IA期肺腺癌临床T分期:实性部分测量的CT显示窗设置对预后影响
回顾性分析691例2009至2015年手术治疗的临床IA期肺腺癌患者,分别在肺窗和纵隔窗测量实性部分并确定cT分期(cTlung与cTmediastinum),比较两者对无病生存的预后价值。两种窗设置cT分期的预后效能无显著差异(C-index 0.772 vs 0.787,p=0.789),基于肺窗测量的现行cT分期是合适的。
要点
- 肺窗与纵隔窗测量的cT分期对无病生存的预后判别能力无显著差异(C-index 0.772 vs 0.787,p=0.789)。
- 纵隔窗实性部分最佳cT分级截断值为0.9 cm和1.8 cm,但其预后效能与肺窗及纵隔窗常规cT分期均无显著差异(p>0.05)。
- 肺窗设置对实性部分的检测更敏感且与病理浸润成分相关性更高,支持按现行建议继续使用肺窗测量实性部分。
核心结论
- 肺窗与纵隔窗cT分期的预后效能无显著差异,基于肺窗测量的现行cT分期是合适的。
研究设计与样本
- 回顾性分析2009至2015年691例手术治疗的临床IA期肺腺癌患者,分别于肺窗和纵隔窗测量实性部分并确定cTlung和cTmediastinum,以Cox回归评估无病生存预后,C-index用Student t检验比较,并拆分训练集与验证集计算纵隔窗实性部分的最佳cT分级截断值(cToptimal)并验证其预后效能。
诊断标准与关键数值
- 多变量Cox模型中cTlung与无病生存显著相关:cT1b校正HR 3.547(p=0.017),cT1c校正HR 9.439(p<0.001)。
- 多变量Cox模型中cTmediastinum与无病生存显著相关:cT1b校正HR 4.635(p<0.001),cT1c校正HR 11.235(p<0.001)。
- cTlung的C-index为0.772(95%CI 0.702-0.842),cTmediastinum为0.787(95%CI 0.726-0.848),两者比较p=0.789。
- 纵隔窗实性部分cT分级的最佳截断值为0.9 cm和1.8 cm。
- cTlung、cTmediastinum与cToptimal三者的C-index之间无显著差异(p>0.05)。
临床应用与阅片要点
- 作者认为,鉴于肺窗设置对实性部分的检测更敏感且与病理浸润成分相关性更高,本研究结果可能支持按现行建议继续使用肺窗测量实性部分。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Our study aimed at evaluating the prognostic implications of lung and mediastinal CT display window settings for solid portion measurements on the eighth-edition lung cancer staging system's clinical T (cT) categorization.
METHODS: We retrospectively analyzed 691 surgically treated patients from 2009 to 2015 for clinical stage IA lung adenocarcinomas. Solid portions were measured at the lung and mediastinal window settings, respectively, and cT categories were determined for each measurement (cTlung and cTmediastinum). The prognostic power of the two cT factors for disease-free survival (DFS) was assessed using Cox regression, and concordance indices (C-indices) were compared using the Student t test. Subsequently, the patients were split into training and validation cohorts to calculate optimal cutoffs for the cT categorization of mediastinal window-based solid portions (cToptimal) and validate its prognostic performance.
RESULTS: Both cTlung ((cT1b: adjusted HR, 3.547; p = 0.017), (cT1c: adjusted HR, 9.439; p < 0.001)) and cTmediastinum ((cT1b: adjusted HR, 4.635; p < 0.001), (cT1c: adjusted HR, 11.235; p < 0.001)) were significantly associated with DFS for each multivariable Cox model. The C-indices were 0.772 (95% CI, 0.702-0.842) for cTlung and 0.787 (95% CI, 0.726-0.848) for cTmediastinum (p = 0.789). The optimal cutoffs for cT categorization of the mediastinal window-based solid portions were 0.9 cm and 1.8 cm. However, there were no significant differences in the C-indices among cTlung, cTmediastinum, and cToptimal (p > 0.05).
CONCLUSIONS: The prognostic performances of the cT categorizations at the lung and mediastinal windows were not significantly different. The current cT categorization based on the lung window measurement is appropriate as it stands.
KEY POINTS: • Discriminatory power of the eighth-edition clinical T category was not significantly affected by the CT display window settings. • Given the facts that the lung window setting enables more sensitive detection of the solid portions and higher correlation with the pathological invasive components, our findings may support adherence to the usage of the lung window setting for the solid portion measurement per the current recommendations.
引用
- Kim H, Goo JM, Kim YT, et al. Clinical T categorization in stage IA lung adenocarcinomas: prognostic implications of CT display window settings for solid portion measurement. Eur Radiol. 2019. PMID: 31016444. doi:10.1007/s00330-019-06216-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。