低剂量动态CT心肌灌注成像量化的心肌血流量与ST段抬高型心肌梗死患者峰值肌钙蛋白水平及左心室功能受损相关
本研究连续纳入35例ST段抬高型心肌梗死(STEMI)患者,均在梗死后1周内成功接受再灌注治疗,行动态CT心肌灌注成像(CT-MPI),分析26例患者427个心肌节段的定量参数与高敏肌钙蛋白T(hs-TnT)峰值及左心室射血分数(LVEF)的相关性。结果显示梗死区域心肌血流量(MBF)和心肌血容量(MBV)显著低于参考区域,MBF与峰值hs-TnT呈最佳负相关(r=-0.682),且仅MBF与入院时及6个月时LVEF显著相关。
要点
- 梗死区域MBF(30.5±7.4 mL/min/100 mL)显著低于参考区域(73.4±8.1 mL/min/100 mL),p<0.001。
- MBF与峰值hs-TnT呈最佳负相关(r=-0.682,p<0.001),MBV呈中度负相关(r=-0.437,p=0.026)。
- 仅MBF与入院时LVEF(r=0.469,p=0.016)及6个月时LVEF(r=0.585,p=0.001)显著相关。
核心结论
- 动态CT-MPI量化的MBF与峰值hs-TnT水平呈显著负相关,且MBF较低的患者在入院时及6个月时倾向于存在左心室功能受损。
研究设计与样本
- 连续纳入35例STEMI患者,均在梗死后1周内成功接受再灌注治疗,所有患者行动态CT-MPI;记录系列hs-TnT水平和超声心动图测量的LVEF;最终26例患者共427个心肌节段纳入分析。
关键影像表现/征象
- 梗死区域MBF为30.5±7.4 mL/min/100 mL,显著低于参考区域的73.4±8.1 mL/min/100 mL(p<0.001)。
- 梗死区域MBV为2.8±0.9 mL/100 mL,显著低于参考区域的4.2±1.1 mL/100 mL(p=0.044)。
诊断标准与关键数值
- MBF与峰值hs-TnT水平呈最佳负相关(r=-0.682,p<0.001)。
- MBV与峰值hs-TnT水平呈中度负相关(r=-0.437,p=0.026)。
- 其他动态CT-MPI定量参数与hs-TnT水平无显著相关性。
- 仅MBF与入院时LVEF显著相关(r=0.469,p=0.016),与6个月时LVEF显著相关(r=0.585,p=0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate the association of myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) with troponin level and left ventricle (LV) function in patients with ST-segment elevated myocardial infarction (STEMI).
MATERIALS AND METHODS: Thirty-five STEMI patients who successfully had undergone reperfusion treatment within 1 week of their infarction were consecutively enrolled. All patients were referred for dynamic CT-MPI. Serial high-sensitivity troponin T (hs-TnT) levels and left ventricular ejection fraction (LVEF) measured by echocardiography were recorded. Twenty-six patients with 427 segments were included for analysis. Various quantitative parameters derived from dynamic CT-MPI were analyzed to determine if there was a correlation between hs-TnT levels and LVEF on admission and again at the 6-month mark.
RESULTS: The mean radiation dose for dynamic CT-MPI was 3.2 ± 1.1 mSv. Infarcted territories had significantly lower MBF (30.5 ± 7.4 mL/min/100 mL versus 73.4 ± 8.1 mL/min/100 mL, p < 0.001) and myocardial blood volume (MBV) (2.8 ± 0.9 mL/100 mL versus 4.2 ± 1.1 mL/100 mL, p = 0.044) compared with those of reference territories. MBF showed the best correlation with the level of peak hs-TnT (r = -0.682, p < 0.001), and MBV showed a moderate correlation with the level of peak hs-TnT (r = -0.437, p = 0.026); however, the other parameters did not show any significant correlation with hs-TnT levels. As for the association with LV function, only MBF was significantly correlated with LVEF at the time of admission (r = 0.469, p = 0.016) and at 6 months (r = 0.585, p = 0.001).
CONCLUSION: MBF quantified by dynamic CT-MPI is significantly inversely correlated with the level of peak hs-TnT. In addition, patients with lower MBF tended to have impaired LV function at the time of their admission and at 6 months.
引用
- Pan J, Yuan M, Yu M, et al. Myocardial Blood Flow Quantified by Low-Dose Dynamic CT Myocardial Perfusion Imaging Is Associated with Peak Troponin Level and Impaired Left Ventricle Function in Patients with ST-Elevated Myocardial Infarction. Korean J Radiol. 2019. PMID: 30993922. doi:10.3348/kjr.2018.0729
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。