美国心脏病学会联合多家学会发布共识文件,推荐心血管医学中电离辐射的最佳实践。本综述面向心脏麻醉医师总结要点:患者和操作者辐射暴露应尽可能低;推荐穿戴至少0.25毫米铅当量的防护服(围裙、背心、颈围和眼镜),强烈推荐加用便携式屏蔽;应保持与X射线源的最大允许距离;最好通过颈部和围裙下胶片徽章监测辐射暴露;0.5毫米铅当量围裙预计可屏蔽约95%的辐射;采用这些建议后,麻醉医师应能将辐射暴露保持在每年20毫西弗以下(国际辐射防护委员会推荐)。

要点

  • 推荐穿戴至少0.25毫米铅当量的防护服(围裙、背心、颈围和眼镜)。
  • 强烈推荐加用便携式屏蔽。
  • 0.5毫米铅当量围裙预计可屏蔽约95%的辐射。

核心结论

  • 采用推荐的防护措施(至少0.25毫米铅当量防护服、便携式屏蔽、最大距离、双徽章监测)后,麻醉医师应能将辐射暴露保持在每年20毫西弗以下。

研究设计与样本

  • 美国心脏病学会联合美国核心脏病学会、心律学会、Mended Hearts、北美心血管影像学会、心血管造影和介入学会、心血管计算机断层扫描学会及核医学和分子影像学会发布的专家共识文件,本综述总结其与麻醉医师相关的要点。

诊断标准与关键数值

  • 推荐穿戴至少0.25毫米铅或铅当量的防护服,包括围裙、背心、颈围和眼镜。
  • 强烈推荐加用便携式屏蔽。
  • 0.5毫米铅当量围裙预计可屏蔽约95%的辐射。
  • 最好通过颈部和围裙下胶片徽章监测辐射暴露。
  • 采用这些建议后,麻醉医师应能将辐射暴露保持在每年20毫西弗以下(国际辐射防护委员会推荐)。

临床应用与阅片要点

  • 麻醉医师应保持与X射线源的最大允许距离,记住辐射强度与距X射线源距离的平方成反比。
  • 患者和操作者的辐射暴露应尽可能低(ALARA原则)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The American College of Cardiology, in collaboration with the American Society of Nuclear Cardiology, Heart Rhythm Society, Mended Hearts, North American Society for Cardiovascular Imaging, Society for Cardiovascular Angiography and Interventions, Society for Cardiovascular Computed Tomography, and Society of Nuclear Medicine and Molecular Imaging, recently published a consensus document recommending best practices for the use of ionizing radiation in cardiovascular medicine. With the increase in number and complexity of catheter-based cardiovascular interventions, cardiothoracic anesthesiologists are being requested to consult and provide care for these patients. This review summarizes the salient portions of the consensus document as it pertains to the anesthesiologist. Radiation exposure for both patients and providers should be minimized to be as low as reasonably achievable. For the anesthesiologist involved in the procedure, the authors recommend wearing protective garments including apron, vest, neck collar, and glasses of at least 0.25-mm lead or lead equivalent. The addition of a portable shield also is strongly recommended. The anesthesiologist should maintain the maximum distance allowable from the x-ray source, remembering that radiation intensity is inversely proportional to the square of the distance from the x-ray source. Monitoring radiation exposure is done best by both collar and under-apron film badge. A 0.5-mm lead-equivalent apron is expected to shield approximately 95% of the radiation. By using these recommendations, the anesthesiologist should be able to keep radiation exposure under 20 mSv per year as recommended by the International Commission on Radiation Protection.

来源:J Cardiothorac Vasc Anesth,查看原文。版权归原作者所有。

引用

  1. Hussey P, Wu I, Johnston T, et al. 2018 ACC/HRS/NASCI/SCAI/SCCT Expert Consensus Document on Optimal Use of Ionizing Radiation in Cardiovascular Imaging: Best Practices for Safety and Effectiveness-A Review for the Cardiac Anesthesiologist. J Cardiothorac Vasc Anesth. 2019. PMID: 30979644. doi:10.1053/j.jvca.2019.01.006