应用表观扩散系数无创评估弥漫性中线胶质瘤H3 K27M突变状态

Noninvasive assessment of H3 K27M mutational status in diffuse midline gliomas by using apparent diffusion coefficient measurements.
PubMed 文献 · Eur J Radiol · 2019-03-14

回顾性分析38例脑弥漫性中线胶质瘤患者术前常规MRI和DWI,测量最小ADC、瘤周ADC及其比值,比较H3 K27M突变型与野生型差异。突变型各项ADC值均显著低于野生型(P<0.05),最小ADC比值联合瘤周ADC比值诊断突变状态的AUC最大为0.872,提示可无创检测H3 K27M突变状态。

要点

  • H3 K27M突变型弥漫性中线胶质瘤最小ADC、瘤周ADC及其比值均显著低于野生型(P<0.05)。
  • 最小ADC比值联合瘤周ADC比值诊断H3 K27M突变状态的AUC最大为0.872。
  • 不同部位的H3 K27M突变型胶质瘤影像特征多样,阅片需结合部位综合判断。

核心结论

  • 最小ADC比值联合瘤周ADC比值可无创检测脑弥漫性中线胶质瘤的H3 K27M突变状态。

研究设计与样本

  • 回顾性研究,纳入38例脑弥漫性中线胶质瘤患者,评估术前常规MRI参数,采用受试者工作特征曲线及校正年龄和肿瘤位置的logistic回归分析评估诊断效能。

关键影像表现/征象

  • 不同部位的H3 K27M突变型胶质瘤具有多样的影像学特征。

诊断标准与关键数值

  • H3 K27M突变型胶质瘤的最小ADC、瘤周ADC、最小ADC比值及瘤周ADC比值均显著低于野生型(P<0.05)。
  • 最小ADC比值联合瘤周ADC比值诊断H3 K27M突变状态的AUC最大为0.872。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: H3 K27M-mutant diffuse midline gliomas are associated with worse prognosis than H3 K27M wild-type gliomas. In the present study, we sought to evaluate the conventional magnetic resonance imaging (cMRI) of H3 K27M-mutant glioma and examine whether diffusion-weighted imaging (DWI) derived apparent diffusion coefficient (ADC) could noninvasively predict H3 K27M mutational status in brain diffuse midline gliomas.

MATERIALS AND METHODS: The institutional review board approved this study and waived the requirement for informed consent. Thirty-eight patients with brain diffuse midline gliomas were retrospectively reviewed. The parameters of preoperative cMRI were evaluated. The minimal ADC, peritumoral ADC, ratio of minimal ADC, and ratio of peritumoral ADC were measured, and significant differences between the two groups were identified by logistic regression analysis adjusted for age and tumor location. Receiver operating characteristic curves and logistic regression analysis adjusted for age and tumor location were used to assess the diagnostic performances of the minimal ADC, peritumoral ADC, ratio of minimal ADC, and ratio of peritumoral ADC.

RESULTS: H3 K27M-mutant gliomas in different locations have diverse imaging characteristics. Minimal ADC, peritumoral ADC, ratio of minimal ADC, and ratio of peritumoral ADC values were significantly lower in the H3 K27M-mutant gliomas than in the wild-type gliomas (P < 0.05). The combination of ratio of minimal ADC and ratio of peritumoral ADC provided the largest area under the curve (AUC) of 0.872 in defining H3 K27M-mutational status.

CONCLUSIONS: The combination of ratio of minimal ADC and ratio of peritumoral ADC can noninvasively detect the H3 K27M mutational status in brain diffuse midline gliomas.