冠状三维磁共振成像提高山羊脊柱损伤模型中后韧带复合体损伤诊断准确性的研究
研究采用20只新鲜山羊脊柱样本共60个节段,制作椎旁挫伤模型后行T2WI矢状位和冠状位STIR及冠状位和矢状位3D-PDW-SPIR扫描,部分切断棘间韧带后重复扫描。冠状位3D-PDW-SPIR检测棘间韧带撕裂的敏感度、特异度和诊断准确率分别为100%、96.9%和97.9%,显著高于矢状位STIR、冠状位STIR和矢状位3D-PDW-SPIR。作者认为在常规MR方案中加入冠状位3D-PDW-SPIR可能有助于识别邻近挫伤病例中的后韧带复合体损伤。
要点
- 冠状位3D-PDW-SPIR检测棘间韧带撕裂敏感度100%、特异度96.9%、准确率97.9%。
- 冠状位3D-PDW-SPIR诊断准确率显著高于矢状位STIR、冠状位STIR和矢状位3D-PDW-SPIR。
- 各序列检测棘间韧带损伤的观察者间信度均高(kappa 0.776-0.949)。
核心结论
- 与其他MR方法相比,冠状位3D-PDW-SPIR对棘间韧带撕裂的诊断更准确;在常规MR方案中加入冠状位3D-PDW-SPIR可能有助于识别邻近挫伤病例中的后韧带复合体损伤。
研究设计与样本
- 研究采用20只新鲜获取的山羊脊柱样本共60个节段,动物年龄1-1.5岁,雄性8只、雌性12只,性成熟但未达成年体重;经皮向棘间韧带两侧各注射10 mL生理盐水制作椎旁挫伤模型,所有节段在1.5T下行T2WI矢状位和冠状位STIR及冠状位和矢状位3D-PDW-SPIR扫描,之后切断部分棘间韧带并用相同MR技术重复扫描;由两名放射科医生独立评估MR图像,采用kappa系数评估棘间韧带撕裂判读的信度,采用卡方检验比较不同MR技术的诊断准确率。
诊断标准与关键数值
- 冠状位3D-PDW-SPIR检测棘间韧带撕裂的敏感度、特异度和诊断准确率分别为100%、96.9%和97.9%,显著高于矢状位STIR(p=0.000)、冠状位STIR(p=0.000)和矢状位3D-PDW-SPIR(p=0.001);各成像技术检测棘间韧带损伤的观察者间信度均高(0.776-0.949)。
临床应用与阅片要点
- 作者认为,在常规MR方案中加入冠状位3D-PDW-SPIR可能有助于识别邻近挫伤病例中的后韧带复合体损伤。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The purpose of this study was to investigate whether three-dimensional (3D) magnetic resonance imaging could improve diagnostic accuracy for suspected posterior ligamentous complex (PLC) disruption.
MATERIALS AND METHODS: We used 20 freshly harvested goat spine samples with 60 segments and intact surrounding soft tissue. The animals were aged 1-1.5 years and consisted of 8 males and 12 females, which were sexually mature but had not reached adult weights. We created a paraspinal contusion model by percutaneously injecting 10 mL saline into each side of the interspinous ligament (ISL). All segments underwent T2-weighted sagittal and coronal short inversion time inversion recovery (STIR) scans as well as coronal and sagittal 3D proton density-weighted spectrally selective inversion recovery (3D-PDW-SPIR) scans acquired at 1.5T. Following scanning, some ISLs were cut and then the segments were re-scanned using the same magnetic resonance (MR) techniques. Two radiologists independently assessed the MR images, and the reliability of ISL tear interpretation was assessed using the kappa coefficient. The chi-square test was used to compare the diagnostic accuracy of images obtained using the different MR techniques.
RESULTS: The interobserver reliability for detecting ISL disruption was high for all imaging techniques (0.776-0.949). The sensitivity, specificity, and diagnostic accuracy of the coronal 3D-PDW-SPIR technique for detecting ISL tears were 100, 96.9, and 97.9%, respectively, which were significantly higher than those of the sagittal STIR (p = 0.000), coronal STIR (p = 0.000), and sagittal 3D-PDW-SPIR (p = 0.001) techniques.
CONCLUSION: Compared to other MR methods, coronal 3D-PDW-SPIR provides a more accurate diagnosis of ISL disruption. Adding coronal 3D-PDW-SPIR to a routine MR protocol may help to identify PLC disruptions in cases with nearby contusion.
引用
- Zhu X, Wang J, Zhou D, et al. Coronal Three-Dimensional Magnetic Resonance Imaging for Improving Diagnostic Accuracy for Posterior Ligamentous Complex Disruption In a Goat Spine Injury Model. Korean J Radiol. 2019. PMID: 30887746. doi:10.3348/kjr.2018.0632
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。