文献速递骨肌技术与安全USMRDRPET

影像学检查诊断临床诊断的德奎尔万综合征的准确性:系统综述

Diagnostic accuracy of imaging modalities in the detection of clinically diagnosed de Quervain's syndrome: a systematic review.
PubMed 文献 · Skeletal Radiol · 2019-03-19

该系统综述纳入22项研究,汇总超声、磁共振、X线和闪烁扫描对德奎尔万综合征的诊断准确性及影像表现。最常见影像表现为腱鞘积液和支持带增厚,增厚敏感度0.45~1.00、积液敏感度0.29~1.00,但因纳入研究质量所限,诊断准确性无法确定。

要点

  • 最常见影像表现为腱鞘增厚(敏感度0.45~1.00)和积液(敏感度0.29~1.00)。
  • 超声是研究最多的检查方式,可能为临床实践中的首选方式。
  • 因纳入研究质量所限,影像诊断德奎尔万综合征的准确性无法确定。

核心结论

  • 因纳入研究质量所限,影像诊断德奎尔万综合征的准确性无法确定。
  • 超声是研究最多的影像学检查方式,可能为临床实践中的首选方式。

研究设计与样本

  • 系统综述,检索MEDLINE、EMBASE、CINAHL、Cochrane Library、PROSPERO、Web of Science和ProQuest Dissertations & Theses Global共7个数据库。
  • 由两名评价者独立进行筛选、数据提取和质量评价,采用改良的诊断准确性研究质量评价工具第2版(Quality Assessment of Diagnostic Accuracy Studies-2)。
  • 共纳入22项研究,报告了超声、磁共振、X线和闪烁扫描的影像表现。

关键影像表现/征象

  • 报告的影像表现包括腱鞘积液、支持带增厚、皮下水肿、腱鞘炎、血供增多、肌腱增粗、骨侵蚀、骨对合、钙化病灶及闪烁扫描摄取增高。
  • 最常见影像表现位于腱鞘,增厚敏感度0.45~1.00,积液敏感度0.29~1.00。

诊断标准与关键数值

  • 腱鞘增厚诊断德奎尔万综合征的敏感度为0.45~1.00。
  • 腱鞘积液诊断德奎尔万综合征的敏感度为0.29~1.00。

临床应用与阅片要点

  • 超声是研究最多的影像学检查方式,可能为临床实践中的首选方式。
  • 因纳入研究质量所限,影像诊断德奎尔万综合征的准确性无法确定。

局限性

  • 因缺乏报告细节,纳入研究的偏倚风险大多不明确。
  • 因纳入研究质量所限,无法确定影像诊断德奎尔万综合征的准确性。
  • 需要纳入有症状和无症状受试者并明确异常表现定义的研究,以更好地评价影像识别德奎尔万综合征的效果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To collate and synthesise the literature to provide estimates of the diagnostic accuracy of imaging modalities, and summarise the reported imaging findings associated with de Quervain's syndrome.

MATERIALS AND METHODS: A systematic search was performed in seven databases (MEDLINE, EMBASE, CINAHL, Cochrane Library, PROSPERO, Web of Science, and ProQuest Dissertations & Theses Global). Two reviewers independently performed screening, data extraction and quality assessment using a modified Quality Assessment of Diagnostic Accuracy Studies-2. Measures of diagnostic accuracy were summarised for different modalities and imaging findings.

RESULTS: Twenty-two studies were included, reporting ultrasound, magnetic resonance imaging, X-ray and scintigraphy findings. Reported imaging findings included sheath effusion, retinaculum thickening, subcutaneous oedema, tenosynovitis, hypervascularity, increased tendon size, bony erosion, apposition, calcific lesions and increased uptake on scintigraphy. The most commonly reported imaging findings related to the tendon sheath, with a sensitivity ranging from 0.45 to 1.00 for thickening, and 0.29 to 1.00 for effusions. The risk of bias of studies is largely unclear owing to a lack of reported detail.

CONCLUSIONS: The accuracy of imaging in the diagnosis of de Quervain's syndrome is unable to be determined because of the quality of the studies included. Ultrasound is the most frequently studied imaging modality and may be the modality of choice in clinical practice. Further research involving both symptomatic and asymptomatic participants and clear definitions of abnormal findings are required to better evaluate the effectiveness of imaging in identifying de Quervain's syndrome.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. McBain B, Rio E, Cook J, et al. Diagnostic accuracy of imaging modalities in the detection of clinically diagnosed de Quervain's syndrome: a systematic review. Skeletal Radiol. 2019. PMID: 30888457. doi:10.1007/s00256-019-03195-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。