颅内恶性肿瘤中血氧水平依赖反应对高氧刺激的依赖性与气体给药顺序有关
本研究在3特斯拉下对8例患者进行静息及吸入高氧/高碳酸气体混合物的T2*定量,随机分为两种气体给药顺序组。结果显示对比增强病灶对氧气的反应强烈(+20.7%)且与气体方案无关(p=0.482),但对卡波金(carbogen)的反应显著依赖于给药顺序(A组+18.6% vs B组-6.4%,p=0.042)。结论提示气体给药方案是解释异常血管生长区域T2*反应的重要因素。
要点
- 对比增强脑肿瘤病灶对氧气吸入的T2*反应强烈(+20.7%),且不受气体给药顺序影响(p=0.482)。
- 对卡波金的T2*反应显著依赖给药顺序:A组+18.6% vs B组-6.4%(p=0.042)。
- 水肿区在氧气吸入时两组趋势不同:A组-9.9% vs B组+19.5%(p=0.057)。
核心结论
- 初步结果显示对比增强脑肿瘤病灶的T2*反应依赖于气体给药顺序,气体给药方案是解释异常血管生长区域T2*反应的重要因素。
研究设计与样本
- 在3特斯拉下对8例知情同意患者进行静息及吸入高氧/高碳酸气体混合物期间的T2*定量,随机分为两组接受不同气体给药方案(A组:医用空气-纯氧-卡波金;B组:医用空气-卡波金-纯氧),采用Mann-Whitney U检验和Wilcoxon符号秩检验分别验证呼吸刺激或不同组间T2*差异。
关键影像表现/征象
- 灰质和白质静息T2*值分别为50.3 ± 2.6 ms和46.1 ± 2.0 ms,刺激期间轻度升高。
- 肿瘤区域静息T2*值:坏死=74.1 ± 10.1 ms;水肿=60.3 ± 17.6 ms;对比增强病灶=48.6 ± 20.7 ms;实性T2高信号病灶=45.0 ± 3.0 ms。
临床应用与阅片要点
- 对比增强脑肿瘤病灶对氧气吸入的T2*反应强烈(+20.7%),且与气体给药顺序无关(p=0.482)。
- 对卡波金的T2*反应显著依赖给药顺序:A组+18.6% vs B组-6.4%(p=0.042)。
- 水肿区在氧气吸入时两组趋势不同:A组-9.9% vs B组+19.5%(p=0.057)。
局限性
- 原文标题及摘要中标注为初步结果(Preliminary results)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Literature reports contradicting results on the response of brain tumors to vascular stimuli measured in T2*-weighted MRI. Here, we analyzed the potential dependency of the MRI-response to (hypercapnic) hyperoxia on the order of the gas administration.
METHODS: T2* values were quantified at 3 Tesla in eight consenting patients at rest and during inhalation of hyperoxic/hypercapnic gas mixtures. Patients were randomly divided into two groups undergoing different gas administration protocols (group A: medical air-pure oxygen-carbogen; group B: medical air-carbogen-pure oxygen). Mann-Whitney U test and Wilcoxon signed rank test have been used to proof differences in T2* regarding respiratory challenge or different groups, respectively.
RESULTS: T2* values at rest for gray and white matter were 50.3 ± 2.6 ms and 46.1 ± 2.0 ms, respectively, and slightly increased during challenge. In tumor areas, T2* at rest were: necrosis = 74.1 ± 10.1 ms; edema = 60.3 ± 17.6 ms; contrast-enhancing lesions = 48.6 ± 20.7 ms; and solid T2-hyperintense lesions = 45.0 ± 3.0 ms. Contrast-enhancing lesions strongly responded to oxygen (+ 20.7%) regardless on the gas protocol (p = 0.482). However, the response to carbogen significantly depended on the order of gas administration (group A, + 18.6%; group B, - 6.4%, p = 0.042). In edemas, a different trend between group was found when breathing oxygen (group A, - 9.9%; group B, + 19.5%, p = 0.057).
CONCLUSION: Preliminary results show a dependency of the T2* response of contrast-enhancing brain tumor lesions on the order of the gas administration. The gas administration protocol is an important factor in the interpretation of the T2*-response in areas of abnormal vascular growth.
引用
- Stieb S, Riesterer O, Boss A, et al. Dependency of the blood oxygen level dependent-response to hyperoxic challenges on the order of gas administration in intracranial malignancies. Neuroradiology. 2019. PMID: 30949747. doi:10.1007/s00234-019-02200-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。