文献速递神经介入DSA

支架辅助编织腔内桥装置治疗宽颈颅内动脉瘤:单中心经验

Treatment of Wide-Neck Intracranial Aneurysms with the Woven EndoBridge Device Associated with Stenting: A Single-Center Experience.
PubMed 文献 · AJNR Am J Neuroradiol · 2019-04-11

作者认为该策略技术可行且有效,相对安全,相关不良事件发生率低。

要点

  • 编织腔内桥联合支架可用于因解剖不利而需避免装置突入分叉分支的宽颈颅内动脉瘤。
  • 随访中完全闭塞(Raymond-Roy I)11例(69%)、近完全闭塞(Raymond-Roy II)2例(12.5%),Raymond-Roy III组动脉瘤平均尺寸更大(10±1 mm vs 5.5±2.1 mm,P=.003)。

核心结论

  • 编织腔内桥装置联合支架置入治疗解剖不利的颅内动脉瘤在技术上可行且有效,本研究中该策略相对安全,相关操作不良事件发生率低。

研究设计与样本

  • 单中心回顾性研究,采用前瞻性维护的数据,纳入17例接受编织腔内桥单层装置联合支架置入的动脉瘤患者,评估技术可行性、操作并发症、动脉瘤闭塞及临床结局。

关键影像表现/征象

  • 动脉瘤平均大小为7±3.1 mm,部位包括大脑中动脉10例、前交通动脉3例、基底动脉尖3例、后交通动脉1例。
  • 2例为破裂动脉瘤并在急性期治疗,术中2例蛛网膜下腔出血患者出现轻微且完全可逆的支架内血栓。
  • 随访发现1例无症状的角动脉闭塞,该例为远端非分叉部动脉瘤。

诊断标准与关键数值

  • 长期(10.4个月)血管造影完全闭塞(Raymond-Roy I)11例(69%),近完全闭塞(Raymond-Roy II)2例(12.5%)。
  • Raymond-Roy I/II组动脉瘤平均大小5.5±2.1 mm,Raymond-Roy III组10±1 mm(P=.003)。
  • 平均透视时间为35±14分钟。

临床应用与阅片要点

  • 对于因解剖不利可能导致编织腔内桥装置突入分叉分支的宽颈颅内动脉瘤,可考虑联合支架置入。
  • 术后血管造影随访需关注支架内血栓及分支血管闭塞等事件。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: The intrasaccular flow disruptor, the Woven EndoBridge device, is increasingly used for the treatment of wide-neck intracranial aneurysms. Due to unfavorable anatomy, additional stent placement is sometimes required to avoid Woven EndoBridge protrusion into bifurcation branches. We report our experience with the Woven EndoBridge associated with stent placement for the treatment of complex intracranial aneurysms.

MATERIALS AND METHODS: Patients with aneurysms treated with the Woven EndoBridge Single-Layer plus stent placement were evaluated retrospectively with prospectively maintained data. The technical feasibility, procedural complications, aneurysm occlusion, and clinical outcome were studied.

RESULTS: Seventeen patients and aneurysms treated with the Woven EndoBridge plus stent placement were included. The mean aneurysm size was 7 ± 3.1 mm. Aneurysm locations were the following: MCA (10 patients), anterior communicating artery (3 patients), basilar tip (3 patients), and posterior communicating artery (1 patient). Two lesions were ruptured and treated in the acute phase. The Woven EndoBridge and stent placement were successfully delivered in all cases. There were no permanent/major complications. Among the 2 patients with SAH, minor and completely reversible in-stent thrombosis occurred during treatment. An asymptomatic occlusion of the angular artery with a distal nonbifurcation aneurysm was discovered during the angiographic follow-up. Long-term (10.4 months) angiographic complete (Raymond-Roy I) and near-complete (Raymond-Roy II) occlusion was obtained in 11 (69%) and 2 (12.5%) aneurysms, respectively. The mean sizes of aneurysms showing Raymond-Roy I/Raymond-Roy II and Raymond-Roy III occlusion were 5.5 ± 2.1 mm and 10 ± 1 mm, respectively (P = .003). The mean fluoroscopy time was 35 ± 14 minutes.

CONCLUSIONS: Aneurysm embolization with the Woven EndoBridge device associated with stent placement appears technically feasible and effective for the treatment of lesions with unfavorable anatomy. In our study, this strategy was relatively safe with a low rate of relevant procedure-related adverse events.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Cagnazzo F, Ahmed R, Dargazanli C, et al. Treatment of Wide-Neck Intracranial Aneurysms with the Woven EndoBridge Device Associated with Stenting: A Single-Center Experience. AJNR Am J Neuroradiol. 2019. PMID: 30975649. doi:10.3174/ajnr.A6032

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。