文献速递乳腺乳腺X线MR

数字乳腺断层摄影对英国乳腺筛查计划中召回女性良性活检率的潜在影响

The Potential Impact of Digital Breast Tomosynthesis on the Benign Biopsy Rate in Women Recalled within the UK Breast Screening Programme.
PubMed 文献 · Radiology · 2019-03-19

本前瞻性单机构研究纳入2015年11月13日至2016年7月29日期间在英国国家卫生服务体系乳腺筛查计划中接受筛查性全视野数字乳腺摄影或乳腺MRI并被召回的女性,评估数字乳腺断层摄影与全视野数字乳腺摄影相比的良性活检率。共827例被分析,全视野数字乳腺摄影检出142例乳腺癌,三联评估无数字乳腺断层摄影时进行571例活检,加入数字乳腺断层摄影后活检数降至298例,癌症检出数保持142例,活检率从69.0%(571/827)降至36.0%(298/827)。

要点

  • 筛查召回女性中,全视野数字乳腺摄影三联评估活检571例(69.0%),加入数字乳腺断层摄影后降至298例(36.0%)。
  • 加入数字乳腺断层摄影后癌症检出数保持142例不变,仅2例为数字乳腺断层摄影单独检出。
  • 本研究为前瞻性单机构研究,数字乳腺断层摄影在筛查后3周内采集。

核心结论

  • 与全视野数字乳腺摄影相比,数字乳腺断层摄影可降低良性活检率,同时维持癌症检出率。

研究设计与样本

  • 前瞻性单机构研究,纳入2015年11月13日至2016年7月29日期间接受筛查性全视野数字乳腺摄影或筛查性乳腺MRI并被召回的827例女性(平均年龄56.7岁±7.7),召回后行乳腺检查、附加影像(乳腺X线、超声)及必要时活检;全视野数字乳腺摄影在筛查时完成,数字乳腺断层摄影在筛查后3周内评估时采集;4名读片者中2名在不了解活检结果的情况下独立分析数字乳腺断层摄影图像,再结合全视野数字乳腺摄影及附加二维乳腺X线或超声图像分析;采用双侧McNemar检验在5%显著性水平比较两种条件的敏感度和特异度。

诊断标准与关键数值

  • 筛查期间30933例女性接受全视野数字乳腺摄影,召回1470例(召回率4.8%),排除后纳入827例;共检出145例乳腺癌(全视野数字乳腺摄影检出142例、数字乳腺断层摄影单独检出2例、监测MRI检出1例);无数字乳腺断层摄影的三联评估进行571例乳腺活检并检出142例癌症,加入数字乳腺断层摄影后进行298例活检并检出142例癌症,活检率从571/827(69.0%)降至298/827(36.0%)。

临床应用与阅片要点

  • 在全视野数字乳腺摄影筛查召回女性的评估中加入数字乳腺断层摄影,可减少良性活检数量并维持癌症检出数;数字乳腺断层摄影在筛查后3周内采集,由不知活检结果的读片者独立及结合全视野数字乳腺摄影分析。

局限性

  • 本研究为单机构研究。
  • 原文未报告其他局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Multiple studies showed digital breast tomosynthesis (DBT) has a higher cancer detection rate and a lower recall rate than full-field digital mammography (FFDM). However, there is a paucity of studies on whether the benign biopsy rate will be lower with DBT. Purpose To evaluate the benign biopsy rate of DBT versus that of FFDM in women recalled after breast screening within the National Health Service Breast Screening Programme. Materials and Methods This prospective single institution study included women who underwent screening FFDM or screening breast MRI between November 13, 2015, and July 29, 2016, and were recalled. Women who were recalled underwent a breast examination, additional imaging (mammography, US), and biopsy, if required. The number of interventions and the outcome of assessment were recorded. FFDM was performed at the screening appointment, and DBT images were acquired when participants attended a screening assessment within 3 weeks after screening FFDM. Two of four readers blinded to biopsy results analyzed DBT images in isolation and then in conjunction with FFDM images and any additional two-dimensional mammographic or US images. Two-tailed McNemar tests were used to test differences in sensitivity and specificity of the two conditions at 5% significance level. Results During the study period, 30 933 women underwent FFDM. A total of 1470 women were recalled (recall rate, 4.8%), and 827 were included after exclusion criteria were applied. Their mean age was 56.7 years ± 7.7 (standard deviation). A total of 145 breast cancers were detected (142 with FFDM, two with DBT only, one with surveillance MRI). Triple assessment without DBT resulted in 571 breast biopsies and enabled detection of 142 cancers. The addition of DBT would have resulted in 298 biopsies and detection of 142 cancers, reducing the number of biopsies from 571 of 827 (69.0%) to 298 of 827 (36.0%). Conclusion When compared with full-field digital mammography, digital breast tomosynthesis can reduce the benign biopsy rate while maintaining the cancer detection rate. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Skaane in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Sharma N, McMahon M, Haigh I, et al. The Potential Impact of Digital Breast Tomosynthesis on the Benign Biopsy Rate in Women Recalled within the UK Breast Screening Programme. Radiology. 2019. PMID: 30888932. doi:10.1148/radiol.2019180809

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。