超声检测经颈静脉肝内门体分流道功能障碍的性能:一项Meta分析
该Meta分析纳入21项研究评估超声检测TIPS功能障碍、狭窄和闭塞的性能,汇总敏感度分别为0.82、0.80和0.96,特异度分别为0.58、0.80和1.00,AUC分别为0.77、0.86和0.95。多数研究使用裸金属支架,结论认为超声对TIPS闭塞性能优异、对狭窄可接受,但多数研究使用裸金属支架,对当前覆膜支架时代的应用受限,覆膜支架背景下检测功能障碍敏感度0.82可接受但特异度0.58有限且LDOR低,需要新的无创工具。
要点
- 超声检测TIPS闭塞汇总敏感度0.96、特异度1.00、AUC 0.95,性能优异。
- 超声检测TIPS功能障碍汇总敏感度0.82、特异度0.58、AUC 0.77,特异度有限。
- 多数研究使用裸金属支架,结论对当前覆膜支架时代的应用受限。
核心结论
- 超声对TIPS闭塞性能优异、对TIPS狭窄性能可接受,但多数研究使用裸金属支架,对当前实践的应用受限;覆膜金属支架背景下超声检测TIPS功能障碍敏感度0.82可接受,但特异度0.58有限、LDOR 1.77低;需要新的无创工具用于覆膜金属支架时代TIPS功能障碍的检测。
研究设计与样本
- Meta分析,共纳入21项研究,检索PubMed、EMBASE、Scopus和Cochrane Library截至2019年2月,计算汇总敏感度、特异度、对数诊断比值比(LDOR)和SROC曲线下面积(AUC),并按超声标准和支架类型进行亚组分析。
诊断标准与关键数值
- 超声检测TIPS功能障碍:汇总敏感度0.82(95%CI 0.67–0.93),特异度0.58(95%CI 0.46–0.70),LDOR 1.77(95%CI 1.20–2.35),AUC 0.77。
- 超声检测TIPS狭窄:汇总敏感度0.80(95%CI 0.69–0.90),特异度0.80(95%CI 0.69–0.91),LDOR 2.83(95%CI 1.88–3.78),AUC 0.86。
- 超声检测TIPS闭塞:汇总敏感度0.96(95%CI 0.92–0.99),特异度1.00(95%CI 0.99–1.00),LDOR 6.28(95%CI 4.96–7.60),AUC 0.95。
临床应用与阅片要点
- 作者认为超声对TIPS闭塞性能优异、对TIPS狭窄性能可接受,但多数研究使用裸金属支架,对当前实践的应用受限。
- 作者认为覆膜金属支架背景下超声检测TIPS功能障碍敏感度0.82可接受,但特异度0.58有限、LDOR 1.77低。
- 作者结论提出需要新的无创工具用于覆膜金属支架时代TIPS功能障碍的检测。
局限性
- 多数研究使用裸金属支架,因此对当前实践的应用受限。
- 作者结论提出需要新的无创工具用于覆膜金属支架时代TIPS功能障碍的检测。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Although ultrasound has been widely used to evaluate transjugular intrahepatic portosystemic shunts (TIPS) patency, several studies have reported conflicting data regarding its performance. Therefore, we aimed to evaluate performance of ultrasound for detection of TIPS dysfunction by performing a meta-analysis.
METHODS: Literature search was performed for studies evaluating ultrasound for TIPS dysfunction, stenosis, and occlusion using PubMed, EMBASE, Scopus, and Cochrane Library through February 2019. Pooled sensitivity, specificity, log diagnostic odds ratio (LDOR), and area under curve (AUC) of summary receiver-operating characteristic were calculated. Subgroup analyses were performed according to ultrasonographic criteria and type of stent.
RESULTS: In total, 21 studies were evaluated. Pooled sensitivity, specificity, and LDOR of ultrasound for detection of TIPS dysfunction were 0.82 (0.67, 0.93), 0.58 (0.46, 0.70), and 1.77 (1.20, 2.35). Pooled sensitivity, specificity, and LDOR for TIPS stenosis were 0.80 (0.69, 0.90), 0.80 (0.69, 0.91), and 2.83 (1.88, 3.78). Pooled sensitivity, specificity, and LDOR for TIPS occlusion were 0.96 (0.92, 0.99), 1 (0.99, 1.00), and 6.28 (4.96, 7.60). AUCs of ultrasound for TIPS dysfunction, stenosis, and occlusion were 0.77, 0.86, and 0.95, respectively.
CONCLUSIONS: Although ultrasound had excellent performance for TIPS occlusion and acceptable performance for TIP stenosis, most studies utilized bare metal stent, and therefore, application to current practice is limited. Ultrasound for TIPS dysfunction in the setting of covered metal stent appeared to have acceptable sensitivity of 0.82, but limited specificity of 0.58 and low LDOR of 1.77. A new noninvasive tool is needed for detection of TIPS dysfunction in the era of covered metal stent.
引用
- Manatsathit W, Samant H, Panjawatanan P, et al. Performance of ultrasound for detection of transjugular intrahepatic portosystemic shunt dysfunction: a meta-analysis. Abdom Radiol (NY). 2019. PMID: 30905044. doi:10.1007/s00261-019-01981-w