文献速递外周血管介入胸部CTDSA

因肋间肺静脉分流导致大咯血患者经导管栓塞治疗的安全性与疗效

Safety and efficacy of transcatheter embolization in patients with massive hemoptysis due to intercostal pulmonary venous shunts.
PubMed 文献 · Radiol Med · 2019-03-09

这项回顾性研究纳入207例大咯血患者,均行支气管动脉CT血管成像,其中24例(11.6%)存在肋间肺静脉分流综合征。对39支责任肋间动脉行栓塞,37支(94.9%)成功,即刻临床成功22例(91.7%),2例(8.3%)复发咯血,24个月随访仅4例有轻度咯血,效率为75.0%。作者认为用300-500 μm聚乙烯醇颗粒单用或联合微弹簧圈栓塞肋间动脉安全有效。

要点

  • 大咯血患者中肋间肺静脉分流综合征占11.6%(24/207),常合并支气管扩张(54.2%)和结核(25.0%)。
  • 责任肋间动脉栓塞成功率为94.9%(37/39),即刻临床成功率为91.7%(22/24)。
  • 24个月随访仅4例有轻度咯血,效率为75.0%,无皮肤坏死、脊髓动脉栓塞或死亡。

核心结论

  • 用300-500 μm聚乙烯醇颗粒单用或联合微弹簧圈行肋间动脉栓塞,对肋间肺静脉分流所致支气管咯血安全有效。

研究设计与样本

  • 回顾性研究,纳入207例大咯血患者,均行支气管动脉CT血管成像,根据结果行选择性或超选择性数字减影血管造影及栓塞,栓塞剂为300-500 μm聚乙烯醇颗粒或微弹簧圈联合聚乙烯醇颗粒。

关键影像表现/征象

  • 207例大咯血患者中24例(11.6%)存在肋间肺静脉分流综合征。
  • 肋间肺静脉分流患者合并支气管扩张者占54.2%,合并结核者占25.0%。
  • 共对39支责任肋间动脉行栓塞,37支(94.9%)成功栓塞。
  • 37支成功栓塞的动脉中,30支单用聚乙烯醇颗粒栓塞,7支用聚乙烯醇颗粒联合微弹簧圈栓塞。
  • 1例因栓塞剂无法进入肋间动脉而栓塞失败;术中发生动脉夹层时用微弹簧圈栓塞主干动脉。

诊断标准与关键数值

  • 即刻临床成功率为91.7%(22/24),2例(8.3%)咯血复发。
  • 24个月随访期间仅4例出现轻度咯血,效率为75.0%。
  • 未发生皮肤坏死、脊髓动脉栓塞或死亡。

临床应用与阅片要点

  • 对肋间肺静脉分流所致大咯血,可依据分流体积选择300-500 μm聚乙烯醇颗粒单用或联合微弹簧圈行肋间动脉栓塞。
  • 术中发生动脉夹层时,可用微弹簧圈栓塞主干动脉。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Bronchial hemoptysis induced by intercostal pulmonary venous shunt (IPVS) is clinically rare. Pulmonary lesions on pleural surface may facilitate opening of vascular network. This retrospective study investigated safety and efficacy of embolization agents with small-particle embolization treating patients with massive hemoptysis due to IPVS.

METHODS: Patients with massive hemoptysis (n = 207) underwent computed tomography angiography of bronchial artery. Depending on results, selective or superselective digital subtraction angiography and embolization were performed. Polyvinyl alcohol (300-500 μm), or microcoils combined with polyvinyl alcohol, was utilized according to IPVS volume. Vital signs of each patient were closely monitored.

RESULTS: Of 207 patients with massive hemoptysis, 24 (11.6%) had IPVS syndrome. Patients with IPVS had concomitant bronchiectasis (54.2%), followed by tuberculosis (25.0%). Embolizations were performed in 39 culprit intercostal arteries; 37 (94.9%) of these were successfully embolized. Of the latter, 30 and 7 arteries were embolized, respectively, by polyvinyl alcohol alone or polyvinyl alcohol particles combined with microcoils. Embolization failed in one case because the agents could not enter the intercostal artery. If artery dissection occurred during procedure, microcoils were utilized to embolize the main artery. No skin necrosis, spinal artery embolization, or death occurred. Immediate clinical success was achieved in 22 patients (91.7%) after embolization. Two patients (8.3%) experienced recurrence of hemoptysis. Only four patients experienced mild hemoptysis during the 24-month follow-up with the efficiency of 75.0%.

CONCLUSIONS: Intercostal artery embolization with 300-500 μm alone or combined with microcoils is a safe and effective procedure in patients with IPVS-induced bronchial hemoptysis.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Fu Z, Liang Y, Zhao W, et al. Safety and efficacy of transcatheter embolization in patients with massive hemoptysis due to intercostal pulmonary venous shunts. Radiol Med. 2019. PMID: 30852790. doi:10.1007/s11547-019-01020-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。