心脏CT扫描中对比剂碘剂量影响辐射诱导的DNA损伤水平
研究用迷你猪模型接受固定心脏CT扫描方案12次,比较未增强、50%盐水稀释碘对比剂(160 mg I/mL)和标准碘克沙醇(320 mg I/mL)三种方案,发现γ-H2AX焦点数较未增强方案分别增加56.1%和141.1%,且较低碘剂量对应较低DNA损伤水平。
要点
- 心脏CT中使用碘对比剂可显著增加血液淋巴细胞辐射诱导的DNA双链断裂。
- 在相同辐射暴露下,较低碘剂量(160 mg I/mL)的DNA损伤程度低于标准碘剂量(320 mg I/mL)。
- 数值剂量学模型模拟结果与体内实验结果一致。
核心结论
- 心脏CT检查中给予对比剂显著增加血液淋巴细胞辐射诱导的DNA损伤,且在恒定辐射暴露下较低对比剂碘剂量导致DNA损伤水平降低。
研究设计与样本
- 动物实验研究,迷你猪总共接受12次固定心脏CT扫描方案,比较未增强方案与两种对比剂注射方案(50%盐水稀释至160 mg I/mL和标准碘克沙醇320 mg I/mL),采用γ-H2AX免疫荧光染色评估血液淋巴细胞辐射诱导的DNA双链断裂,并使用数值剂量学模型模拟心脏CT扫描(心脏以含0、10、20、30、40、50 mg I/mL六种碘浓度混合的血容量表示)。
诊断标准与关键数值
- 与未增强方案(0 mg I/mL)相比,每细胞γ-H2AX焦点数在降低碘剂量方案(160 mg I/mL)增加56.1%、在标准碘剂量方案(320 mg I/mL)增加141.1%,差异显著(p < 0.038);剂量学模拟模型显示左心室局部吸收血液剂量在降低碘剂量方案增加78.8%、标准碘剂量方案增加133.7%。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of this study is to investigate the contributing effect of contrast media (CM) iodine dose on radiation-induced DNA damage in blood lymphocytes during a cardiac CT scan. MATERIALS AND METHODS. The minipigs were exposed 12 times in total to a fixed cardiac CT scan protocol. An unenhanced and two CM injection protocols were considered, the latter with 50% saline diluted (160 mg I/mL) and standard iodixanol. Blood samples were collected before and after CT, and radiation-induced DNA double-strand breaks were assessed using γ-H2AX (H2A histone family member X) immunofluorescent staining of the blood lymphocytes. Significant differences in foci numbers were investigated with an independent sample t test. In addition, a numeric dosimetry model was applied that simulates the cardiac CT scan, with the heart represented by a blood volume containing a mixture of six iodine concentrations (0, 10, 20, 30, 40, and 50 mg I/mL). RESULTS. Compared with the unenhanced (0 mg I/mL) protocol, the number of γ-H2AX foci per cell increased significantly (p < 0.038), by 56.1% for the reduced iodine dose (160 mg I/mL) and by 141.1% for the standard iodine dose (320 mg I/mL) protocols. These in vivo results are confirmed by the dosimetry simulation model, in which 78.8% and 133.7% increases in locally absorbed blood dose in the left ventricle were observed for the reduced and standard iodine dose protocols, respectively. CONCLUSION. Administration of CM during a cardiac CT examination significantly increases radiation-induced DNA damage in blood lymphocytes. Moreover, a lower CM iodine dose results in a reduced level of DNA damage, at constant radiation exposure.
引用
- Van Cauteren T, Honoria Da Silva E, Van Gompel G, et al. Iodine Dose of Administered Contrast Media Affects the Level of Radiation-Induced DNA Damage During Cardiac CT Scans. AJR Am J Roentgenol. 2019. PMID: 31012759. doi:10.2214/AJR.18.20950
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。