仅使用液体敏感序列的MRI评估2岁以上儿童疑似肌肉骨骼感染
回顾性分析88例连续患儿(90次增强MRI)的疑似肌肉骨骼感染,比较仅液体敏感序列与全增强序列的判读。仅液体敏感序列敏感度100%、特异度61.3%,增强序列敏感度100%、特异度71.0%;所有化脓性关节炎(13例)和骨髓炎(25例)均被识别,阴性预测值100%。仅液体敏感序列的简化MRI方案与增强序列敏感度相同,可用于排除化脓性关节炎和骨髓炎。
要点
- 仅液体敏感序列的简化MRI对儿童肌肉骨骼感染敏感度100%,与增强序列相同。
- 该方案可排除化脓性关节炎和骨髓炎,阴性预测值100%。
- 特异度分别为61.3%(仅液体敏感序列)和71.0%(增强序列),阅片者间一致性好(κ 0.86–1)。
核心结论
- 仅使用液体敏感序列的简化MRI方案在识别儿童肌肉骨骼感染方面与增强序列具有相同的高敏感度,可用于排除化脓性关节炎和骨髓炎。
研究设计与样本
- 回顾性研究,纳入88例连续患者(52例男孩,36例女孩;平均年龄9±4.3岁,范围2–17岁)的90次增强MRI检查,由两名放射科医生分别独立判读仅液体敏感序列和全增强序列,间隔至少1个月;采用Cohen's kappa和百分比一致性比较阅片者间、检查类型间及与临床诊断的一致性。
诊断标准与关键数值
- 仅液体敏感序列评估肌肉骨骼感染的敏感度100%、特异度61.3%,阅片者间一致率84.8%;增强序列敏感度100%、特异度71.0%,阅片者间一致率88.6%;两种检查的阅片者间kappa值均在0.86至1之间;所有化脓性关节炎(13例)和骨髓炎(25例)病例在液体敏感序列上均被判定为可能感染或除非证实否则感染,阴性预测值100%,阅片者间一致率100%。
临床应用与阅片要点
- 作者认为,仅使用液体敏感序列的简化MRI方案可用于评估儿童肌肉骨骼感染,并可排除化脓性关节炎和骨髓炎。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: This study was conducted in order to evaluate whether an MRI protocol with only fluid-sensitive sequences can be used to evaluate for musculoskeletal (MSK) infection of the pelvis and limbs in children.
MATERIALS AND METHODS: This retrospective study analyzed 90 contrast-enhanced (CE) MRI studies from 88 consecutive patients (52 boys and 36 girls; mean age 9 ± 4.3 years; range 2-17) that were performed for the clinical suspicion of MSK infection. Two radiologists reviewed each study twice. The initial study review included only the fluid-sensitive sequences (fluid-sensitive study); the second review, performed at least 1 month later, included all sequences of the contrast-enhanced study (CE study). At each review, anatomic sites of abnormal signal and overall suspicion for infection were recorded. Cohen's kappa and percent agreement were performed to compare agreement between readers, types of studies, and clinical diagnoses.
RESULTS: Interreader agreement for both types of studies had kappa values between 0.86 and 1. For the assessment of MSK infection, the fluid-sensitive study had 100% sensitivity and 61.3% specificity, with 84.8% interreader agreement; and the CE study had 100% sensitivity and 71.0% specificity, with 88.6% interreader agreement. All cases of septic arthritis (13 cases) and osteomyelitis (25 cases) were identified as possible infection or infection until proven otherwise (negative predictive value 100%) with 100% interreader agreement on fluid-sensitive sequences.
CONCLUSION: An abbreviated MRI study using only fluid-sensitive sequences has the same high degree of sensitivity as a CE study to identify MSK infection in children and could be used to exclude septic arthritis and osteomyelitis.
KEY POINTS: • MRI with only fluid-sensitive sequences can be used to evaluate for musculoskeletal infection in children.
引用
- Markhardt BK, Woo K, Nguyen JC, et al. Evaluation of suspected musculoskeletal infection in children over 2 years of age using only fluid-sensitive sequences at MRI. Eur Radiol. 2019. PMID: 30903335. doi:10.1007/s00330-019-06143-6