文献速递胸部技术与安全CTPET

采用浅呼吸模式下的电影平均CT减少胸部PET/CT扫描中呼吸运动伪影

Using Cine-Averaged CT With the Shallow Breathing Pattern to Reduce Respiration-Induced Artifacts for Thoracic Cavity PET/CT Scans.
PubMed 文献 · AJR Am J Roentgenol · 2019-04-01

研究纳入30例癌症患者,在常规PET/CT后加做胸部电影平均CT(CACT),比较PET/螺旋CT(HCT)与PET/CACT的配准误差及SUVmax。结果显示PET/HCT所有病灶配准误差均大于5 mm,而PET/CACT仅33%大于5 mm;CACT可减少配准不良并恢复被低估的SUVmax。

要点

  • PET/HCT图像所有病灶配准误差均大于5 mm,PET/CACT仅33%病灶大于5 mm。
  • CACT结合浅呼吸模式可减少胸部PET/CT病灶配准不良并恢复被低估的SUVmax。

核心结论

  • 使用CACT技术及浅呼吸模式可有效减少病灶配准不良并恢复被低估的SUVmax,CACT方法可应用于胸部PET/CT临床实践以改善癌症管理。

研究设计与样本

  • 30例癌症患者接受常规PET/CT后行胸部CACT,计算PET/HCT与PET/CACT间的配准误差,并以HCT和CACT图像分别对PET数据做衰减校正后评估SUVmax。

关键影像表现/征象

  • PET/HCT图像中所有病灶配准误差均大于5 mm,而PET/CACT图像中仅33%病灶配准误差大于5 mm。
  • PET/HCT与PET/CACT图像中病灶最大配准误差均值分别为14.10 ± 6.26 mm和5.92 ± 4.31 mm。

诊断标准与关键数值

  • 应用CACT后,7%的病灶SUVmax增加超过20%,47%的病灶SUVmax轻微增加小于5%。
  • CACT与HCT的SUVmax平均百分比差异为12%。

临床应用与阅片要点

  • CACT方法可应用于胸部PET/CT临床实践以改善癌症管理。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. PET/CT provides a fusion of both anatomic and functional information. However, because of the temporal difference of both modalities and respiratory motion of lungs, misregistration of lesions is frequently observed on thoracic PET/CT scans. The effect of cine-averaged CT (CACT) acquisition incorporated with the shallow breathing pattern of patients on the improvement of registration and quantification of lesions was investigated. MATERIALS AND METHODS. Thirty patients with cancer who underwent routine PET/CT followed by CACT of the thoracic region were enrolled. The misalignment between PET/helical CT (HCT) and PET/CACT was calculated. In addition, the PET data were attenuation-corrected by HCT and CACT images, and the maximum standardized uptake value (SUVmax) was evaluated. RESULTS. All lesions in the PET/HCT images showed misalignment larger than 5 mm, whereas only 33% of lesions in the PET/CACT images showed misalignment larger than 5 mm. The mean values of the maximum misalignment of the lesions in PET/HCT and PET/CACT images were 14.10 ± 6.26 mm and 5.92 ± 4.31 mm, respectively. Seven percent of the lesions had an increase in SUVmax of more than 20%, and 47% showed a slight increase in SUVmax of less than 5% after applying CACT. The mean percentage difference between the SUVmax of CACT and that of HCT was 12%. CONCLUSION. Using the CACT technique and the shallow breathing pattern effectively reduces misregistration of lesions and recovers the underestimated SUVmax. The CACT method can be applied in clinical practice of thoracic PET/CT for better cancer management.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Changlai SP, Huang CK, Luzhbin D, et al. Using Cine-Averaged CT With the Shallow Breathing Pattern to Reduce Respiration-Induced Artifacts for Thoracic Cavity PET/CT Scans. AJR Am J Roentgenol. 2019. PMID: 30933646. doi:10.2214/AJR.18.20606

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。