T1 mapping与固定T1法在脑胶质瘤动态对比增强MRI灌注中的比较
回顾性分析83例胶质瘤(46例低级别、37例高级别),比较固定T1值1400 ms与VFA测得T1值两种方法获得的DCE-MRI灌注参数。固定T1法所得灌注参数显著高于VFA法,但两种方法在胶质瘤分级和分子分型上的诊断准确率无显著差异(少数参数除外)。结论认为不同prebolus T1获得的DCE-MRI数据不可比较,且T1 mapping定义prebolus T1并非必需。
要点
- 固定T1值1400 ms所得Vp、Ve、Ktrans显著高于VFA测得T1值所得。
- 两种方法在胶质瘤分级和分子分型上诊断准确率无显著差异(少数参数除外)。
- 不同prebolus T1获得的DCE-MRI数据不可比较。
核心结论
- 不同prebolus T1获得的DCE-MRI数据不可比较;通过T1 mapping定义prebolus T1并非必需,因其未提高DCE-MRI对胶质瘤分级的诊断准确率;固定T1值是DCE-MRI分析中T1 mapping的有效替代方案。
研究设计与样本
- 回顾性分析83例胶质瘤,其中低级别胶质瘤(LGG;II和III级)46例、高级别胶质瘤(HGG;IV级)37例;分别采用固定T1值1400 ms和可变翻转角(VFA)测得的T1值获取DCE-MRI的Vp、Ve、Ktrans图;肿瘤分割后在与灌注图共配准的感兴趣体积(VOI)内提取一阶直方图参数;采用Wilcoxon配对符号秩检验和Bland-Altman分析比较两种方法;采用ROC曲线分析和DeLong检验获得并比较诊断准确率。
诊断标准与关键数值
- 固定T1值1400 ms与VFA测得T1值所得灌注参数比较:固定T1值所得参数显著高于VFA法。
- 胶质瘤分级和分子分类的诊断准确率:两种方法间无显著差异,仅少数参数例外。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare dynamic contrast-enhanced MRI (DCE-MRI) data obtained using different prebolus T1 values in glioma grading and molecular profiling.
METHODS: We retrospectively reviewed 83 cases of gliomas: 46 lower-grade gliomas (LGG; grades II and III) and 37 high-grade gliomas (HGG; grade IV). DCE-MRI maps of plasma volume fraction (Vp), extravascular-extracellular volume fraction (Ve), and tracer transfer constant from plasma to tissue (Ktrans) were obtained using a fixed T1 value of 1400 ms and a measured T1 obtained with variable flip angle (VFA). Tumour segmentations were performed and first-order histogram parameters were extracted from volumes of interest (VOIs) after co-registration with the perfusion maps. The two methods were compared using Wilcoxon matched-pairs signed-rank test and Bland-Altman analysis. Diagnostic accuracy was obtained and compared using ROC curve analysis and DeLong's test.
RESULTS: Perfusion parameters obtained with the fixed T1 value were significantly higher than those obtained with the VFA. As regards diagnostic accuracy, there were no significant differences between the two methods both for glioma grading and molecular classification, except for few parameters of both methods.
CONCLUSIONS: DCE-MRI data obtained with different prebolus T1 are not comparable and the definition of a prebolus T1 by T1 mapping is not mandatory since it does not improve the diagnostic accuracy of DCE-MRI.
KEY POINTS: • DCE-MRI data obtained with different prebolus T1 are significantly different, thus not comparable. • The definition of a prebolus T1 by T1 mapping is not mandatory since it does not improve the diagnostic accuracy of DCE-MRI for glioma grading. • The use of a fixed T1 value represents a valid alternative to T1 mapping for DCE-MRI analysis.
引用
- Conte GM, Altabella L, Castellano A, et al. Comparison of T1 mapping and fixed T1 method for dynamic contrast-enhanced MRI perfusion in brain gliomas. Eur Radiol. 2019. PMID: 30972545. doi:10.1007/s00330-019-06122-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。