全心脏覆盖扫描仪动态负荷CT灌注联合冠状动脉CT血管成像及CT衍生血流储备分数的诊断价值
本研究前瞻性纳入85例拟行有创冠状动脉造影的症状性患者,评估在全心脏覆盖CT上行动态负荷心肌CT灌注联合冠状动脉CT血管成像及CT衍生血流储备分数诊断功能性显著冠心病的准确性。结果显示,cCTA+FFRCT+CTP序贯策略的AUC最高(0.919),优于其他策略;动态CTP平均有效辐射剂量为5.3±0.7 mSv。
要点
- cCTA+FFRCT+CTP序贯策略诊断功能性显著冠心病的AUC最高(0.919),优于cCTA单用及其他联合策略。
- 单独加做FFRCT或CTP均可提高AUC(分别为0.876和0.878),优于cCTA单用(0.826)。
- 动态负荷CTP平均有效辐射剂量为5.3±0.7 mSv,cCTA为2.8±1.2 mSv。
核心结论
- 在cCTA和FFRCT基础上加做动态负荷CTP可提供额外诊断准确性,且辐射暴露可接受。
研究设计与样本
- 前瞻性研究,连续纳入85例拟行有创冠状动脉造影的症状性患者,所有患者均行静息cCTA后使用全心脏覆盖CT扫描仪(Revolution CT,GE Healthcare)行动态负荷CTP,并基于静息cCTA数据集测量FFRCT;以有创冠状动脉造影和有创FFR为参考标准,在血管水平评估诊断准确性。
诊断标准与关键数值
- 以有创冠状动脉造影和有创FFR为参考标准,血管水平检测功能性显著冠心病的敏感度和特异度:cCTA单用为83%和66%,cCTA+FFRCT为86%和75%,cCTA+CTP为73%和86%;AUC分别为cCTA单用0.826、cCTA+FFRCT 0.876、cCTA+CTP 0.878,cCTA+FFRCT+CTP序贯策略AUC最高(0.919),与所有其他策略相比p<0.05。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aims of the study were to test the diagnostic accuracy of integrated evaluation of dynamic myocardial computed tomography perfusion (CTP) on top of coronary computed tomography angiography (cCTA) plus fractional flow reserve computed tomography derived (FFRCT) by using a whole-heart coverage computed tomography (CT) scanner as compared with clinically indicated invasive coronary angiography (ICA) and invasive fractional flow reserve (FFR).
BACKGROUND: Recently, new techniques such as dynamic stress computed tomography perfusion (stress-CTP) emerged as potential strategies to combine anatomical and functional evaluation in a one-shot scan. However, previous experiences with this technique were associated with high radiation exposure.
METHODS: Eighty-five consecutive symptomatic patients scheduled for ICA were prospectively enrolled. All patients underwent rest cCTA followed by stress dynamic CTP with a whole-heart coverage CT scanner (Revolution CT, GE Healthcare, Milwaukee, Wisconsin). FFRCT was also measured by using the rest cCTA dataset. The diagnostic accuracy to detect functionally significant coronary artery disease (CAD) in a vessel-based model of cCTA alone, cCTA+FFRCT, cCTA+CTP, or cCTA+FFRCT+CTP were assessed and compared by using ICA and invasive FFR as reference. The overall effective dose of dynamic CTP was also measured.
RESULTS: The prevalence of obstructive CAD and functionally significant CAD was 77% and 57%, respectively. The sensitivity and specificity of cCTA alone, cCTA+FFRCT, and cCTA+CTP were 83% and 66%, 86% and 75%, and 73% and 86%, respectively. Both the addition of FFRCT and CTP improves the area under the curve (AUC: 0.876 and 0.878, respectively) as compared with cCTA alone (0.826; p < 0.05). The sequential strategy of cCTA+FFRCT+CTP showed the highest AUC (0.919; p < 0.05) as compared with all other strategies. The mean effective radiation dose (ED) for cCTA and stress CTP was 2.8 ± 1.2 mSv and 5.3 ± 0.7 mSv, respectively.
CONCLUSIONS: The addition of dynamic stress CTP on top of cCTA and FFRCT provides additional diagnostic accuracy with acceptable radiation exposure.
引用
- Pontone G, Baggiano A, Andreini D, et al. Dynamic Stress Computed Tomography Perfusion With a Whole-Heart Coverage Scanner in Addition to Coronary Computed Tomography Angiography and Fractional Flow Reserve Computed Tomography Derived. JACC Cardiovasc Imaging. 2019. PMID: 31005531. doi:10.1016/j.jcmg.2019.02.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。