文献速递神经MR

脑脊液引流后静脉血流射流速度降低:评估搏动性耳鸣的血流动力学原因

Reduced Jet Velocity in Venous Flow after CSF Drainage: Assessing Hemodynamic Causes of Pulsatile Tinnitus.
PubMed 文献 · AJNR Am J Neuroradiol · 2019-04-25

本研究对10例疑似横窦狭窄所致搏动性耳鸣的患者在同一次会话中于腰椎穿刺前后行MR成像,发现腰椎穿刺后静脉峰值速度降低且与开放压力相关(r=-0.72,P=.019),流速未见相应下降;有血流射流的患者峰值速度降低0.30±0.18 m/s(P=.002),且与脑脊液压力降低(r=0.82,P=.024)及搏动性耳鸣强度评分降低(r=0.78,P=.023)相关。作者推测速度降低源于穿刺后狭窄扩大,并提示血流射流可能参与声音产生。

要点

  • 腰椎穿刺后静脉峰值速度降低与开放压力相关(r=-0.72,P=.019),流速未见相应下降。
  • 有血流射流的患者峰值速度降低0.30±0.18 m/s(P=.002),与脑脊液压力降低及搏动性耳鸣强度评分降低相关。
  • 1例穿刺后MR静脉造影显示狭窄减轻。

核心结论

  • 腰椎穿刺引起静脉峰值速度降低而流速未见相应下降,作者推测该降低源于穿刺后狭窄扩大,且峰值速度与搏动性耳鸣强度相关,提示血流射流可能参与声音产生。

研究设计与样本

  • 10例疑似横窦狭窄作为搏动性耳鸣静脉病因的患者,在同一次会话中于腰椎穿刺前后行MR成像,方案包括血流评估、搏动性耳鸣强度评分(穿刺前后)及MR静脉造影(穿刺前),1例于穿刺后行MR静脉造影。

关键影像表现/征象

  • 腰椎穿刺后静脉峰值速度降低,与开放压力相关(r=-0.72,P=.019),流速未见相应下降。
  • 有血流射流的患者峰值速度降低0.30±0.18 m/s(P=.002)。
  • 峰值速度降低与脑脊液压力降低相关(r=0.82,P=.024)。
  • 峰值速度降低与主观搏动性耳鸣强度评分降低相关(r=0.78,P=.023)。
  • 1例穿刺后MR静脉造影显示狭窄减轻。

临床应用与阅片要点

  • 作者推测腰椎穿刺后静脉峰值速度降低源于狭窄扩大,并提示血流射流可能参与搏动性耳鸣声音产生。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Idiopathic intracranial hypertension is commonly associated with transverse sinus stenosis, a venous cause of pulsatile tinnitus. In patients with idiopathic intracranial hypertension, CSF drainage via lumbar puncture decreases intracranial pressure, which relieves the stenosis, and may provide at least temporary cessation of pulsatile tinnitus. The objective of this study was to evaluate changes in venous blood flow caused by lowered intracranial pressure in patients with pulsatile tinnitus to help identify the cause of pulsatile tinnitus.

MATERIALS AND METHODS: Ten patients with suspected transverse sinus stenosis as a venous etiology for pulsatile tinnitus symptoms underwent MR imaging before and after lumbar puncture in the same session. The protocol included flow assessment and rating of pulsatile tinnitus intensity before and after lumbar puncture and MR venography before lumbar puncture. Post-lumbar puncture MR venography was performed in 1 subject.

RESULTS: There was a lumbar puncture-induced reduction in venous peak velocity that correlated with the opening pressure (r = -0.72, P = .019) without a concomitant reduction in flow rate. Patients with flow jets had their peak velocity reduced by 0.30 ± 0.18 m/s (P = .002), correlating with a reduction in CSF pressure (r = 0.82, P = .024) and the reduction in subjectively scored pulsatile tinnitus intensity (r = 0.78, P = .023). The post-lumbar puncture MR venography demonstrated alleviation of the stenosis.

CONCLUSIONS: Our results show a lumbar puncture-induced reduction in venous peak velocity without a concomitant reduction in flow rate. We hypothesize that the reduction is caused by the expansion of the stenosis after lumbar puncture. Our results further show a correlation between the peak velocity and pulsatile tinnitus intensity, suggesting the flow jet to be instrumental in the development of sound.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Haraldsson H, Leach JR, Kao EI, et al. Reduced Jet Velocity in Venous Flow after CSF Drainage: Assessing Hemodynamic Causes of Pulsatile Tinnitus. AJNR Am J Neuroradiol. 2019. PMID: 31023664. doi:10.3174/ajnr.A6043

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。