文献速递心血管CT

基于知识迭代模型重建的冠状动脉CT血管成像评估冠状动脉及非钙化为主斑块

Coronary CT Angiography with Knowledge-Based Iterative Model Reconstruction for Assessing Coronary Arteries and Non-Calcified Predominant Plaques.
PubMed 文献 · Korean J Radiol · 2019-01-01

纳入66例单支病变且以非钙化斑块为主的患者,行前瞻性心电门控256层CT血管成像,比较混合迭代重建(HIR)与迭代模型重建(IMR)对斑块特征的显示。IMR检出40个餐巾环征斑块而HIR仅19个,两者差异有统计学意义;IMR图像噪声低于HIR,SNR、CNR及斑块与周围脂肪CNR均优于HIR。

要点

  • IMR较HIR能更多显示餐巾环征(40个 vs 19个,p<0.001),阅片时注意重建算法对高危斑块征象识别的影响。
  • 正性重构、低衰减斑块、点状钙化在HIR与IMR间无统计学显著差异(均p>0.5)。
  • IMR图像噪声更低(10±2 HU vs 12±2 HU),SNR、CNR及斑块与脂肪CNR均优于HIR(p<0.01)。

核心结论

  • 与HIR相比,IMR可显著改善256层CT显示冠状动脉及动脉粥样硬化斑块的图像质量。

研究设计与样本

  • 单中心研究纳入66例(男53例、女13例,年龄39-76岁,平均55±13岁)单支病变且以非钙化斑块为主的患者,行前瞻性心电门控256层CT血管成像,分别用HIR与IMR重建配对图像集进行比较。

关键影像表现/征象

  • 共检出77个以非钙化为主的斑块;IMR重建显示40个斑块呈餐巾环征,HIR重建显示19个斑块呈餐巾环征。

诊断标准与关键数值

  • 正性重构、低衰减斑块、点状钙化在HIR与IMR间的显示差异均无统计学意义(均p>0.5);餐巾环征显示差异有统计学意义(χ²=12.12,p<0.001)。

临床应用与阅片要点

  • 日常冠脉CT报告中描述餐巾环征时需注意所用重建算法,IMR较HIR更易显示该征象(40个 vs 19个);正性重构、低衰减斑块、点状钙化的判读在两种算法间无统计学显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess the effects of iterative model reconstruction (IMR) on image quality for demonstrating non-calcific high-risk plaque characteristics of coronary arteries.

MATERIALS AND METHODS: This study included 66 patients (53 men and 13 women; aged 39-76 years; mean age, 55 ± 13 years) having single-vessel disease with predominantly non-calcified plaques evaluated using prospective electrocardiogram-gated 256-slice CT angiography. Paired image sets were created using two types of reconstruction: hybrid iterative reconstruction (HIR) and IMR. Plaque characteristics were compared using the two algorithms. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the images and the CNR between the plaque and adjacent adipose tissue were also compared between the two reformatted methods.

RESULTS: Seventy-seven predominantly non-calcified plaques were detected. Forty plaques showed napkin-ring sign with the IMR reformatted method, while nineteen plaques demonstrated napkin-ring sign with HIR. There was no statistically significant difference in the presentation of positive remodeling, low attenuation plaque, and spotty calcification between the HIR and IMR reconstructed methods (all p > 0.5); however, there was a statistically significant difference in the ability to discern the napkin-ring sign between the two algorithms (χ² = 12.12, p < 0.001). The image noise of IMR was lower than that of HIR (10 ± 2 HU versus 12 ± 2 HU; p < 0.01), and the SNR and CNR of the images and the CNR between plaques and surrounding adipose tissues on IMR were better than those on HIR (p < 0.01).

CONCLUSION: IMR can significantly improve image quality compared with HIR for the demonstration of coronary artery and atherosclerotic plaques using a 256-slice CT.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Li T, Tang T, Yang L, et al. Coronary CT Angiography with Knowledge-Based Iterative Model Reconstruction for Assessing Coronary Arteries and Non-Calcified Predominant Plaques. Korean J Radiol. 2019. PMID: 30993924. doi:10.3348/kjr.2018.0435

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。