文献速递心血管CT

血管扩张剂负荷CT心肌灌注成像中运动校正改善冠状动脉可视化

Improved visualization of the coronary arteries using motion correction during vasodilator stress CT myocardial perfusion imaging.
PubMed 文献 · Eur J Radiol · 2019-03-02

研究纳入28例临床指征行冠状动脉CT血管成像的患者,在瑞加德松负荷后行CT灌注成像,比较标准滤波反投影与运动补偿重建对冠状动脉显示的效果。运动补偿重建提高了所有冠状动脉节段的运动伪影评分,包括16%在标准重建判为不可诊断的节段,且信噪比和对比噪声比无显著变化。作者认为该算法是单次扫描联合评估冠状动脉解剖与心肌灌注的重要一步,可减少检查时间、辐射和对比剂剂量。

要点

  • 运动补偿重建提高所有冠状动脉节段的运动伪影评分,包括标准重建判为不可诊断的节段。
  • 运动校正后信噪比7±2 vs 标准7±3(p=0.88)、对比噪声比15±8 vs 标准15±5(p=0.94),均无显著变化。
  • 运动伪影评分采用0-5分,3分为诊断质量阈值。

核心结论

  • 运动补偿重建改善负荷CT灌注图像上冠状动脉解剖的显示,且不降低图像特性。
  • 作者认为该算法是实现单次扫描联合评估冠状动脉解剖与心肌灌注的重要一步,可减少检查时间、辐射暴露和对比剂剂量。

研究设计与样本

  • 研究纳入28例临床指征行冠状动脉CT血管成像的患者,使用iCT(Philips)设备。
  • 负荷CT灌注成像采用回顾性门控加剂量调制,参数为100 kVp和250 mA,辐射剂量5.2±4.3 mSv。
  • 负荷药物为瑞加德松0.4 mg(Astellas)。
  • 负荷图像分别用标准滤波反投影和运动补偿反投影重建,由对重建技术设盲的读片者逐节段评估运动伪影严重程度(0-5分,3分为诊断质量阈值),并测量信噪比和对比噪声比。

关键影像表现/征象

  • 运动补偿重建下所有冠状动脉节段的运动伪影可视化评分均高于标准滤波反投影。
  • 86个节段中有14个(16%)在标准滤波反投影图像上被判为不可诊断。

诊断标准与关键数值

  • 运动伪影严重程度按节段评分,采用0-5分,3分为诊断质量阈值。
  • 信噪比:运动校正后7±2 vs 标准滤波反投影7±3(p=0.88),无显著变化。
  • 对比噪声比:运动校正后15±8 vs 标准滤波反投影15±5(p=0.94),无显著变化。

临床应用与阅片要点

  • 对负荷CT灌注图像应用运动补偿重建可改善冠状动脉解剖显示,包括标准重建判为不可诊断的节段。
  • 运动校正未显著改变信噪比和对比噪声比,图像特性未见降低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Vasodilator stress computed tomography perfusion (sCTP) imaging is complementary to coronary CT angiography (CCTA), used to determine the hemodynamic significance of coronary artery disease. However, it requires a separate image acquisition due to motion artifacts caused by higher heart rates during stress, resulting in increased iodine contrast dose and radiation. We sought to determine whether a novel motion correction algorithm applied to stress images would improve the visualization of the coronary arteries to potentially allow CCTA + sCTP evaluation in a single scan.

METHODS: 28 patients referred for clinically indicated CCTA (iCT, Philips) underwent sCTP imaging (retrospective-gating with dose modulation; 100 kVp and 250 mA; 5.2 ± 4.3 mSv) after regadenoson (0.4 mg, Astellas). Stress images were reconstructed using standard filtered back-projection (FBP) and also processed to generate interaction-free coronary motion-compensated back-projection reconstructions (MCR). Each coronary artery from standard FBP and MCR images was viewed side-by-side by a reader blinded to the reconstruction technique, who graded severity of motion artifact by segment (scale 0-5, with 3 as the threshold for diagnostic quality) and to measure signal-to-noise and contrast-to-noise ratios (SNR, CNR).

RESULTS: Visualization scores were higher with MCR for all coronary segments, including 14/86 (16%) segments deemed as non-diagnostic on FBP images. SNR (7 ± 2) and CNR (15 ± 8) were unchanged by motion-correction (7 ± 3, p = 0.88 and 15 ± 5, p = 0.94, respectively).

CONCLUSIONS: MCR improves the visualization of coronary anatomy on sCTP images without degrading image characteristics. This algorithm is an important step towards the combined assessment of coronary anatomy and myocardial perfusion in a single scan, which will reduce study time, radiation exposure and contrast dose.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Balaney B, Vembar M, Grass M, et al. Improved visualization of the coronary arteries using motion correction during vasodilator stress CT myocardial perfusion imaging. Eur J Radiol. 2019. PMID: 31005158. doi:10.1016/j.ejrad.2019.02.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。