加速选择性动脉自旋标记MR血管成像用于脑动静脉畸形可视化
本研究以21例脑动静脉畸形患者为对象,对比加速选择性动脉自旋标记(AccASL)与时间飞跃法(TOF)MR血管成像在显示畸形血管团、供血动脉、引流静脉及Spetzler-Martin分级方面与DSA的一致性。结果显示AccASL对AVM的检出率、各组成部分可视化评分及畸形团和引流静脉的对比噪声比均高于TOF,且无需使用对比剂即可辅助分级。
要点
- AccASL对脑AVM的检出率(观察者1为95.2%,观察者2为90.5%)高于TOF(分别为76.2%和71.4%)。
- AccASL在供血动脉、畸形团和引流静脉的可视化评分均高于TOF,其中引流静脉评分差异最明显(4.6±1.0 vs 2.2±1.1)。
- AccASL畸形团和引流静脉的对比噪声比均高于TOF,且无需使用对比剂即可辅助Spetzler-Martin分级。
核心结论
- 与TOF相比,AccASL能更好地显示脑AVM,且无需使用对比剂即可辅助分级。
研究设计与样本
- 21例脑AVM患者(平均年龄31.1±18.6岁;男11例,女10例)接受TOF和AccASL MR血管成像及DSA检查,由两名神经放射学医师以DSA为参考进行观察者研究。
关键影像表现/征象
- AccASL对供血动脉的可视化评分高于TOF(4.5±1.0 vs 3.9±1.5,p=0.0214)。
- AccASL对畸形团的可视化评分高于TOF(4.6±1.1 vs 3.2±1.5,p=0.0006)。
- AccASL对引流静脉的可视化评分高于TOF(4.6±1.0 vs 2.2±1.1,p<0.0001)。
- AccASL畸形团的对比噪声比高于TOF(29.9±16.7 vs 20.8±16.5,p=0.0002)。
- AccASL引流静脉的对比噪声比高于TOF(23.2±13.0 vs 12.6±12.0,p=0.0010)。
诊断标准与关键数值
- 观察者1 AccASL与DSA在功能部位、静脉引流模式和Spetzler-Martin分级的一致性几乎完美;观察者2在静脉引流模式为中等一致,在功能部位和Spetzler-Martin分级为高度一致。
- 观察者1 AccASL检出AVM的比例为95.2%,TOF为76.2%;观察者2 AccASL为90.5%,TOF为71.4%。
临床应用与阅片要点
- AccASL可用于脑AVM的无对比剂MR血管成像评估,对供血动脉、畸形团和引流静脉的显示优于TOF。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the performance of acceleration-selective arterial spin labeling (AccASL) MR angiography in the visualization of brain arteriovenous malformations (AVMs) in comparison with digital subtraction angiography (DSA) and time-of-flight (TOF) MR angiography.
METHODS: Twenty-one patients with brain AVM (mean age 31.1 ± 18.6 years; 11 males, 10 females) underwent TOF and AccASL MR angiography and DSA. Two neuroradiologists conducted an observer study for detection, nidus size, eloquence, venous drainage pattern, and Spetzler-Martin (SM) grade. The evaluations included the visualization of each AVM component with reference to DSA and assessments of contrast-to-noise ratio (CNR). The kappa statistic, repeated measures analysis of variance, Wilcoxon matched pairs test, and paired t test were used.
RESULTS: Both observers detected more AVMs with AccASL (95.2%, 90.5% for Observers 1 and 2) than with TOF (76.2% and 71.4%, respectively). The inter-modality agreement between AccASL and DSA was almost perfect for the eloquence, venous drainage pattern, and SM grade for Observer 1 and moderate for the venous drainage pattern and substantial for the eloquence and SM grade for Observer 2. The visualization scores were higher with AccASL than with TOF for the feeding artery (AccASL, 4.5 ± 1.0 vs. TOF, 3.9 ± 1.5, p = 0.0214), nidus (4.6 ± 1.1 vs. 3.2 ± 1.5, p = 0.0006), and draining vein (4.6 ± 1.0 vs. 2.2 ± 1.1, p < 0.0001), respectively. The CNRs in the nidus were higher in AccASL than in TOF (29.9 ± 16.7 vs. 20.8 ± 16.5, p = 0.0002), as in the draining vein (23.2 ± 13.0 vs. 12.6 ± 12.0, p = 0.0010), respectively.
CONCLUSIONS: AccASL better visualized brain AVMs compared with TOF and was useful for grading without the use of contrast agents.
引用
- Togao O, Hiwatashi A, Yamashita K, et al. Acceleration-selective arterial spin labeling MR angiography for visualization of brain arteriovenous malformations. Neuroradiology. 2019. PMID: 31016367. doi:10.1007/s00234-019-02217-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。