文献速递乳腺US

剪切波弹性成像诊断小(≤2 cm)乳腺病灶:附加价值及假性结果相关因素

Shear wave elastography for the diagnosis of small (≤2 cm) breast lesions: added value and factors associated with false results.
PubMed 文献 · Br J Radiol · 2019-03-26

该研究纳入415例连续患者的428个≤2 cm乳腺病灶,比较B型超声、剪切波弹性成像(SWE)及两者联合的诊断效能,并以组织学诊断为参考标准。联合模态的AUC高于B型超声(0.792 vs 0.572,p<0.001),SWE的AUC也高于B型超声(0.718 vs 0.572,p<0.001)。多因素分析显示病灶较小和原位癌与假阴性相关,患者年龄、高危病变、距皮肤或胸壁距离较短及乳腺厚度较深与假阳性相关(均p<0.05)。

要点

  • 在≤2 cm乳腺病灶中,SWE联合B型超声的AUC为0.792,高于单独B型超声的0.572(p<0.001)。
  • SWE单独诊断的AUC为0.718,也高于B型超声的0.572(p<0.001)。
  • 病灶较小和原位癌与SWE假阴性相关,患者年龄、高危病变、病灶距皮肤或胸壁较近及乳腺厚度较深与假阳性相关。

核心结论

  • 在≤2 cm乳腺病灶中,B型超声联合SWE可提高诊断效能;但超声病灶大小、病理类型和病灶位置可能影响SWE取值并导致假性结果。

研究设计与样本

  • 研究纳入2013年8月至2017年2月间415例连续患者的428个≤2 cm乳腺病灶,以组织学诊断为参考标准,比较B型超声、SWE及两者联合的诊断效能,并用多因素logistic回归分析假性SWE结果的相关因素。

诊断标准与关键数值

  • 428个病灶中恶性142个(33.2%)、良性286个(66.8%);联合模态AUC为0.792,高于B型超声的0.572(p<0.001);SWE的AUC为0.718,高于B型超声的0.572(p<0.001)。

临床应用与阅片要点

  • 作者指出,在≤2 cm乳腺病灶中SWE具有诊断价值,但超声病灶大小、病理类型和病灶位置与假性结果相关。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: We compared the diagnostic performance of B-mode ultrasound, shear wave elastography (SWE), and combined B-mode ultrasound and SWE in small breast lesions (≤ 2 cm), and evaluated the factors associated with false SWE results.

METHODS: A total of 428 small breast lesions (≤ 2 cm) of 415 consecutive patients between August 2013 and February 2017 were included. The diagnostic performance of each set was evaluated using the area under the receiver operating characteristic curve (AUC) analysis. Histologic diagnosis was used as reference standard. Multivariate logistic regression analyses identified the factors associated with false SWE results.

RESULTS: Of 428 lesions, 142 (33.2%) were malignant and 286 (66.8%) were benign. The AUC of the combined modality was higher than that of B-mode ultrasound (0.792 vs 0.572, p < 0.001) and that of SWE was higher than that of B-mode ultrasound (0.718 vs 0.572, p < 0.001). Multivariate analysis showed that the smaller lesion size and in situ cancer were associated with false negative, and patient's age, high-risk lesion, shorter distance from the skin or chest wall, and deeper breast thickness were associated with false positive (all p < 0.05).

CONCLUSIONS: The addition of SWE to B-mode ultrasound could improve the diagnostic performance in ≤ 2 cm lesions. However, ultrasound lesion size, pathology, and lesion location are likely to affect the SWE value and result in false results.

ADVANCES IN KNOWLEDGE: Despite the diagnostic usefulness of SWE in small breast lesions (≤ 2 cm), ultrasound lesion size, pathology, and lesion location were associated with false results.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Choi HY, Seo M, Sohn YM, et al. Shear wave elastography for the diagnosis of small (≤2 cm) breast lesions: added value and factors associated with false results. Br J Radiol. 2019. PMID: 30817169. doi:10.1259/bjr.20180341

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。