甲状腺影像报告与数据系统之间的异同
研究纳入2011年1月至2016年12月1836例患者共2274个≥1 cm甲状腺结节,回顾性按韩国、美国放射学会(ACR)和欧洲TIRADS分类,比较三系统超声词汇、分类及细针穿刺(FNA)标准的诊断效能;三系统多数超声词汇相似,但分类和FNA标准诊断效能存在显著差异。
要点
- 三系统多数超声词汇相似,仅欧洲TIRADS对混合回声结节回声定义不同。
- 三系统分类间强相关(r=0.777-0.877,均P<0.001),但5、4、3类结节分布差异显著(均P<0.001)。
- 三系统FNA标准的敏感度、特异度及不必要FNA率差异显著(均P<0.001)。
核心结论
- 三系统在多数超声词汇上相似,但分类类别及FNA恶性标准的诊断效能存在显著差异。
研究设计与样本
- 回顾性研究,纳入2011年1月至2016年12月1836例患者共2274个≥1 cm甲状腺结节,按韩国TIRADS、ACR TI-RADS和欧洲TIRADS三种国际学会指南分类。
关键影像表现/征象
- 2274个结节中良性1974个(86.8%),恶性300个(13.2%);所有恶性中93.7%为乳头状癌。
- 三系统多数超声词汇相似,仅欧洲TIRADS对混合回声结节回声定义不同。
诊断标准与关键数值
- 三系统分类间强相关(r=0.777-0.877,均P<0.001)。
- 结节5、4、3类的分类差异显著(均P<0.001)。
- 三系统FNA恶性标准的敏感度、特异度及不必要FNA率差异显著(均P<0.001)。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purposes of this study were to identify the similarities and differences among the Korean Thyroid Imaging Reporting and Data System (TIRADS), American College of Radiology (ACR) TI-RADS, and European TIRADS and to compare the diagnostic performance of sonographic fine-needle aspiration (FNA) criteria for detecting malignant thyroid nodules. MATERIALS AND METHODS. This study included 2274 consecutively evaluated thyroid nodules 1 cm or larger in 1836 patients with final diagnoses from January 2011 to December 2016. US features of the nodules were retrospectively reviewed and classified according to three published guidelines from international societies. We compared the US lexicons, categories, and diagnostic performance of the FNA criteria for malignant nodules among the three reporting systems. RESULTS. Of the 2274 thyroid nodules, 1974 (86.8%) were benign and 300 (13.2%) were malignant; 93.7% of all malignancies were papillary carcinoma. Most of the US lexicons were similar among the three systems except for the definition of echogenicity of a nodule of mixed echogenicity in European TIRADS. Although the categories had strong correlations (r = 0.777-0.877, all p < 0.001) among the three systems, significant differences were observed in categories 5, 4, and 3 of nodules (all p < 0.001) and in the sensitivity, specificity, and rate of unnecessary FNA of the FNA criteria for malignancy (all p < 0.001). CONCLUSION. Although the three systems had similarities in most US lexicons, significant differences were observed in the classified categories and diagnostic performance of the FNA criteria for malignancy.
引用
- Yoon SJ, Na DG, Gwon HY, et al. Similarities and Differences Between Thyroid Imaging Reporting and Data Systems. AJR Am J Roentgenol. 2019. PMID: 30917027. doi:10.2214/AJR.18.20510
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。