文献速递心血管外周血管US

冠状动脉粥样硬化的生物力学应力分析:识别多因素指标以评估斑块破裂风险

Biomechanical Stress Profiling of Coronary Atherosclerosis: Identifying a Multifactorial Metric to Evaluate Plaque Rupture Risk.
PubMed 文献 · JACC Cardiovasc Imaging · 2019-04-17

本研究基于30例患者的61处坏死核心纤维粥样斑块,用多因素回归建立应力方程计算峰值应力指标,该指标与有限元模型峰值应力高度相关(R=0.85,p<0.0001),并在3例附加患者中精确定位破裂部位;作者认为该方程有望快速计算峰值应力,但需进一步研究用于预后评估。

要点

  • 纤维帽厚度、坏死核心角度与厚度、管腔面积、坏死核心含钙化面积、斑块面积与峰值应力独立相关。
  • 多因素应力方程计算的峰值应力指标与有限元模型峰值应力高度相关(R=0.85,p<0.0001)。
  • 仅56%(n=34)斑块中最薄纤维帽厚度是确定最高峰值应力截面的决定参数。

核心结论

  • 多因素应力方程有望快速计算冠状动脉病变的峰值应力指标,但需进一步研究以探讨生物力学应力分析用于动脉粥样硬化患者预后评估。

研究设计与样本

  • 研究在30例患者中行血管内超声和光学频域成像,在61处坏死核心纤维粥样斑块中定义斑块形态参数,用多因素回归推导多因素应力方程并计算峰值应力指标,以有限元模型峰值应力为参考标准验证其准确性,另在3例患者中测试其定位斑块破裂部位的能力。

诊断标准与关键数值

  • 与峰值应力独立相关的参数:纤维帽厚度(p<0.0001)、坏死核心角度(p=0.024)、坏死核心厚度(p<0.0001)、管腔面积(p<0.0001)、坏死核心含钙化面积(p=0.017)、斑块面积(p=0.003)。
  • 峰值应力指标与有限元模型峰值应力高度相关(R=0.85;p<0.0001),证实多因素应力方程的准确性。
  • 仅56%(n=34)斑块中最薄纤维帽厚度是识别最高峰值应力截面的决定参数。
  • 在含斑块破裂的冠状动脉节段,多因素应力方程精确定位破裂部位。

临床应用与阅片要点

  • 阅片时需综合纤维帽厚度、坏死核心角度与厚度、管腔面积、坏死核心含钙化面积及斑块面积等多因素评估峰值应力,而非仅依赖最薄纤维帽厚度。
  • 在含斑块破裂的节段,多因素应力方程可精确定位破裂部位。
  • 作者认为多因素应力方程有望快速计算峰值应力指标,但需进一步研究探讨其用于预后评估。

局限性

  • 作者指出需进一步研究以探讨生物力学应力分析用于动脉粥样硬化患者预后评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The purpose of this study was to derive a biomechanical stress metric that was based on the multifactorial assessment of coronary plaque morphology, likely related to the propensity of plaque rupture in patients.

BACKGROUND: Plaque rupture, the most frequent cause of coronary thrombosis, occurs at locations of elevated tensile stress in necrotic core fibroatheromas (NCFAs). Finite element modeling (FEM), typically used to calculate tensile stress, is computationally intensive and impractical as a clinical tool for locating rupture-prone plaques. This study derived a multifactorial stress equation (MSE) that accurately computes peak stress in NCFAs by combining the influence of several morphological parameters.

METHODS: Intravascular ultrasound and optical frequency domain imaging were conducted in 30 patients, and plaque morphological parameters were defined in 61 NCFAs. Multivariate regression analysis was applied to derive the MSE and compute a peak stress metric (PSM) that was based on the analysis of plaque morphological parameters. The accuracy of the MSE was determined by comparing PSM with FEM-derived peak stress values. The ability of the PSM in locating plaque rupture sites was tested in 3 additional patients.

RESULTS: The following parameters were found to be independently associated with peak stress: fibrous cap thickness (p < 0.0001), necrotic core angle (p = 0.024), necrotic core thickness (p < 0.0001), lumen area (p < 0.0001), necrotic core including calcium areas (p = 0.017), and plaque area (p = 0.003). The PSM showed excellent correlation (R = 0.85; p < 0.0001) with FEM-derived peak stress, thus confirming the accuracy of the MSE. In only 56% (n = 34) of plaques, the thinnest fibrous cap thickness was a determining parameter in identifying the cross section with highest PSM. In coronary segments with plaque ruptures, the MSE precisely located the rupture site.

CONCLUSIONS: The MSE shows potential to calculate the PSM in coronary lesions rapidly. However, further studies are warranted to investigate the use of biomechanical stress profiling for the prognostic evaluation of patients with atherosclerosis.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Doradla P, Otsuka K, Nadkarni A, et al. Biomechanical Stress Profiling of Coronary Atherosclerosis: Identifying a Multifactorial Metric to Evaluate Plaque Rupture Risk. JACC Cardiovasc Imaging. 2019. PMID: 31005542. doi:10.1016/j.jcmg.2019.01.033

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。