoronary attenuation was measured and compared (per vessel and per segment). Heart rate before and after contrast media injection was documented. Injection pressure was recorded (n = 403) during contrast medium injection and compared between groups.

RESULTS: Intracoronary attenuation values were similar for the different contrast groups. The mean attenuation over all segments ranged between 384 HU for 350 mg I/ml and 395 HU for 400 mg I/ml (p = 0.079). Dose-length product (p = 0.8424), signal-to-noise ratio (all p > 0.05), time to peak (p = 0.324), and changes in heart rate (p = 0.974) were comparable between groups. The peak pressures differed: 197.4 psi for 300 mg I/ml (viscosity 4.6 mPa s), 229.8 psi for 350 mg I/ml (10.4 mPa s), 216.1 psi for 370 mg I/ml (9.5 mPa s), and 243.7 psi for 400 mg I/ml (12.6 mPa s) (p < 0.0001).

CONCLUSION: Intravascular attenuation and changes in heart rate are independent of iodine concentration when contrast media are injected at the same iodine delivery rate. Differences in injection pressures are associated with the viscosity of the contrast media.

KEY POINTS: • The contrast enhancement in coronary CT angiography is independent of the iodine concentration when contrast media are injected at body temperature (37 °C) with the same iodine delivery rate. • Iodine concentration does not influence the change in heart rate when contrast media are injected at identical iodine delivery rates. • For a fixed iodine delivery rate and contrast temperature, the viscosity of the contrast medium affects the injection pressure.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Rengo M, Dharampal A, Lubbers M, et al. Impact of iodine concentration and iodine delivery rate on contrast enhancement in coronary CT angiography: a randomized multicenter trial (CT-CON). Eur Radiol. 2019. PMID: 31016447. doi:10.1007/s00330-019-06196-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。