文献速递心血管外周血管技术与安全CT

心血管CT检查的辐射暴露:传统64层MDCT与第三代双源MDCT的比较

Radiation exposure related to cardiovascular CT examination: comparison between conventional 64-MDCT and third-generation dual-source MDCT.
PubMed 文献 · Radiol Med · 2019-04-22

该回顾性研究纳入2017年1月至2018年8月行心血管CT检查的1458例患者,比较传统64-MDCT与第三代双源MDCT的辐射剂量与扫描参数。双源CT组冠状动脉检查的CTDIvol、DLP和ED分别降低24.4%、35.6%和35.6%,血管检查的CTDIvol降低43.5%至70.6%。作者结论认为在日常实践中双源CT的剂量指标和曝光时间更低、螺距因子更高。

要点

  • 第三代双源CT冠状动脉检查CTDIvol为23.1 mGy,较64-MDCT的30.6 mGy降低24.4%。
  • 双源CT冠状动脉检查DLP为465.0 mGy·cm、ED为6.5 mSv,较64-MDCT的732.3 mGy·cm和10.3 mSv均降低35.6%。
  • 血管检查中双源CT的CTDIvol降低43.5%至70.6%,DLP和ED降低50.3%至73.1%。

核心结论

  • 在日常实践中,192×2-DSCT较64-MDCT的心血管检查CTDI、DLP、ED、曝光时间和管电压更低,螺距因子更高。

研究设计与样本

  • 回顾性研究,纳入2017年1月至2018年8月行心血管检查的1458例患者。
  • 705例于2017年1月至8月行单源64-MDCT(Lightspeed VCT,GE)检查,其中冠状动脉检查207例、血管检查498例。
  • 753例于2018年1月至8月行第三代192×2-DSCT(Somatom FORCE,Siemens)检查,其中冠状动脉检查302例、血管检查451例。
  • 记录每位患者的CTDIvol、DLP、ED、管电压、曝光时间和螺距因子,采用Student t检验比较对应组均值。

诊断标准与关键数值

  • 冠状动脉检查:双源CT的CTDIvol为23.1 mGy,64-MDCT为30.6 mGy,双源CT降低24.4%(p<0.0001)。
  • 冠状动脉检查:双源CT的DLP为465.0 mGy·cm、ED为6.5 mSv,64-MDCT的DLP为732.3 mGy·cm、ED为10.3 mSv,双源CT的DLP和ED均降低35.6%(p<0.0001)。
  • 冠状动脉检查:双源CT的kVp和曝光时间分别降低12.7%和69.4%,螺距因子升高73.8%(p<0.0001)。
  • 全部血管检查:双源CT较64-MDCT的CTDIvol降低43.5%至70.6%,DLP和ED降低50.3%至73.1%,kVp降低10.7%至32.5%,曝光时间降低26.3%至68.7%,螺距因子升高16.7%至58.1%(所有差异p<0.0001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare radiation exposure associated with daily practice cardiovascular (CV) examinations performed on two different multidetector computed tomography (MDCT) scanners, a conventional 64-MDCT and a third-generation dual-source (DS) MDCT.

MATERIALS AND METHODS: In this retrospective study, 1458 patients who underwent CV examinations between January 2017 and August 2018 were enrolled. A single-source 64-MDCT (Lightspeed VCT, GE) scan was performed in 705 patients from January to August 2017 (207 coronary examinations and 498 vascular examinations) and 753 patients underwent third-generation 192 × 2-DSCT (Somatom FORCE, Siemens) scan from January to August 2018 (302 coronary examinations and 451 vascular examinations). Volume CT dose index (CTDIvol), dose length product (DLP), effective dose (ED), tube voltage (TV) and exposure time (ET), pitch factor (PF) were registered for each patient. Student's t test was used to compare mean values between each corresponding group of MDCT and DSCT.

RESULTS: In coronary examinations with DSCT, CTDIvol was 24.4% lower (23.1 mGy vs 30.6 mGy, p < 0.0001) and DLP and ED reductions were 35.6% than with MDCT (465.0 mGy * cm vs 732.3 mGy * cm and 6.5 mSv and 10.3 mSv; vs p < 0.0001). Concerning scan parameters, kVp and ET reductions were 12.7% and 69.4%, respectively (p < 0.0001); PF increase was 73.8% (p < 0.0001). In all vascular studies, DSCT, compared with MDCT, permitted to reduce CTDIvol from 43.5 to 70.6%; DLP and ED reductions were from 50.3 to 73.1%; kVp and ET decreases were from 10.7 to 32.5% and from 26.3 to 68.7%. PF increase was from 16.7 to 58.1% (all differences with p < 0.0001).

CONCLUSIONS: In daily practice, CV examinations CTDI, DLP, ED, ET and TV were lower and PF was higher with 192 × 2-DSCT compared to 64-MDCT.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Agliata G, Schicchi N, Agostini A, et al. Radiation exposure related to cardiovascular CT examination: comparison between conventional 64-MDCT and third-generation dual-source MDCT. Radiol Med. 2019. PMID: 31011995. doi:10.1007/s11547-019-01036-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。