双免缝胶带技术:一种减少CT引导介入操作者辐射剂量的免缝胶带新用途
本文介绍一种名为「双免缝胶带技术」的新型安全持针方法,用于CT引导介入时固定骨活检针,避免放射科医师的手靠近X射线束。原文报告本机构在软组织覆盖少或骨病变位于浅表皮质等评估针位置/轨迹较困难的病例中使用该技术,成功率为80%。作者认为该技术是安全有效的针固定方法,介入放射科医师在困难的CT引导骨活检病例中应考虑使用。
要点
- 双免缝胶带技术通过两根免缝胶带(相距2 cm固定于皮肤、90°交叉)固定骨活检针,使操作者手无需靠近X射线束。
- 适用于软组织覆盖少或骨病变位于浅表皮质等针位置/轨迹评估较困难的病例。
- 本机构使用该技术成功率为80%。
核心结论
- 双免缝胶带技术是安全有效的针固定方法,介入放射科医师在困难的CT引导骨活检病例中应考虑使用。
研究设计与样本
- 本研究为技术描述,介绍双免缝胶带技术及其在本机构困难CT引导骨活检病例中的应用经验。
诊断标准与关键数值
- 双免缝胶带技术操作:将一根免缝胶带一端固定于距针皮肤入口点2 cm的皮肤,中段缠绕活检针,另一端固定于针对侧距入口点2 cm的皮肤;第二根免缝胶带以90°方向类似放置。
- 本机构使用该技术成功率为80%。
临床应用与阅片要点
- 作者认为,在软组织覆盖少或骨病变位于浅表皮质的困难CT引导骨活检病例中,可考虑使用双免缝胶带技术固定活检针,以减少操作者手部靠近X射线束。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: We describe a novel and safe needle-holding method that we have termed the 'dual steristrip technique'. This technique can be used to stabilize the bone biopsy needle without the need for the radiologist's hand to be in close proximity to the X-ray beam during CT-guided intervention.
MATERIALS AND METHODS: The dual steristrip technique uses steristrips to stabilize the bone biopsy needle and allows for accurate assessment of needle position and trajectory. This involves affixing one end of a steristrip to the skin 2 cm from the needle skin entry point, wrapping the mid-section of the steristrip around the biopsy needle and affixing the other end of the steristrip to the skin at the opposite side of the needle 2 cm from the needle skin entry point. A second steristrip is then applied in a similar fashion at 90° to the first steristrip.
RESULTS: In our institution, we have used the dual steristrip technique to stabilize the biopsy needle in certain cases where assessment of needle position/trajectory can be more challenging. This includes cases where there is a paucity of soft tissues overlying the bone or if the bone lesion is located in the superficial cortex. We have found it to be successful in 80% of cases.
CONCLUSIONS: The dual steristrip technique is a safe and effective needle stabilization method that should be considered by the interventional radiologist in challenging CT-guided bone biopsy cases.
引用
- McLoughlin E, Iqbal A, Patel A, et al. Dual steristrip technique: a novel use of steristrips to reduce operator radiation dose during CT-guided intervention. Skeletal Radiol. 2019. PMID: 30927033. doi:10.1007/s00256-019-03211-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。