文献速递神经外周血管CTUS

双层Roadsaver颈动脉支架相关的支架内再狭窄:一项回顾性单中心研究

In-stent restenosis associated with dual-layer Roadsaver carotid artery stent: a retrospective single-center study.
PubMed 文献 · Radiol Med · 2019-03-02

该回顾性单中心研究纳入13例接受双层Roadsaver颈动脉支架置入的患者,评估12个月随访时支架内再狭窄发生率。2例患者于6个月超声发现<30%再狭窄并于12个月确认,CEUS和MDCT均排除显著狭窄。作者认为Roadsaver支架似乎具有耐久性,但需更长期结局的进一步研究确认。

要点

  • 13例Roadsaver双层颈动脉支架置入,12个月随访未记录到显著支架内再狭窄。
  • 2例患者在6个月DUS发现<30%支架内再狭窄,12个月确认,CEUS和MDCT均排除显著狭窄。

核心结论

  • Roadsaver支架似乎具有耐久性,但需要更长期结局的进一步研究来确认该结果。

研究设计与样本

  • 回顾性单中心研究,13例患者接受Roadsaver颈动脉支架置入,采用多普勒超声(DUS)和多排CT(MDCT)评估颈动脉狭窄,随访12个月评估支架通畅性。

关键影像表现/征象

  • 4例患者收缩期峰值流速(PSV)为130–150 cm/s,6例PSV为150–180 cm/s,3例PSV>180 cm/s。
  • 3例患者记录到<30%的非显著残余狭窄。
  • 2例患者在6个月DUS发现<30%支架内再狭窄,12个月确认,CEUS和MDCT均排除显著狭窄。

诊断标准与关键数值

  • 显著支架内再狭窄:12个月随访未记录到。
  • 非显著支架内再狭窄:2例患者为<30%,经CEUS和MDCT排除显著狭窄。
  • 残余狭窄:3例患者为<30%,为非显著残余狭窄。

临床应用与阅片要点

  • 术后12个月随访中,DUS发现<30%支架内再狭窄时,CEUS和MDCT可用于排除显著狭窄。
  • 术前DUS显示4例PSV 130–150 cm/s、6例PSV 150–180 cm/s、3例PSV>180 cm/s,MDCT提供进一步解剖信息。

局限性

  • 原文为回顾性单中心研究。
  • 作者指出需要更长期结局的进一步研究来确认结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate the incidence of in-stent restenosis (ISR) at 12-month follow-up, in patients treated with new dual-layer Roadsaver (Terumo Corp, Tokyo, Japan) carotid artery stent (CAS).

MATERIALS AND METHODS: Thirteen patients underwent CAS and received a Roadsaver. Neurological examination was performed in all patients. Carotid stenosis was revealed by Doppler ultrasound (DUS) and multidetector CT (MDCT) scan. Four patients presented a peak systolic velocity (PSV) between 130 and 150 cm/s, six a PSV between 150 and 180 cm/s, and three a PSV > 180 cm/s. MDCT gave further anatomic information. Direct stenting was performed in 11 (84.6%) cases, whereas in 2 (15.4%) cases predilatation was required. In all cases postdilatation was performed. Technical and clinical success and safety were evaluated. Stent patency was evaluated during the 12-month follow-up.

RESULTS: Technical success was achieved in all cases. In three patients a nonsignificant residual stenosis < 30% has been reported. No major complications during or after the procedure occurred. One patient (7.7%) showed a transitory bradycardia during angioplasty. One (7.7%) local bleeding at the puncture site treated conservatively occurred. All the neurological examinations performed 24 h and 30 days after the procedure were negative. No significant ISR was registered. In 2 patients, < 30% ISR was revealed at DUS performed after 6 months and confirmed at 12 months. In both patients CEUS and MDCT denied the presence of significant stenosis.

CONCLUSIONS: Roadsaver stent seems to be durable. Further studies with longer-term outcome are necessary to confirm our results.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Ierardi AM, Angileri SA, Brambillasca PM, et al. In-stent restenosis associated with dual-layer Roadsaver carotid artery stent: a retrospective single-center study. Radiol Med. 2019. PMID: 30826921. doi:10.1007/s11547-019-01019-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。